Welcome to Harvard Apparatus Limited! Login / Register
Search

Search for these keywords
Home Catalogs Online Technical Resources My Account
Advanced Search   
Products by Category

Featured Products
Warner Cell Electrophysiology & Cell Biology Research
Hugo Sachs Elektronic Isolated Organ and Tissue Systems
BTX Electroporation and Electrofusion Products
Panlab Behavior Research Products
Hoefer Electrophoresis Products
Coulbourn Instruments
Clark Glass Products
Navicyte Ussing/Diffusion Chambers
CMA
Harvard Apparatus
 

Home Cell Biology Products Spill Detection System


Larger Views

 

Spill Detection System

Warner Instruments is pleased to introduce a new product designed to detect leaks on your microscope before they cause a problem! The OS-250 Overflow/Spill provides a simple and effective method for detecting leaks and spills around sensitive equipment (such as a microscope). The integrated switched power controller can be used to rapidly turn off all pump and perfusion systems in the event of a spill. When assembled, the OS-250 can respond to as few a 3 drops of liquid.
Search for Product in current catalog
Item Listing Full Description Specifications Journal Articles Manuals
Item# Description
641520 Over Flow Sensor with 4 Fibretec Mats and Cable
641522 Over Flow Sensor Replacement Moisture Sensing Mats, pkg. of 4
641523 Over Flow Sensor Replacement Moisture Sensing Mats and Cable

For local pricing, contact your nearest distributor.



Full Description Back to Top

• Prevent Costly Downtime
• Easy to install
• Compatible with upright and inverted microscopes
• As little as 3 drops of liquid will cause the OS-250 to react
• Easy to install

Features include:
• Cut-able moisture sensitive mats
• Audible and visual alarms
• 8 A switched power supply
• Rapid response to liquid exposure
• Quiet operation

The OS-250 System is designed to detect spills around sensitive equipment and to take preventitive action if able. The system includes special moisture-sensitive mats consisting of material specifically developed for detecting liquid spills. A simple electrical connection between the moisture-sensitive mat and our OS-250 Controller sets the alarm. When as little as three drops of water touches the mat an audible alarm is triggered and an LED starts flashing.

In addition to sounding an alarm, the OS-250 Controller can turn the power off to any device that is plugged into its single, switched power outlet. The power outlet of the OS-250 controller can supply up to 10 A of current and will easily control syringe pumps or valve controllers. The photo above shows a rear view of the OS-250 controller box.

The OS-250 System is supplied with four 30 X 30 cm moisture-sensitive mats that can be cut to any size or shape using sharp scissors or a straightedge.


Specifications Back to Top

Specifications641520641522641523
ModelOS-250MAT-1MAT-2
Detection Volume1 to 3 drops  
Enclosure Dimensions (H x W x D) Metric4.6 x 8.2 x 18.0 cm  
Dimensions (H x W x D) English1.8 x 3.2 x 7.1 in  
Weight Metric1.4 kg  
Weight English3.1 lb  
Power Requirements90 - 240 VAC, 50/60 Hz, 0.5 VA  
Operating Humidity10 - 75%  
Switched Outlet current8 Amps  

