Welcome to Harvard Apparatus Limited! Login / Register
Search

Search for these keywords
Home Catalogs Online Technical Resources My Account
Advanced Search   
Products by Category

Featured Products
Warner Cell Electrophysiology & Cell Biology Research
Hugo Sachs Elektronic Isolated Organ and Tissue Systems
BTX Electroporation and Electrofusion Products
Panlab Behavior Research Products
Hoefer Electrophoresis Products
Coulbourn Instruments
Clark Glass Products
Navicyte Ussing/Diffusion Chambers
CMA
Harvard Apparatus
 

Home Microincubation / Microinjectors Microinjection Systems Picoliter Injector Microinjection Systems


Larger Views

 

Picoliter Injector Microinjection Systems

The PLI-90 Pico-Injector, like the reliable PLI-100 Pico-Injector, controls the precise and reporducible regulation of injection pressure and time. It is for applications that do not require a vacuum for filling pipettes barrels or if using a holding pipette for holding cells is not essential to your application.
Search for Product in current catalog
Item Listing Full Description Specifications Journal Articles Manuals
Item# Description
650004 PLI-90 BASIC Pico-Injector with Injection, Balance and Clear Pressures; Includes Input Hose (PLI-IHN) and Output Hose (PLI-OHN), Handle, Power Cord and Inustruction Manual. Applications: Basic setups that do not need suction.
650005 PLI-90 PLUS Pico-Injector Basic Model and Acces-sories (Shown Above), Plus One Each PLI-FS Foot Switch, PLI-PH1 Pipette Holder and PLI-IHA Input Hose Adapter

For local pricing, contact your nearest distributor.



Full Description Back to Top

• 3 pressures — inject, balance, and clearing
• Eliminates backflow into pipette after injection
• Reproducibly delivers femtoliters to microliters
• Easy to use
• Economical
• Precise

The PLI-90 Pico-Injector reliably delivers a wide range of volumes through micropipettes by applying a regulated pressure for a digitally set period of time. Compressed gas allows the user to deliver desired volumes from femtoliters to microliters while simultaneously holding a cell. Whether you need to do large injections into capillaries or very small injections into mammalian nuclei, the PLI-90 is well suited for your experiment.

Easy to Use
Inject with the touch of a button or a tap of the foot switch — it’s as easy as that!

Reproducible
Pressure to the pipette is controlled precisely through a multi-turn regulator, and is reported digitally for easy repeat. Injection time is digitally controlled in 10 msec steps between 0.01 to 0.99 seconds (and in 1 second steps between 1 to 99 seconds). Pipette tip diameter, and hence delivered volume, are easy determinations once the timing and pressure are known.

Versatile
Deliver volumes from femtoliters to microliters with the same instrument, resulting in a wide range of applications.

Pressure Capabilities
The PLI-90 features two negative and three positive pressure pneumatic capabilities.

The negative, or vacuum functions allow the user to:
1. Fill micropipettes from their tips, reducing wastage of valuable injectables.
2. Provide a means to secure and manipulate a cell using a holding pipette.

The positive pressures allow the user to:
1. Eject precise amounts of fluids.

Selection Guidelines
The PLI-90 is available in two packages: Basic and Plus. The basic unit is supplied with an input and output hose, handle, power cord and instruction manual. The plus unit is supplied with all of the same parts as the basic unit but also includes a foot switch, pipette holder and input hose adapter.


Specifications Back to Top

Specifications650004650005
CertificationsCECE
Input Gas Pressure English70 to 105 p.s.i.70 to 105 p.s.i.
Clearing Pressure EnglishInput gas pressure, unregulatedInput gas pressure, unregulated
Injection Pressure English0.2 to 60 p.s.i., regulated, multi-turn control0.2 to 60 p.s.i., regulated, multi-turn control
Balance Pressure English0.1 to 3.5 p.s.i., regulated, multi-turn control, other ranges available upon request0.1 to 3.5 p.s.i., regulated, multi-turn control, other ranges available upon request
Input Gas Pressure Metric480 to 720 kPa480 to 720 kPa
Injection Pressure Metric413 kPa, regulated, multi-turn control413 kPa, regulated, multi-turn control
Balance Pressure Metric68.9 kPa, regulated, multi-turn control, other ranges available upon request68.9 kPa, regulated, multi-turn control, other ranges available upon request
Power Consumption220 W220 W
Injection Timer0.01 to 0.99 sec in 10 msec steps; 1 to 99 sec in 1 sec steps0.01 to 0.99 sec in 10 msec steps; 1 to 99 sec in 1 sec steps
Injection Count DisplayDigital, three and a half digitsDigital, three and a half digits
Duration ModeInternally timed or externally triggeredInternally timed or externally triggered
Time TriggerFoot or panel switchFoot or panel switch
Pressure ReadoutInject, balance, clear, output portInject, balance, clear, output port
Line Voltage100/110/220/240 VAC100/110/220/240 VAC
Foot SwitchesOptional inject and gatingOptional inject and gating
Accessories SuppliedInput hose, output hose and power cordInput hose, output hose and power cord
Height Metric11 cm11 cm
Height English5 in5 in
Width Metric38 cm38 cm
Width English15 in15 in
Depth Metric25.5 cm25.5 cm
Depth English10 in10 in
Weight Metric6.8 kg6.8 kg
Weight English15 lb15 lb

