Welcome to Harvard Apparatus Limited! Login / Register
Search

Search for these keywords
Home Catalogs Online Technical Resources My Account
Advanced Search   
Products by Category

Featured Products
HART
Warner Cell Electrophysiology & Cell Biology Research
Hugo Sachs Elektronic Isolated Organ and Tissue Systems
BTX Electroporation and Electrofusion Products
Panlab Behavior Research Products
Hoefer Electrophoresis Products
Coulbourn Instruments
Clark Glass Products
Navicyte Ussing/Diffusion Chambers
CMA
Harvard Apparatus
 

Home Cardiovascular Products Pressure Transducers Venous Pressure Transducers


Larger Views

 

Venous Pressure Transducers

The P75 has a removable Macrolon® dome with a pressure connection and a vent connection at the side, so that it can be filled free of air bubbles. The dome connections have a male Luer taper so that suitable stopcocks can be attached. The transducer has a metal housing. The actual pressure sensor inside is made from ceramic and therefore has excellent resistance to different media. The transducer's rugged construction can withstand pressure overloads up to 4000 mmHg without damage. It works together with any DC bridge amplifier (e.g., PLUGSYS TAM–A).
Search for Product in current catalog
Item Listing Full Description Specifications Journal Articles Manuals
Item# Description
730020 Blood Pressure Transducer P75 for PLUGSYS Module
730021 Blood Pressure Transducer P75 for Harvard Apparatus Transducer Interface
730022 Blood Pressure Transducer P75 for Grass Amplifiers
730023 Blood Pressure Transducer P75 for Gould 6600 Series
730025 Replacement Dome for Venous Blood Pressure
733738 Blood Pressure Transducer P75 for ADInstruments Bridge Amp

For local pricing, contact your nearest distributor.



Full Description Back to Top

• For low liquid and gas pressure measurement ±75 mmHg
• Increased sensitivity and baseline stability
• Applications include:
— Venous blood pressure
— Esophageal pressure with fluid filled catheter
— Perfusion pressure on isolated lung and liver
— Perfusion pressure on perfused hollow organs like the esophagus
• Robust construction, easy to fill bubble free

The P75 has a removable Macrolon® dome with a pressure connection and a vent connection at the side, so that it can be filled free of air bubbles. The dome connections have a male Luer taper so that suitable stopcocks can be attached. The transducer has a metal housing. The actual pressure sensor inside is made from ceramic and therefore has excellent resistance to different media. The transducer's rugged construction can withstand pressure overloads up to 4000 mmHg without damage. It works together with any DC bridge amplifier (e.g., PLUGSYS TAM–A).


