Welcome to Harvard Apparatus Limited! Login / Register
Search

Search for these keywords
Home Catalogs Online Technical Resources My Account
Advanced Search   
Products by Category

Featured Products
Warner Cell Electrophysiology & Cell Biology Research
Hugo Sachs Elektronic Isolated Organ and Tissue Systems
BTX Electroporation and Electrofusion Products
Panlab Behavior Research Products
Hoefer Electrophoresis Products
Coulbourn Instruments
Clark Glass Products
Navicyte Ussing/Diffusion Chambers
CMA
Harvard Apparatus
 

Home Standard Infuse/Withdraw Harvard Pump 11 Plus Advanced Single Syringe with Dual RS-232 Syringe Pumps


Larger Views

 

Standard Infuse/Withdraw Harvard Pump 11 Plus Advanced Single Syringe with Dual RS-232 Syringe Pumps

The Pump 11 Plus family of pumps are our more basic pumps, but provide the precision flow that Harvard Apparatus pumps are known for. Select from either 1 or 2 syringe models and from basic infusion only or the more advanced infuse/withdraw models. The infuse/withdraw models also have RS-232 communictions.
Search for Product in current catalog
Item Listing Full Description Specifications Journal Articles Manuals
Item# Description
702211 Harvard Pump 11 Plus Advanced Single Syringe with Dual RS-232
702212 Harvard Pump 11 Plus Advanced Dual Syringe with Dual RS-232

For local pricing, contact your nearest distributor.



Full Description Back to Top

• NEW brighter display: easier to read and use
• NEW volume dispense feature
• Single or dual syringe models available
• Small, compact size

Harvard Apparatus’ Syringe Pump 11 Plus combines smoother flow and updated features to create a high performance syringe pump with a basic syringe pump price!

Bright Display and Easy-To-Use Interface
A new, two-line 16 character vacuum fluorescent display and six membrane keys make this a powerful, easy-to-use syringe pump. Only two entries are required to start pumping; Syringe ID and flow rate. The flow rate can be changed while the pump is running.

Two Modes of Operation,
Constant Flow Rate & Volume Dispense
The new Pump 11 Plus will operate continuously in RATE mode or accurately dispense a specific amount of fluid in VOLUME mode.

Versatile
Select from two different models. The standard Pump 11 Plus model has the following features:
• Infusion Only
• End of Travel Limit Stop
• Anti-Siphon Bracket

The Pump 11 Plus Advanced model has the same features as the standard model, but also includes:
• Infusion/Withdrawal
• Dual RS-232 Communications

Both models are available with either a single syringe configuration or dual syringe configuration. Select the pump that best fits your application.

Non-Volatile Memory
New micro-stepping pump profiles deliver very smooth and consistent flow over the entire flow rate range. These pumps now feature non-volatile memory. The pump remembers its last syringe size, flow rate used and configuration settings. An advanced universal power supply means there is no need to change AC line switches, fuses or wires.

The new Pump 11 Plus will operate on any AC line voltage from 95 VAC to 240 VAC, either 50 or 60 Hz. The new Pump 11 Plus offers the same power failure mode as our PHD 22/2000 syringe pump series. In a power failure the pump can either Resume or Stop pumping when power is returned.

Safety
The Pump 11 Plus motor will not shut itself off in case of overload, rather it will remain in a stalled position with no damage. An adjustment collar on the guide rod prevents the syringe plunger from hitting bottom.

CE Mark Approved
The new Pump 11 Plus meets all relevant European EMC and Safety requirements for laboratory equipment..


Specifications Back to Top

Specifications702211702212
TypeMicroprocessor single or dual syringe, infusion only or infuse/withdrawMicroprocessor single or dual syringe, infusion only or infuse/withdraw
Pump ConfigurationStandardStandard
Pump FunctionInfuse/WithdrawInfuse/Withdraw
Flow Rate Minimum0.0014 l/hr0.0014 l/hr
Flow Rate Maximum26.56 ml/min7.909 ml/min
# of Syringes12
Syringe Rack TypeStandard RackStandard Rack
Syringe Size Minimum0.5 l0.5 l
Syringe Size Maximum60 ml10 ml
Average Linear Force16 lbs16 lbs
PressureLowLow
Communications Level11
CommunicationsRS-232RS-232
Accuracy+/- 0.5 %+/- 0.5 %
Reproducibility+/- 0.1 %+/- 0.1 %
Non Volatile MemoryStorage of all settingsStorage of all settings
RS-232OptionOption
TTLNoNo
Motor1/4 microstepping, 0.9 micro step angle motor1/4 microstepping, 0.9 micro step angle motor
Motor Stepper 1 Revolution of Lead Screw3,200 at 1/4 stepping3,200 at 1/4 stepping
Step Rate Minimum6.8 sec/step6.8 sec/step
Step Rate Maximum416.7 sec/step416.7 sec/step
Step Resolution0.8 m/step0.8 m/step
Pusher Travel Rate Minimum2.9068 m/min2.9068 m/min
Pusher Travel Rate Maximum47.6 mm/min47.6 mm/min
DisplayVacuum fluorescent, 2-line, 16 characterVacuum fluorescent, 2-line, 16 character
Input Power12 VDC, 1.5 A, 18 W12 VDC, 1.5 A, 18 W
Voltage RangeUniversal input 100/250 VAC, 50/60 Hz, 18 W (use only Harvard Apparatus approved supply and line cord)Universal input 100/250 VAC, 50/60 Hz, 18 W (use only Harvard Apparatus approved supply and line cord)
Height Metric13 cm13 cm
Height English5 in5 in
Width Metric22.9 cm22.9 cm
Width English9 in9 in
Depth Metric11.4 cm11.4 cm
Depth English4.5 in4.5 in
Net Weight Metric2.1 kg2.1 kg
Net Weight English4.6 lb4.6 lb