Back to Top



Journal Articles Back to Top

Displaying 1 to 10 of 18results for Spill Detection System   Page 1  2 

Score

Document

Description

100% Login to view NO02 hearing.pdf
[518 KB]
The Electrochemical and fluorescene detection of nitric oxide in the cochlea and its increase following loud sound
49% Login to view TD0160 1.PDF
[348 KB]
Isotomic Transducer use in Stabilization of Temporally Summated Muscle Contractions in the Lobster (Panulirus) Pyloric System
26% Login to view Permeation and Activation of the M2 Ion Channel.PDF
[248 KB]
Permeation and Activation of the M2 Ion Channel of Influenza A Virus with use of Fast Step Perfusion System
25% Login to view HS15 Myoglobin facilitates oxygen diffusion.pdf
[631 KB]
Isolated Heart Apparatus use in Myoglobin facilitating oxygen diffusion
25% Login to view WR19FA 1.PDF
[220 KB]
Permeation and Activation of the M2 Ion Channel of Influenza A Virus with use of Fast Step Perfusion System
23% Login to view PP33PR 1.PDF
[393 KB]
Micro/nano spacecraft thermal control using a MEMS-based pumped liquid cooling system with use of Programmable syringe pump
23% Login to view WR04PL 1.PDF
[495 KB]
Two Distinct Ca2+ - Dependent Signaling Pathways regulate the Motor Output of Cochlear Outer Hair Cells with Pneumatic Injection System
20% Login to view Action of 2,3-butanedione monoxime on capacitance.PDF
[352 KB]
Pneumatic Injection System use in finding Action of 2,3-butanedione monoxime on capacitance and electromotility of guinea-pig cochlear outer hair cells
20% Login to view WR03PL 1.PDF
[344 KB]
Pneumatic Injection System use in finding Action of 2,3-butanedione monoxime on capacitance and electromotility of guinea-pig cochlear outer hair cells
20% Login to view Regulate the Motor Output of Cochlear Outer Hair Cells.PDF
[504 KB]
Two Distinct Ca2+ - Dependent Signaling Pathways regulate the Motor Output of Cochlear Outer Hair Cells with Pneumatic Injection System
   

Back to Top



Manuals Back to Top

Displaying 1 to 1 of 1result for Spill Detection System  

Score

Document

Description

100% Login to view OS250 Spill Detection Manual.pdf
[204 KB]
Warner Instrument Corporation
   

Back to Top

Ussing System Guide from Warner

Warner Instruments is pleased to present our comprehensive Ussing System Guide. The Guide discusses the theory of operation and presents the largest collection of Ussing Systems available.

  • Classic, Self-Contained, NaviCyte Vertical, NaviCyte Horizontal, and EasyMount Chambers
  • Amplifier packages supporting from 1 to 8 chambers
  • Dedicated data acquisition packages supporting up to 8 chambers
  • A self-contained 8-channel amplifier-computer-software package is also available
  • Full complement of accessories and supplies

NEW
Breakthrough Products for Regenerative Medicine
2011 Regenerative Medicine Brochure
100's of Innovative products developed with leading scientists & surgeons!
  • Injection & Perfusion
  • Bioreactors
  • Biosensing
  • Total Solutions
  • Total Support


Announcing the new
PHD ULTRA™ Syringe Pumps

Click here for more information about PHD ULTRA™ Syringe Pumps and to download a brochure.

  • Patent pending mechanical design provides highest accuracy/precision & smoothest flow
  • Easy operation with advanced touch screen
  • Advanced EZ PRO™ software for PC functions without a PC.


Sign-up for a FREE Full Line Bioresearch Catalog
CLICK HERE!

  • Over 11,000 specialty products to enhance your bioresearch
  • Enhanced solutions for small animal research
  • 100's of pages of specialized information on instrumentation, applications, uses of products

 

Products on this website are for Research Use Only. Not for use in humans unless
proper investigational device regulations have been followed.


Privacy Policy   |   Terms and Conditions   
Copyright© Harvard Apparatus Ltd. - All rights reserved.
(44) 1732-864001
Website-related comments or concerns can be emailed to our webmaster.

Anesthesia Equipment Animal Handling Products Behavior Research Products Biological Measurement Products Cardiovascular Products Cell Biology Products Microincubation / Microinjectors CPK® Atomic Models Delivery & Sampling Products Dialysis / Sample Prep / SPE Electroporation / Transfection Electrophysiology Products General Laboratory Products Homeothermic/Temperature Control Isolated Organ & Isolated Tissue Molecular Biology Products Neuroscience Products Non-Invasive Blood Pressure Physiology Products Respiratory Products Stereotaxic Instruments Surgical Equipment Surgical Instruments Syringe Pumps/Peristaltic Pumps Tubing & Connectors Ventilators