Back to Top



Journal Articles Back to Top

Displaying 1 to 10 of 30results for Picoliter Injector Microinjection Systems   Page 1  2  3 

Score

Document

Description

100% Login to view The role of bone morphogenetic proteins.pdf
[350 KB]
The role of bone morphogenetic proteins in the differentiation of the ventral Optic cup
90% Login to view Ca21-Independent Protein Kinase C Apl II Mediates.pdf
[372 KB]
Ca2+ Independent Protein Kinase C Apl II Mediates the Serotonin-Induced Facilitation at Depressed Aplysia Sensorimotor Synapses
75% Login to view Zebrafish mitotic kinesin-like protein 1 functions in embryonic cytokinesis.pdf
[1.1 MB]
Zebrafish mitotic kinesin-like protein 1 (Mklp1) functions in embryonic cytokinesis
45% Login to view PI02.pdf
[431 KB]
Pico-Injector use in Inhibition of the Inositol Trisphosphate Receptor of Mouse Eggs and A7r5 Cells
38% Login to view Inhibition of the Inositol Trisphosphate Receptor of Mouse Eggs.pdf
[440 KB]
Pico-Injector use in Inhibition of the Inositol Trisphosphate Receptor of Mouse Eggs and A7r5 Cells by KN-93 via a Mechanism Unrelated to Ca2 /Calmodulin-dependent Protein Kinase II Antagonism
34% Login to view PI03.pdf
[1.1 MB]
Zebrafish mitotic kinesin-like protein 1 (Mklp1) functions in embryonic cytokinesis
28% Login to view Permeability and gating properties of human connexins 26 and 30 expressed in HeLa cells.pdf
[425 KB]
Pico-Injector used in finding Permeability and gating properties of human connexins 26 and 30 expressed in HeLa cells
27% Login to view PP69 PHD 2000 Syringe Pump.pdf
[598 KB]
Passive mixing in a three-dimensional serpentine microchannel - Microelectromechanical Systems, Journal of
27% Login to view BOR Papers in Press. Published on December 3, 2003.pdf
[289 KB]
Patterns of Intracellular Calcium Oscillations in Horse Oocytes Fertilized by Intracytoplasmic Sperm Injection
23% Login to view The Red Tide Toxin, Brevetoxin, Induces Embryo Toxicity and Developmental Abnormalities.pdf
[124 KB]
PL-100, The Red Tide Toxin, Brevetoxin, Induces Embryo Toxicity and Developmental Abnormalities
   

Back to Top



Manuals Back to Top

Displaying 1 to 1 of 1result for Picoliter Injector Microinjection Systems  

Score

Document

Description

100% Login to view PicoInjector PLI90.pdf
[110 KB]
Model PLI-90 Pico Injector Manual
   

Back to Top

NEW
Breakthrough Products for Regenerative Medicine
2011 Regenerative Medicine Brochure
100's of Innovative products developed with leading scientists & surgeons!
  • Injection & Perfusion
  • Bioreactors
  • Biosensing
  • Total Solutions
  • Total Support


Announcing the new
PHD ULTRA™ Syringe Pumps

Click here for more information about PHD ULTRA™ Syringe Pumps and to download a brochure.

  • Patent pending mechanical design provides highest accuracy/precision & smoothest flow
  • Easy operation with advanced touch screen
  • Advanced EZ PRO™ software for PC functions without a PC.


Sign-up for a FREE Full Line Bioresearch Catalog
CLICK HERE!

  • Over 11,000 specialty products to enhance your bioresearch
  • Enhanced solutions for small animal research
  • 100's of pages of specialized information on instrumentation, applications, uses of products

 

Products on this website are for Research Use Only. Not for use in humans unless
proper investigational device regulations have been followed.


Privacy Policy   |   Terms and Conditions   
Copyright© Harvard Apparatus Ltd. - All rights reserved.
(44) 1732-864001
Website-related comments or concerns can be emailed to our webmaster.

Anesthesia Equipment Animal Handling Products Behavior Research Products Biological Measurement Products Cardiovascular Products Cell Biology Products Microincubation / Microinjectors CPK® Atomic Models Delivery & Sampling Products Dialysis / Sample Prep / SPE Electroporation / Transfection Electrophysiology Products General Laboratory Products Homeothermic/Temperature Control Isolated Organ & Isolated Tissue Molecular Biology Products Neuroscience Products Non-Invasive Blood Pressure Physiology Products Respiratory Products Stereotaxic Instruments Surgical Equipment Surgical Instruments Syringe Pumps/Peristaltic Pumps Tubing & Connectors Ventilators