Welcome to Harvard Apparatus Limited! Login / Register
Search

Search for these keywords
Home Catalogs Online Technical Resources My Account
Advanced Search   
Products by Category

Featured Products
Warner Cell Electrophysiology & Cell Biology Research
Hugo Sachs Elektronic Isolated Organ and Tissue Systems
BTX Electroporation and Electrofusion Products
Panlab Behavior Research Products
Hoefer Electrophoresis Products
Coulbourn Instruments
Clark Glass Products
Navicyte Ussing/Diffusion Chambers
CMA
Harvard Apparatus
 

Home Syringe Pumps/Peristaltic Pumps Shuttle Pump


Larger Views

 

Shuttle Pump

This Shuttle Pump is based on a patented dual-channel shuttle pump mechanism that can deliver flow rates up to 50 ml/min, but is small and incredibly power efficient. This unique pump was designed for cell culture experiments conducted on the Space Shuttle, where weight and power consumption are significant constraints.
Search for Product in current catalog
Item Listing Full Description Specifications Journal Articles Manuals
Item# Description
610128 Harvard Apparatus Shuttle Pump, 120 VAC
720011 Harvard Apparatus Shuttle Pump, 220 VAC

For local pricing, contact your nearest distributor.



Full Description Back to Top

• Battery powered
• Perfect for cell culture work
• Fits in palm of your hand
• Flow rates up to 50 ml/minute
• Extremely energy efficient
• Gentle pulsatile flow
• Extended tubing life

This Shuttle Pump is based on a patented dual-channel shuttle pump mechanism that can deliver flow rates up to 50 ml/min, but is small and incredibly power efficient. This unique pump was designed for cell culture experiments conducted on the Space Shuttle, where weight and power consumption are significant constraints.
Efficient Design
This fluid pump uses two easily removable pumping chambers on either side of an oscillating shuttle. The balanced tube arrangement, high-efficiency motor, and 4 passive check valves result in a pump that is far more efficient than a typical peristaltic pump: 13 times higher flow rates with 60% lower weight and 90% lower power consumption.
Gentle Pumping Action
The oscillating shuttle does not squeeze the tubes to occlusion, making this device ideal for pumping cell suspensions and blood. Fluid can free flow through the pump in the forward direction, simplifying filling and purging, but limiting applications to those where outflow pressure is greater than inflow pressure. Single or dual channel operation. Join the two tubes to form a single input and output and thereby generate twice the flow rate with less pulsation.
Built-In Control Circuitry
Adjust the motor speed over a 20:1 range using the knob on the top of the pump.
OEM
The pump mechanism is also available for OEM applications.
Please call Harvard Apparatus for details


Specifications Back to Top

Specifications610128720011
OD (mm)3.4 mm3.4 mm
OD (inch)0.135 in0.135 in
Dimensions (H x W x D) Metric3.3 x 11.4 x 7.2 cm3.3 x 11.4 x 7.2 cm
Dimensions (H x W x D) English1.3 x 4.5 x 2.8 in1.3 x 4.5 x 2.8 in
Flow Rate Both Tubes Combined2.5 to 50 ml/min (no back pressure)2.5 to 50 ml/min (no back pressure)
Flow Rate Single Tube1.25 to 25 ml/min (no back pressure)1.25 to 25 ml/min (no back pressure)
Flow WaveformPulsatilePulsatile
Pumping Chambers2 per pump2 per pump
Pulses per Minute~ 45 at 6 ml/min (single channel)~ 45 at 6 ml/min (single channel)
Developed Pressure9 PSI (flow = 0), maximum9 PSI (flow = 0), maximum
Tubing Life> 3 months> 3 months
Power Source Provided9 V battery and AC adapter9 V battery and AC adapter
Battery Life50 hrs under continuous operation, 9 V lithium50 hrs under continuous operation, 9 V lithium

Back to Top



Journal Articles Back to Top

Displaying 1 to 10 of 90results for Shuttle Pump   Page 1  2  3  4  5  6  7  8  9 