Back to Top



Journal Articles Back to Top

Displaying 1 to 10 of 128results for Standard Infuse/Withdraw Harvard Pump 11 Plus Advanced Single Syringe with Dual RS-232 Syringe Pumps   Page 1  2  3  4  5  6  7  8  9  10  11  12  13 

Score

Document

Description

100% Login to view PP100 Nonstriatal Dopamine D1 Receptors Regulate Striatal Acetylcholine Release In Vivo.pdf
[215 KB]
Double Syringe Pump use in finding Effects of hyperglycemia
92% Login to view PP103 Polynuclear Complexes of Copper I and the 2-3-5-Pyrazolyl-6-methylpyridine Ligand.pdf
[253 KB]
Defining Extracellular Integrin Chain Sites That Affect Cell Adhesion and Adhesion Strengthening without Altering Soluble Ligand Binding
90% Login to view PP99 Microcirculation in Intestinal Villi.pdf
[211 KB]
Syringe Pump use in finding Microcirculation in Intestinal Villi
88% Login to view PP06 Molecular Clocks.pdf
[108 KB]
PHD 22/2000 Syringe Pump used in finding Molecular Clocks
86% Login to view PP83 Design and Implementation of A Rapid-Mixer Flow-Cell For Time-Resolved Infrared Microspectroscopy.pdf
[124 KB]
Design and implementation of a rapid-mixer flow-cell for time-resolved infrared microspectroscopy
83% Login to view PP45 Precision Alignment Packaging for Microsystems with Multiple Fluid Connections.pdf
[301 KB]
Union of capillary high-performance liquid chromatography
81% Login to view PP28 Electrospray Ionization Tandem Mass Spectrometric Study of Salt Cluster ions.pdf
[422 KB]
Electrospray ionization tandem mass spectrometric study of salt cluster ions with use of Model 11 syringe pump
78% Login to view PP48 Episodic Coronary Artery Vasospasm and Hypertension Develop in the Absence of Sur2 Katp Channels.pdf
[673 KB]
Episodic coronary artery vasospasm and hypertension develop in the absence of Sur2 Katp channels
74% Login to view PP91 Enhancement of 3,4-Methylenedioxymethamphetamine Neurotoxicity by the Energy Inhibitor Malonate.pdf
[352 KB]
Enhancement of 3,4-methylenedioxymethamohetamine neurotoxicity by the energy inhibitor malonate
73% Login to view PP109 Measurement of Intravascular Na+ During Increased CBF Using 23Na NMR with a Shift Reagant.pdf
[135 KB]
Infusion Pump use in finding Measurement of intravascular Na+ during increased CBF using 23Na NMR with a shift reagent
   

Back to Top



Manuals Back to Top

Displaying 1 to 4 of 4results for Standard Infuse/Withdraw Harvard Pump 11 Plus Advanced Single Syringe with Dual RS-232 Syringe Pumps  

Score

Document

Description

100% Login to view Pump11 Plus.pdf
[1.1 MB]
Model 11 Plus Syringe Pump Manual
93% Login to view 11 Elite Syringe Pump User Manual.pdf
[3.2 MB]
Pump 11 Elite User Manual
71% Login to view 703005 PHD ULTRA Manual.pdf
[2.4 MB]
PHD Ultra Syringe Pumps Manual - Standard/Remote/Programmable
52% Login to view 703005 PHD ULTRA Quickstart.pdf
[173 KB]
PHD Ultra Syringe Pumps Quickstart Guide - Standard/Remote/Programmable
   

Back to Top

Breakthrough Products for Regenerative Medicine
2011 Regenerative Medicine Brochure
100's of Innovative products developed with leading scientists & surgeons!
  • Injection & Perfusion
  • Bioreactors
  • Biosensing
  • Total Solutions
  • Total Support


Announcing the new
PHD ULTRA™ Syringe Pumps

Click here for more information about PHD ULTRA™ Syringe Pumps and to download a brochure.

  • Patent pending mechanical design provides highest accuracy/precision & smoothest flow
  • Easy operation with advanced touch screen
  • Advanced EZ PRO™ software for PC functions without a PC.


Sign-up for a FREE Full Line Bioresearch Catalog
CLICK HERE!

  • Over 11,000 specialty products to enhance your bioresearch
  • Enhanced solutions for small animal research
  • 100's of pages of specialized information on instrumentation, applications, uses of products

 

Products on this website are for Research Use Only. Not for use in humans unless
proper investigational device regulations have been followed.


Privacy Policy   |   Terms and Conditions   
Copyright© Harvard Apparatus Ltd. - All rights reserved.
(44) 1732-864001
Website-related comments or concerns can be emailed to our webmaster.

Anesthesia Equipment Animal Handling Products Behavior Research Products Biological Measurement Products Cardiovascular Products Cell Biology Products Microincubation / Microinjectors CPK Atomic Models Delivery & Sampling Products Dialysis / Sample Prep / SPE Electroporation / Transfection Electrophysiology Products General Laboratory Products Homeothermic/Temperature Control Isolated Organ & Isolated Tissue Molecular Biology Products Neuroscience Products Non-Invasive Blood Pressure Physiology Products Respiratory Products Stereotaxic Instruments Surgical Equipment Surgical Instruments Syringe Pumps/Peristaltic Pumps Tubing & Connectors Ventilators