Welcome to Harvard Apparatus Limited! Login / Register
Search

Search for these keywords
Home Catalogs Online Technical Resources 9/9/2010 4:35:18 GMT My Account
Advanced Search   
Products by Category

Featured Products
Warner Cell Electrophysiology & Cell Biology Research
Hugo Sachs Elektronic Isolated Organ and Tissue Systems
BTX Electroporation and Electrofusion Products
Panlab Behavior Research Products
Hoefer Electrophoresis Products
Coulbourn Instruments
Clark Glass Products
Navicyte Ussing/Diffusion Chambers
Harvard Apparatus
 

Home Syringe Pumps/Peristaltic Pumps Diaphragm Pump


Larger Views

 

Diaphragm Pump

A convenient way to meter, dose, transfer liquids or fill containers in the laboratory, the STEPDOS is resistant to chemical attack, prevents contamination of your pumped medium, and provides the longest possible lifetime when pumping corrosive liquids, gases and vapors. This new microprocessor-controlled metering diaphragm pump is designed for use with neutral and aggressive liquids, without the tubing maintenance disadvantages inherent in peristaltic pumps.
Search for Product in current catalog
Item Listing Full Description Specifications Journal Articles Manuals
Item# Description
720075 STEPDOS Liquid Metering Diaphragm Pump, S Model, Standard Version
720076 STEPDOS Liquid Metering Diaphragm Pump, S Model, Premium Version
720077 STEPDOS Liquid Metering Diaphragm Pump, RC Model, Standard Version
720078 STEPDOS Liquid Metering Diaphragm Pump, RC Model, Premium Version
721669 Threaded Barbed Fittings, Five Pairs of Fittings (1/4-28 UNF Mode) with Barb Sizes: 1/16, 3/32, 1/5, 5/32, and 3/16 inch

For local pricing, contact your nearest distributor.



Full Description Back to Top

• Diaphragm pumps which can be used to meter, dose, and transfer liquids
• Suitable for either corrosive or non-corrosive liquids
• Diaphragm design means there is no tubing to fatigue or break due to wear or corrosion
• Contamination-free operation
• Self-priming
• Can run dry indefinitely, without damage

A convenient way to meter, dose, transfer liquids or fill containers in the laboratory, the STEPDOS is resistant to chemical attack, prevents contamination of your pumped medium, and provides the longest possible lifetime when pumping corrosive liquids, gases and vapors. This new microprocessor-controlled metering diaphragm pump is designed for use with neutral and aggressive liquids, without the tubing maintenance disadvantages inherent in peristaltic pumps.
Unlike traditional pumps, there are neither metal wetted parts to corrode nor tubing to break or fatigue. These pumps are self-priming, maintenance free and will operate dry indefinitely without damage to the pumping mechanism. When operating, you have a choice of languages and the unit is easily programmed. The unique, single-piece molded diaphragm is designed to fit tightly against the pump head, eliminating dead space. The advanced valve design is capable of accurately handling low flow rates, and is not influenced by system pressure fluctuations or tubing fatigue. The multi-purpose STEPDOS metering pump features microprocessor-control for exceptional flexibility and is protected by a case designed to withstand the harshest lab environments.
Unlike other diaphragm pumps on the market today, the STEPDOS has a remarkably smooth flow. This continuous and steady flow, even at low rpm, is accomplished by using a stepper motor that ensures that the suction cycle is completed at a maximum speed, but the output cycle is variably controlled per selected speed. Constant speed changes by the motor and electronic control provide steady output over the entire cycle.
Two basic control packages are available for the STEPDOS. For basic keypad control, choose the S model, which provides easy control of functions using the local touch pad. If you are looking for a more versatile pump, the ‘RC’ model allows you to control the pump remotely using your computer as well as basic keypad control. The ‘RC’ model is supplied with all cables and Windows™ 95 software to allow complete remote control and monitoring of a variety of operating parameters of the pump’s rate from your personal computer.
You also have a choice of chemical resistance. For metering of neutral or mildly aggressive liquids, choose the standard version, which has a combination of wetted materials including PP, FFPM, and PTFE. If highly corrosive liquids are to be metered, the premium version provides the highest corrosion-resistance available in a pump today (wetted materials are a combination of PVDF, FFPM, and PTFE).


Specifications Back to Top

Specifications720075720076720077720078721669
Accuracy±2%±2%±2%±2%NA
Barbed Connections1/16 - 3/16 in barb to 1/4-28 UNF Male1/16 - 3/16 in barb to 1/4-28 UNF Male1/16 - 3/16 in barb to 1/4-28 UNF Male1/16 - 3/16 in barb to 1/4-28 UNF MaleNA
CE MarkEN 61010/EN55011EN 61010/EN55011EN 61010/EN55011EN 61010/EN55011NA
Dimensions (H x W x D) English3.1 x 4.5 x 7.1 in3.1 x 4.5 x 7.1 in3.1 x 4.5 x 7.1 in3.1 x 4.5 x 7.1 inNA
Dimensions (H x W x D) Metric8.0 x 11.5 x 18 cm8.0 x 11.5 x 18 cm8.0 x 11.5 x 18 cm8.0 x 11.5 x 18 cmNA
Flow Rate0.08 to 80 ml/min0.08 to 80 ml/min0.08 to 80 ml/min0.08 to 80 ml/minNA
Max Pressure Head30 PSI30 PSI30 PSI30 PSINA
Motor TypeBipolar stepperBipolar stepperBipolar stepperBipolar stepperNA
Power Consumption100 to 230 VAC, 50/60 Hz100 to 230 VAC, 50/60 Hz100 to 230 VAC, 50/60 Hz100 to 230 VAC, 50/60 HzNA
Repeatability±2%±2%±2%±2%NA
SeriesS - StandardS - PremiumRC - StandardRC - PremiumNA
Tubing Connections1/4-28 UNF Female Thread1/4-28 UNF Female Thread1/4-28 UNF Female Thread1/4-28 UNF Female Thread1/4-28 UNF Female Thread
Weight (kg)1.4 kg1.4 kg1.4 kg1.4 kgNA
Weight (lbs)3 lbs3 lbs3 lbs3 lbsNA

