Home Respiratory Products Pulse Oximeter V3304 Pulse Oximeters


Larger Views

 

V3304 Pulse Oximeters

Using refined noise-reduction hardware (digital processing) and a unique patented software algorithm Serial Auto Correlation (SAC™), the V3304 is able to look at pulse oximetry data in a whole new way. This innovative oximeter technology analyzes a digital signal at a rate of 120 times per second and compares it to previous pulse data. These pulses are constantly stored and updated, and used as dynamic templates to determine the validity or invalidity for newly encountered pulsatile signals. The V3304 offers the same advanced features as the V3402, see page F46, but in a table top package with extended data storage capabilities. Three user-selectable averaging modes are available, visual and audible indicators for SpO2 and pulse rate, an 8 segment LED bar indicator for pulse strength as well as high and low limit adjustable alarms for SpO2 and pulse rate. Low priority alarms warn the user of system setup malfunctions such as a disconnected probe. The audible indicators and alarms vary in rate and pitch to indicate changes in pulse rate and SpO2 level, respectively.
Search for Product in current catalog
Item Listing Full Description Specifications Manuals
Item# Description
723174 V3304 Digital Table Top Pulse Oximeter, 110 VAC, 60 Hz
723264 V3304 Digital Table Top Pulse Oximeter, 220 VAC, 50 Hz

For local pricing, contact your nearest distributor.



Full Description Back to Top

• Internal rechargeable battery
• Easy-to-read LED display with adjustable brightness
• Variety of reusable sensors designed for animal applications
• Quantitative pulse strength bar
• Advanced Digital SAC™ oximetry for demanding research environments

Using refined noise-reduction hardware (digital processing) and a unique patented software algorithm Serial Auto Correlation (SAC™), the V3304 is able to look at pulse oximetry data in a whole new way. This innovative oximeter technology analyzes a digital signal at a rate of 120 times per second and compares it to previous pulse data. These pulses are constantly stored and updated, and used as dynamic templates to determine the validity or invalidity for newly encountered pulsatile signals. The V3304 offers the same advanced features as the V3402, see page F46, but in a table top package with extended data storage capabilities. Three user-selectable averaging modes are available, visual and audible indicators for SpO2 and pulse rate, an 8 segment LED bar indicator for pulse strength as well as high and low limit adjustable alarms for SpO2 and pulse rate. Low priority alarms warn the user of system setup malfunctions such as a disconnected probe. The audible indicators and alarms vary in rate and pitch to indicate changes in pulse rate and SpO2 level, respectively.
Animal IDs from 0-99 are used by the V3304 to delineate multiple animal data measurements. An optional serial printer, BS4 72-3173, is available which can be used to output animal data in continuous datal log mode (every 5 seconds) or trend mode (every 4-30 seconds). Trend data continues to be stored even when data is being printed using the data log mode. The V3304 can store up to 90 hours of trend data for up to 99 individual animals. The trend storage interval is user selectable from 4-30 seconds. Decreasing the trend storage interval decreases the maximum length of time data can be stored in memory. Output of data to a computer requires the use of BS4 72-3166 printer interface cable and BS4 72-3155 PC adapter cable. The V3304 Pulse Oximeter comes with an instruction manual, AC adapter/charger, BS4 72-3157 5 foot oximeter extension cable, BS4 72-3254 small reflectance probe and the BS4 72-3256 small to medium Y-Clip probe. The unit is powered by an internal rechargeable lead acid battery. Other pulse oximeter probes and accessories are available, see to the right.


