Harvard Apparatus
 

Home Syringe Pumps/Peristaltic Pumps Syringe Pumps Low EF Noise Pump


Larger Views

 

Low EF Noise Pump

The PHYSIO 22 Pump delivers high accuracy, pulseless flow with no electrical noise to interfere with the sensor signal while performing physiological analyses. This specialty pump is based on our legendary Syringe Pump 22, but with a special toroidal transformer designed for minimum EF. This new transformer cuts electrical noise so that it is almost non existent.
Search for Product in current catalog
Item Listing Full Description Specifications Journal Articles Manuals
Item# Description
702222 PHYSIO 22 Syringe Pump

For local pricing, contact your nearest distributor.



Full Description Back to Top

• Low EF noise
• Pulse less flow
• High accuracy Applications
• Patch Clamping
• Oocyte applications
• Cellular injections

The PHYSIO 22 Pump delivers high accuracy, pulseless flow with no electrical noise to interfere with the sensor signal while performing physiological analyses. This specialty pump is based on our legendary Syringe Pump 22, but with a special toroidal transformer designed for minimum EF. This new transformer cuts electrical noise so that it is almost non existent.

The electrical noise difference between our standard pump 22 and this new model is quite dramatic. Standard pumps generate a magnetic field which will induce a current into the conductive media coming out of the syringe. This will create noise in the biological reading/recordings. With the new PHSIO 22, even the most sensitive sensors will not show a noise spike. With the new toroidal transformer the noise disappears completely.

These types of applications are particularly sensitive to electrical noise and therefore would benefit tremendously by using our new PHYSIO 22 Syringe Pump.

Some basic specifications are listed on this page. For complete details and specifications on this pump please see the Pump 22 Syringe Pump. This pump is currently available as infusion only with standard 2-syringe rack. An infuse/withdraw model is available by special order. Please call for details.

A spurious electromagnetic signal was recently found within the design of the Physio 22 which allowed the introduction of a small 50/60 Hz signal into a shielded environment. In particular, a small transformer within the Physio 22 generated an electromagnetic field which was sensed by an adjacent perfusion line. The problem was corrected by replacing the offending transformer with one incorporating toroidal architecture. This change in design successfully contains the stray electromagnetic field and renders the device electrically silent.


Specifications Back to Top

Specifications702222
TypeMicroprocessor 2-syringe, infusion only
Pump FunctionInfusion Only
Flow Rate Minimum0.002 µl/hr
Flow Rate Maximum55.1 ml/min
# of Syringes2
Syringe Rack TypeStandard Rack
Syringe Size Minimum0.5 µl
Syringe Size Maximum140 ml
Accuracy0.35 %
Reproducibility0.5 %
Voltage Range95 to 130 VAC, 60 Hz; 220 to 260 VAC, 50 Hz, selectable
Height Metric28 cm
Height English11 in
Width Metric22.2 cm
Width English8.75 in
Depth Metric14 cm
Depth English5.5 in
Net Weight Metric4.5 kg
Net Weight English10 lbs

Back to Top



Journal Articles Back to Top

Displaying 1 to 10 of 35results for Low EF Noise Pump   Page 1  2  3  4 

Score

Document

Description

100% Login to view PP12 Pump 11 Syringe.pdf
[179 KB]
Syringe Pump use in Studies of potential-dependent metallothionein adsorptions using a low-volume electrochemical quartz crystal microbalance flow cell
76% Login to view PP13 Pump 22 Syringe.pdf
[646 KB]
Syringe Pump use in finding A set-point model with oscillatory behavior predicts the time course of 8-OH-DPAT-induced hypothermia
52% Login to view PP185.pdf
[191 KB]
Single-Molecule Tracing on a Fluidic Microchip for Quantitative Detection of Low-Abundance Nucleic Acids
45% Login to view PP114 pump microchannel.pdf
[74 KB]
Syringe Infusion Pump use in finding Microchannel Devices for Efficient Contacting of Liquids in Solvent Extraction
44% Login to view PP04 pump ms.pdf
[53 KB]
Analysis of Jojoba Oil with syringe pump 'apparatus 22'
41% Login to view VT24 Pump Ventilator.pdf
[90 KB]
Intramucosal-arterial Pco2 gap fails to reflect intestinal dysoxia in hypoxic hypoxia
40% Login to view PP96 22 pump eq.pdf
[944 KB]
Syringe Pump use in finding Intrarenal Dopamine Production and Distrobution in the Rat
40% Login to view PP08 Mechanical Pump 901A.pdf
[188 KB]
Mechanical Pump use in finding NO supports right ventricular flow dominance
40% Login to view PP44 Syringe MS Pump 11.pdf
[519 KB]
Comprehensive Two-Dimensional High-Performance Liquid Chromatography for the Isolation of Overexpressed Proteins and Proteome Mapping
39% Login to view PP57 Respiratory Pump 57.pdf
[209 KB]
Respirator pump use in finding Quantification of Cerebral Perfusion With "Real Time" Contrast-Enhanced Ultrasound
   

Back to Top



Manuals Back to Top

Displaying 1 to 3 of 3results for Low EF Noise Pump  

Score

Document

Description

100% Login to view Pump Selection Guide.pdf
[263 KB]
DC1_A_Pumps.qxd
74% Login to view 11 Elite Syringe Pump User Manual.pdf
[3.2 MB]
Pump 11 Elite User Manual
67% Login to view Nanoleader Pump Series NLS110P Pressure Pump Manual.pdf
[2.2 MB]
705000 NLS110P Pump Manual
   

Back to Top

Breakthrough Products for Regenerative Medicine
2011 Regenerative Medicine Brochure
100's of Innovative products developed with leading scientists & surgeons!
  • Injection & Perfusion
  • Bioreactors
  • Biosensing
  • Total Solutions
  • Total Support


Announcing the new
PHD ULTRA™ Syringe Pumps

Click here for more information about PHD ULTRA™ Syringe Pumps and to download a brochure.

  • Patent pending mechanical design provides highest accuracy/precision & smoothest flow
  • Easy operation with advanced touch screen
  • Advanced EZ PRO™ software for PC functions without a PC.


Sign-up for a FREE Full Line Bioresearch Catalog
CLICK HERE!

  • Over 11,000 specialty products to enhance your bioresearch
  • Enhanced solutions for small animal research
  • 100's of pages of specialized information on instrumentation, applications, uses of products

 

Products on this website are for Research Use Only. Not for use in humans unless
proper investigational device regulations have been followed.


Privacy Policy   |   Terms and Conditions   
Copyright© Harvard Apparatus Ltd. - All rights reserved.
(44) 1223-423723
Website-related comments or concerns can be emailed to our webmaster.

Anesthesia Equipment Animal Handling Products Behavior Research Products Biological Measurement Products Cardiovascular Products Cell Biology Products Microincubation / Microinjectors CPK® Atomic Models Delivery & Sampling Products Dialysis / Sample Prep / SPE Electroporation / Transfection Electrophysiology Products General Laboratory Products Homeothermic/Temperature Control Isolated Organ & Isolated Tissue Molecular Biology Products Neuroscience Products Non-Invasive Blood Pressure Physiology Products Respiratory Products Stereotaxic Instruments Surgical Equipment Surgical Instruments Syringe Pumps/Peristaltic Pumps Tubing & Connectors Ventilators