Back to Top



Journal Articles Back to Top

Displaying 21 to 30 of 85 results for Diaphragm Pump   Page 1  2  3  4  5  6  7  8  9 

Score

Document

Description

17% Login to view PP102 Impact of Unilateral Common Iliac Vein Occlusion on Trapping Efficacy of the Greenfiled Filter.pdf
[184 KB]
Cardiovascular Pump use in finding Impact of Unilateral Common lliac Vein Occlusion
17% Login to view PP50 Analysis of Slipstream Flow in a Wide-Necked Basilar Artery Aneurysm.pdf
[136 KB]
Analysis of Slipstream Flow in a Wide-necked Basilar Artery Aneurysm with use of Blood Pump
17% Login to view PP114 Microchannel Devices for Efficient Contacting of Liquids in Solvent Extraction.pdf
[62 KB]
Syringe Infusion Pump use in finding Microchannel Devices for Efficient Contacting of Liquids in Solvent Extraction
17% Login to view PP08 NO Supports Right Ventricular Flow Dominance and Whole Body O2 Utilization in Midgestation Fetal Labms.pdf
[173 KB]
PII: S0022-0728(01)00602-7
15% Login to view PP43 The Measurement of Blood Flow from Dynamic Digital X-Ray Images Using a Weighted Optical Flow Algorithm.pdf
[202 KB]
Pulsatile Syringe Pump use in finding The Measurement of Blood Flow from Dynamic Digital X-Ray Images Using a Weighted Optical Flow Algorithm
15% Login to view PP59 Characterization of N-Glycans from Arabidopsis.pdf
[264 KB]
Syringe Pump use in Characterization of N-Glycans from Arabidopsis Application to a Fucose-Deficient Mutant
15% Login to view PP73 A Set-Point Model with Oscillatory Behavior Predicts the Time Course of 8-OH-DPAT-Induced Hypothermia.pdf
[610 KB]
Harvard 22 Syringe Pump use in finding set-point model with oscillatory behavior predicts the time course of 8-OH-DPAT-induced hypothermia
15% Login to view PP108 Effects of Chemotherapy.pdf
[122 KB]
Infusion Pump use in finding Effects of Chemotherapy by 1,3-Bis(2-chloroethyl)-1-nitrosourea
15% Login to view PP66 Characterization of a Novel Sepia officinalis Neuropeptide Using MALDI-TOF MS and Post-Source Decay Analysis.pdf
[208 KB]
Characterization of a novel Sepia officinalis neuropeptide with use of a Syringe Pump
15% Login to view PP111 Development of Response Timing and Direction Selectivity in Cat Visual Thalamus and Cortex.pdf
[248 KB]
Syringe Pump use in Production of small molecular weight catalysts
   

Back to Top



Manuals Back to Top

Displaying 1 to 3 of 3 results for Diaphragm Pump  

Score

Document

Description

100% Login to view Nanoleader Pump Series NLS110P Pressure Pump Manual.pdf
[2.2 MB]
705000 NLS110P Pump Manual
71% Login to view Pump Selection Guide.pdf
[263 KB]
DC1_A_Pumps.qxd
57% Login to view 703005 PHD ULTRA Manual.pdf
[2.4 MB]
PHD Ultra Syringe Pumps Manual - Standard/Remote/Programmable
   

Back to Top

Announcing the new
PHD ULTRA™ Syringe Pumps

Click here for more information about PHD ULTRA™ Syringe Pumps and to download a brochure.

  • Patent pending mechanical design provides highest accuracy/precision & smoothest flow
  • Easy operation with advanced touch screen
  • Advanced EZ PRO™ software for PC functions without a PC.


Sign-up for a FREE Full Line Bioresearch Catalog
CLICK HERE!

  • Over 11,000 specialty products to enhance your bioresearch
  • Enhanced solutions for small animal research
  • 100's of pages of specialized information on instrumentation, applications, uses of products

  Privacy Policy   |   Terms and Conditions   
Copyright© Harvard Apparatus Ltd. - All rights reserved.
(44) 1732-864001
Website-related comments or concerns can be emailed to our webmaster.

Anesthesia Equipment Animal Handling Products Behavior Research Products Biological Measurement Products Cardiovascular Products Cell Biology Products Microincubation / Microinjectors CPK® Atomic Models Delivery & Sampling Products Dialysis / Sample Prep / SPE Electroporation / Transfection Electrophysiology Products General Laboratory Products Homeothermic/Temperature Control Isolated Organ & Isolated Tissue Molecular Biology Products Neuroscience Products Non-Invasive Blood Pressure Physiology Products Respiratory Products Stereotaxic Instruments Surgical Equipment Surgical Instruments Syringe Pumps/Peristaltic Pumps Tubing & Connectors Ventilators