Specifications Back to Top

Specifications730020730021730022730023730025733738
CertificationsCECECECE CE
Linearity±0.15 mmHg±0.15 mmHg±0.15 mmHg±0.15 mmHg ±0.15 mmHg
Pressure Range±75 mmHg±75 mmHg±75 mmHg±75 mmHg ±75 mmHg
Overload Pressure?760 (= vacuum) to 4,000 mmHg?760 (= vacuum) to 4,000 mmHg?760 (= vacuum) to 4,000 mmHg?760 (= vacuum) to 4,000 mmHg ?760 (= vacuum) to 4,000 mmHg
Transducer Height Metric40 mm40 mm40 mm40 mm 40 mm
Transducer Width Metric40 mm40 mm40 mm40 mm 40 mm
Transducer Metric Depth35 mm35 mm35 mm35 mm 35 mm
Transducer Height English1.57 in1.57 in1.57 in1.57 in 1.57 in
Transducer Width English1.57 in1.57 in1.57 in1.57 in 1.57 in
Transducer Depth English1.38 in1.38 in1.38 in1.38 in 1.38 in
Weight Metric0.35 kg0.35 kg0.35 kg0.35 kg 0.35 kg
Weight English0.8 lb0.8 lb0.8 lb0.8 lb 0.8 lb
Volume Displacement0.06 mm3 /10 mmHg0.06 mm3 /10 mmHg0.06 mm3 /10 mmHg0.06 mm3 /10 mmHg 0.06 mm3 /10 mmHg
Long ndash Term Drift±0.04 mmHg±0.04 mmHg±0.04 mmHg±0.04 mmHg ±0.04 mmHg
Measurement MediaAll gases and liquids which do not attack Macrolon®All gases and liquids which do not attack Macrolon®All gases and liquids which do not attack Macrolon®All gases and liquids which do not attack Macrolon® All gases and liquids which do not attack Macrolon?
Temperature Range Metric0 to 50 °C0 to 50 °C0 to 50 °C0 to 50 °C 0 to 50 °C
Zero Drift±0.04 mmHg/10°C (0° to 50°C)±0.04 mmHg/10°C (0° to 50°C)±0.04 mmHg/10°C (0° to 50°C)±0.04 mmHg/10°C (0° to 50°C) ±0.04 mmHg/10°C (0° to 50°C)
Range Drift±0.04 mV/10°C (±0.04 mmHg/10°C) (0° to 50°C)±0.04 mV/10°C (±0.04 mmHg/10°C) (0° to 50°C)±0.04 mV/10°C (±0.04 mmHg/10°C) (0° to 50°C)±0.04 mV/10°C (±0.04 mmHg/10°C) (0° to 50°C) ±0.04 mV/10°C (±0.04 mmHg/10°C) (0° to 50°C)
Supply Voltage5 V (4.5 to 5.5 V) DC only5 V (4.5 to 5.5 V) DC only5 V (4.5 to 5.5 V) DC only5 V (4.5 to 5.5 V) DC only 5 V (4.5 to 5.5 V) DC only
Current Loading15 mA max.15 mA max.15 mA max.15 mA max. 15 mA max.
Sensitivity1 mV/mmHg, nominal1 mV/mmHg, nominal1 mV/mmHg, nominal1 mV/mmHg, nominal 1 mV/mmHg, nominal
Output Resistance300 Ω, nominal300 Ω, nominal300 Ω, nominal300 Ω, nominal 300 Ω, nominal
Frequency Range0 to 100 Hz0 to 100 Hz0 to 100 Hz0 to 100 Hz 0 to 100 Hz
Connection Cable Length Metric14.5 m14.5 m14.5 m14.5 m 14.5 m
Connection Cable Length English4.9 ft4.9 ft4.9 ft4.9 ft 4.9 ft
Suitable AmplifiersAny bridge amp providing 5V DC excitation voltageAny bridge amp providing 5V DC excitation voltageAny bridge amp providing 5V DC excitation voltageAny bridge amp providing 5V DC excitation voltage Any bridge amp providing 5V DC excitation voltage
Pressure ConnectionsLuer taper, maleLuer taper, maleLuer taper, maleLuer taper, male Luer taper, male
Mounting Rod OD Metric8 mm8 mm8 mm8 mm 8 mm
Mounting Rod Length Metric70 mm70 mm70 mm70 mm 70 mm
Mounting Rod OD English0.31 in0.31 in0.31 in0.31 in 0.31 in
Mounting Rod Length English2.76 in2.76 in2.76 in2.76 in 2.76 in