Score

Document

Description

100% Login to view PP114 pump microchannel.pdf
[74 KB]
Syringe Infusion Pump use in finding Microchannel Devices for Efficient Contacting of Liquids in Solvent Extraction
99% Login to view PP04 pump ms.pdf
[53 KB]
Analysis of Jojoba Oil with syringe pump 'apparatus 22'
92% Login to view VT24 Pump Ventilator.pdf
[90 KB]
Intramucosal-arterial Pco2 gap fails to reflect intestinal dysoxia in hypoxic hypoxia
89% Login to view PP08 Mechanical Pump 901A.pdf
[188 KB]
Mechanical Pump use in finding NO supports right ventricular flow dominance
89% Login to view PP96 22 pump eq.pdf
[944 KB]
Syringe Pump use in finding Intrarenal Dopamine Production and Distrobution in the Rat
88% Login to view PP57 Respiratory Pump 57.pdf
[209 KB]
Respirator pump use in finding Quantification of Cerebral Perfusion With "Real Time" Contrast-Enhanced Ultrasound
85% Login to view PP13 Pump 22 Syringe.pdf
[646 KB]
Syringe Pump use in finding A set-point model with oscillatory behavior predicts the time course of 8-OH-DPAT-induced hypothermia
85% Login to view PP12 Pump 11 Syringe.pdf
[179 KB]
Syringe Pump use in Studies of potential-dependent metallothionein adsorptions using a low-volume electrochemical quartz crystal microbalance flow cell
76% Login to view PP50 Blood Pump Model 1421.pdf
[141 KB]
Analysis of Slipstream Flow in a Wide-necked Basilar Artery Aneurysm with use of Blood Pump
71% Login to view PP23 pump ms sciex.pdf
[135 KB]
Synthesis, crystal structure and electrospray ionisation mass spectrometry of a novel one-dimensional cyano-bridged Ni(ii)-Au(i) polymer
   

Back to Top



Manuals Back to Top

Displaying 1 to 4 of 4results for Shuttle Pump  

Score

Document

Description

100% Login to view Pump Selection Guide.pdf
[263 KB]
DC1_A_Pumps.qxd
58% Login to view Harvard Peristaltic Pump Brochure.pdf
[1.6 MB]
Harvard Peristaltic Pump Brochure
56% Login to view 11 Elite Syringe Pump User Manual.pdf
[3.2 MB]
Pump 11 Elite User Manual
51% Login to view Nanoleader Pump Series NLS110P Pressure Pump Manual.pdf
[2.2 MB]
705000 NLS110P Pump Manual
   

Back to Top

Get Rolling & Infuse Savings
...on Surgical Solutions and Syringe Pumps!
Get rolling and infuse savings
For special end-of-year offers such as savings on Surgical Solutions and information on how to get a FREE Hamilton 1000 Series GASTIGHT® PTFE Luer Lock Syringe.


Announcing the new
PHD ULTRA™ Syringe Pumps

Click here for more information about PHD ULTRA™ Syringe Pumps and to download a brochure.

  • Patent pending mechanical design provides highest accuracy/precision & smoothest flow
  • Easy operation with advanced touch screen
  • Advanced EZ PRO™ software for PC functions without a PC.


Sign-up for a FREE Full Line Bioresearch Catalog
CLICK HERE!

  • Over 11,000 specialty products to enhance your bioresearch
  • Enhanced solutions for small animal research
  • 100's of pages of specialized information on instrumentation, applications, uses of products

 

Products on this website are for Research Use Only. Not for use in humans unless
proper investigational device regulations have been followed.


Privacy Policy   |   Terms and Conditions   
Copyright© Harvard Apparatus Ltd. - All rights reserved.
(44) 1223-423723
Website-related comments or concerns can be emailed to our webmaster.

Anesthesia Equipment Animal Handling Products Behavior Research Products Biological Measurement Products Cardiovascular Products Cell Biology Products Microincubation / Microinjectors CPK® Atomic Models Delivery & Sampling Products Dialysis / Sample Prep / SPE Electroporation / Transfection Electrophysiology Products General Laboratory Products Homeothermic/Temperature Control Isolated Organ & Isolated Tissue Molecular Biology Products Neuroscience Products Non-Invasive Blood Pressure Physiology Products Respiratory Products Stereotaxic Instruments Surgical Equipment Surgical Instruments Syringe Pumps/Peristaltic Pumps Tubing & Connectors Ventilators