• Independent V Hold and I Hold • Stability in Current Clamp with selection of three I Clamp response speeds • 4-Pole low-pass Bessel filter • Internal generated test signals • Zap circuit with variable duration • 3 year warranty
The PC-501A Patch Clamp is a “workhorse” equally at home in research and teaching labs. Most single channel and whole cell studies are easily handled with this modestly priced instrument. With a choice of four headstages, a wide range of patch, whole cell and bilayer applications are covered. Its value is further enhanced by a 3-year warranty. Headstage Choices Four resistive-feedback headstages are available for the PC-501A: • 5101-10G (10 G?) headstage for recording single channel currents up to ±1 nA. Noise level measured at 1 kHz is 60 fA. • 5101-01G (1 G?) headstage for whole cell studies with currents to ±10 nA. • 5101-100M (100 M?) headstage for whole cell studies with currents to ±100 nA. • 5101-10GB (10 G?) headstage modified for bilayer capacitances up to 250 pF. Maximum current is ±1 nA. Operating Modes • V Clamp Mode: Input is clamped to a maximum of ±1 volt. Commands are the sum of the holding voltage and any external input signals. • Zero Current Mode: Bridges the voltage and current clamp modes. All commands are inactive except the junction zero, which functions in this case as an offset control for the electrode and tip potentials associated with the pipette. • I Clamp Mode: In current clamp mode, active commands are the current hold and any external command input signals, summed. Clamp stability is enhanced with the selection of three clamp speeds. Compensation Controls • Voltage Offsets (including junction potentials): are automatically compensated with the auto zero or manually with the junction zero. • Capacity Compensation: Paired controls; fast (0-5 µsec), medium (0-2 msec) and slow (0-20 msec) compensate the current transient caused by a step command signal. Each pair has a separate control for amplitude and time constant. • Series Resistance: Signal errors contributed by the electrode (access) resistance in whole cell recording are subtracted from the output with the series R comp control. The compensated resistance (0-100 M?) is read from a ten turn dial. • Leak Subtract: Used to compensate leakage current due to the voltage drop across the seal (shunt) resistance. Outputs/Signal Conditioning The Im signal is bandwidth limited by a 4-pole Bessel filter with six frequency cut-offs and can be bypassed to obtain the full 10 kHz bandwidth. Gain is selected with a 7 position switch and scaled to the headstage resistor. Additional outputs are Vm x 10 (membrane voltage at x10 gain) active in current clamp mode and ?Vc x 10, the sum of all commands at x10 gain. Rear panel outputs include; gain telegraph, a dc signal which communicates to a data acquisition system the Im output gain level and the headstage in use, and sync output, a signal to synchronize an oscilloscope or computer with one of the internal test signals. Voltammetry with PC-501A/V Simple modifications to the PC-501A make it suitable for voltammetric measurements. They include increasing the holding voltage potential to ±1 volt and the external voltage signal level to ±2 volts maximum. Internal switches can be installed to allow switching between normal [patch] and voltammetry operation. Contact our technical support department for details.
|