Back to Top



Journal Articles Back to Top

Displaying 1 to 10 of 22results for Venous Pressure Transducers   Page 1  2  3 

Score

Document

Description

100% Login to view HS08 pressure transducer.pdf
[46 KB]
Pressure Transducer use in finding blood pressure and heart rate spectral changes
43% Login to view BP05.pdf
[2.7 MB]
Not Available
30% Login to view HS16 In Vivo Pharmacology of the PDE4 Inhibitor Roflumilast.pdf
[325 KB]
Transducer use In Vivo Efficacy in Airway Disease Models of Rofulmilast
28% Login to view HS07EL Oxytocin actions in guinea-pig uterine artery.pdf
[158 KB]
Displacement Transducer use in Characterization of oxycotin actions in guinea-pig isolated uterin artery: The effect of pregnancy
25% Login to view HS02IS Evaluation of Skeletonized LITA.pdf
[228 KB]
Isolated Organ Set use in Intraoperative and Laboratory Evaluation of Skeletonized Versus Pedicled Internal Thoracic Artery
25% Login to view HS19 Soluble Guanylyl Cyclase in Aging and Hypertension.pdf
[238 KB]
hy010000043p
25% Login to view HS01 Opioids and Coronary Vascular Tone.pdf
[138 KB]
Force Transducer influence of opioids on the vascular tone of isolated porcine coronary artery segments
25% Login to view HS18ST Inotropic Effects of Pyruvate.pdf
[96 KB]
Influence of Pyruvate on Contractile Performance
23% Login to view PP94 Aquaporin Deletion in Mice Reduces Intraocular Pressure and Aqueous Fluid Production.pdf
[722 KB]
Aquaporin Deletion in Mice Reduces Intraocular Pressure and Aqueous Fluid Production
22% Login to view VT06 Ventilator use in finding load as an acute determinant of end-diastolic pressure-volume relation.pdf
[200 KB]
h4Ventilator use in finding load as an acute determinant of end-diastolic pressure-volume relation010100051p
   

Back to Top



Manuals Back to Top

Displaying 1 to 4 of 4results for Venous Pressure Transducers  

Score

Document

Description

100% Login to view Nanoleader Pump Series NLS110P Pressure Pump Manual.pdf
[2.2 MB]
705000 NLS110P Pump Manual
98% Login to view Model708 557081.pdf
[43 KB]
Harvard 708 Pressure Controlled Ventilator Manual
89% Login to view 603002 603003.pdf
[77 KB]
Research Grade Blood Pressure Transducer Manual
81% Login to view 724488 724489.pdf
[124 KB]
Research Grade Blood Pressure Transducer Manual
   

Back to Top

FREE 15 Day Trial
SMART 3.0 Advanced Video Tracking System
SMART 3.0 Advanced Video Tracking System

Download Free Trial


User friendly interface with power & flexibility to increase the productivity of your research!
  • Spontaneous tracking
  • Advanced calculations
  • Superior zone editing
  • 2D and 3D mapping
  • Built-in DVR system


Announcing the new
PHD ULTRA™ Syringe Pumps

Click here for more information about PHD ULTRA™ Syringe Pumps and to download a brochure.

  • Patent pending mechanical design provides highest accuracy/precision & smoothest flow
  • Easy operation with advanced touch screen
  • Advanced EZ PRO™ software for PC functions without a PC.


Sign-up for a FREE Full Line Bioresearch Catalog
CLICK HERE!

  • Over 11,000 specialty products to enhance your bioresearch
  • Enhanced solutions for small animal research
  • 100's of pages of specialized information on instrumentation, applications, uses of products

 

Products on this website are for Research Use Only. Not for use in humans unless
proper investigational device regulations have been followed.


Privacy Policy   |   Terms and Conditions   
Copyright© Harvard Apparatus Ltd. - All rights reserved.
(44) 1732-864001
Website-related comments or concerns can be emailed to our webmaster.

Anesthesia Equipment Animal Handling Products Behavior Research Products Biological Measurement Products Cardiovascular Products Cell Biology Products Microincubation / Microinjectors CPK® Atomic Models Delivery & Sampling Products Dialysis / Sample Prep / SPE Electroporation / Transfection Electrophysiology Products General Laboratory Products Homeothermic/Temperature Control Isolated Organ & Isolated Tissue Molecular Biology Products Neuroscience Products Non-Invasive Blood Pressure Physiology Products Respiratory Products Stereotaxic Instruments Surgical Equipment Surgical Instruments Syringe Pumps/Peristaltic Pumps Tubing & Connectors Ventilators