Specifications Back to Top

Specifications723174723264
Height Metric216 mm216 mm
Height English3.4 in3.4 in
Width Metric82 mm82 mm
Width English8.5 in8.5 in
Depth Metric140 mm140 mm
Depth English5.5 in5.5 in
Weight Metric850 g850 g
Weight English30 oz30 oz
SpO2: Range0 to 100%0 to 100%
SpO2: Accuracy±2% at 70 to 100% ±3% at 50 to 69%±2% at 70 to 100% ±3% at 50 to 69%
SpO2: Alarm RangeHigh: 50 to 100% and Off (1% steps) Low: 50 to 99% and Off (1% steps)High: 50 to 100% and Off (1% steps) Low: 50 to 99% and Off (1% steps)
SpO2: Averaging4, 6, or 16 pulse beat average4, 6, or 16 pulse beat average
SpO2 & Plus Rate3-digit LED display, 10 mm (0.43 in) high3-digit LED display, 10 mm (0.43 in) high
Pulse Rate: Range20 to 350 bpm20 to 350 bpm
Pulse Rate: Accuracy±1 beat or 2% whichever is greater±1 beat or 2% whichever is greater
Pulse Rate: Alarm RangeHigh: 5 to 350 BPM and Off (5 BPM steps) Low: 5 to 350 BPM and Off (5 BPM steps)High: 5 to 350 BPM and Off (5 BPM steps) Low: 5 to 350 BPM and Off (5 BPM steps)
Pulse Rate: Averaging8 or 16 sec average8 or 16 sec average
Battery RequirementsStandard Lead-Acid battery: Internal rechargeable; not user replaceable. Fully charges in about 6 hrs. Approximately 4.5 hrs continuous useStandard Lead-Acid battery: Internal rechargeable; not user replaceable. Fully charges in about 6 hrs. Approximately 4.5 hrs continuous use
CertificationsDesigned to meet IEC-601-1, CSA 125, UL 544, and CE (EMC)Designed to meet IEC-601-1, CSA 125, UL 544, and CE (EMC)
Power Requirements110 VAC, 60 Hz220 VAC, 50 Hz
Printer OutputSpO2 and pulse rate can be printed every five (5) sec (data log). Data saved every four (4) to thirty (30) sec can be printed (trend) Analog Output (optional) Digital Output (optional)SpO2 and pulse rate can be printed every five (5) sec (data log). Data saved every four (4) to thirty (30) sec can be printed (trend) Analog Output (optional) Digital Output (optional)
AC Charger Voltage Requirements: Wall Mount105 to 125 VAC, 60 Hz 100 V – Hz (Optional)105 to 125 VAC, 60 Hz 100 V – Hz (Optional)
AC Charger Voltage Requirements: Table Top230 VAC; 50/60 Hz230 VAC; 50/60 Hz

Back to Top



Manuals Back to Top

Displaying 1 to 2 of 2results for V3304 Pulse Oximeters  

Score

Document

Description

100% Login to view Pump11 VPF.pdf
[133 KB]
Model 11 Syringe Pump Series Manual
80% Login to view Pump11 VPF 2002.pdf
[187 KB]
Model 11 VPF Syringe Pump Manual
   

Back to Top

Breakthrough Products for Regenerative Medicine
2011 Regenerative Medicine Brochure
100's of Innovative products developed with leading scientists & surgeons!
  • Injection & Perfusion
  • Bioreactors
  • Biosensing
  • Total Solutions
  • Total Support


Announcing the new
PHD ULTRA™ Syringe Pumps

Click here for more information about PHD ULTRA™ Syringe Pumps and to download a brochure.

  • Patent pending mechanical design provides highest accuracy/precision & smoothest flow
  • Easy operation with advanced touch screen
  • Advanced EZ PRO™ software for PC functions without a PC.


Sign-up for a FREE Full Line Bioresearch Catalog
CLICK HERE!

  • Over 11,000 specialty products to enhance your bioresearch
  • Enhanced solutions for small animal research
  • 100's of pages of specialized information on instrumentation, applications, uses of products

 

Products on this website are for Research Use Only. Not for use in humans unless
proper investigational device regulations have been followed.


Privacy Policy   |   Terms and Conditions   
Copyright© Harvard Apparatus Ltd. - All rights reserved.
(44) 1732-864001
Website-related comments or concerns can be emailed to our webmaster.

Anesthesia Equipment Animal Handling Products Behavior Research Products Biological Measurement Products Cardiovascular Products Cell Biology Products Microincubation / Microinjectors CPK® Atomic Models Delivery & Sampling Products Dialysis / Sample Prep / SPE Electroporation / Transfection Electrophysiology Products General Laboratory Products Homeothermic/Temperature Control Isolated Organ & Isolated Tissue Molecular Biology Products Neuroscience Products Non-Invasive Blood Pressure Physiology Products Respiratory Products Stereotaxic Instruments Surgical Equipment Surgical Instruments Syringe Pumps/Peristaltic Pumps Tubing & Connectors Ventilators