Welcome to Harvard Apparatus Limited! Login / Register
Search

Search for these keywords
Home Catalogs Online Technical Resources My Account
Advanced Search   
Products by Category

Featured Products
HART
Warner Cell Electrophysiology & Cell Biology Research
Hugo Sachs Elektronic Isolated Organ and Tissue Systems
BTX Electroporation and Electrofusion Products
Panlab Behavior Research Products
Hoefer Electrophoresis Products
Coulbourn Instruments
Clark Glass Products
Navicyte Ussing/Diffusion Chambers
CMA
Harvard Apparatus
 

Home Cardiovascular Products Pressure Transducers APT300 Pressure Transducers


Larger Views

 

APT300 Pressure Transducers

This APT300 Transducer is an inexpensive pressure transducer which can be used to measure arterial blood pressures in all species, even on mice with a high heart rate. This transducer is typically used for arterial pressure measurement in vivo, perfusion pressures in isolated perfused organs such as heart or kidney, Isovolumetric Left Ventricular (using a balloon) pressures in isolated hearts from mice up to rabbits or pigs. The APT300 Transducer consists of a contact plate with cable and the exchangeable transducer head, which can easily be replaced. Contact plates with cables for different amplifiers are available.
Search for Product in current catalog
Item Listing Full Description Specifications Journal Articles Manuals
Item# Description
733862 APT300 Pressure Transducer for PLUGSYS Module
733863 APT300 Pressure Transducer for Harvard Apparatus Transducer Interface
733864 APT300 Pressure Transducer for Grass Amplifiers
733865 APT300 Pressure Transducer for Gould 6600 Series
733866 APT300 Pressure Transducer for ADInstruments Bridge Amp

For local pricing, contact your nearest distributor.



Full Description Back to Top

• Inexpensive
• Reliable
• Accurate
• Low volume displacement
• Suitable for virtually all arterial pressure applications
• Easy to fill
• Stopcocks Included
• Simple holder for rod mounting

This APT300 Transducer is an inexpensive pressure transducer which can be used to measure arterial blood pressures in all species, even on mice with a high heart rate. This transducer is typically used for arterial pressure measurement in vivo, perfusion pressures in isolated perfused organs such as heart or kidney, Isovolumetric Left Ventricular (using a balloon) pressures in isolated hearts from mice up to rabbits or pigs. The APT300 Transducer consists of a contact plate with cable and the exchangeable transducer head, which can easily be replaced. Contact plates with cables for different amplifiers are available.


Specifications Back to Top

Specifications733862733863733864733865733866
CertificationsCECECECECE
Pressure Range± 300 mmHg± 300 mmHg± 300 mmHg± 300 mmHg± 300 mmHg
Overload Pressure4,000 mmHg4,000 mmHg4,000 mmHg4,000 mmHg4,000 mmHg
Zero Offset Control<25 mmHg<25 mmHg<25 mmHg<25 mmHg<25 mmHg
Frequency Response>1 kHz>1 kHz>1 kHz>1 kHz>1 kHz
Isolation Against Fluid>5,000 V>5,000 V>5,000 V>5,000 V>5,000 V
Output Impedance356 ± 1% Ω356 ± 1% Ω356 ± 1% Ω356 ± 1% Ω356 ± 1% Ω
Volume Displacement< 0.04 mmˆ3/100 mmHg< 0.04 mmˆ3/100 mmHg< 0.04 mmˆ3/100 mmHg< 0.04 mmˆ3/100 mmHg< 0.04 mmˆ3/100 mmHg
Zero Drift< 0.2 mmHg/°C< 0.2 mmHg/°C< 0.2 mmHg/°C< 0.2 mmHg/°C< 0.2 mmHg/°C
Zero Offset<25 mmHg<25 mmHg<25 mmHg<25 mmHg<25 mmHg
Sensitivity5 µV/V/mmHg5 µV/V/mmHg5 µV/V/mmHg5 µV/V/mmHg5 µV/V/mmHg
Connection Cable Length Metric3 m3 m3 m3 m3 m
Suitable AmplifiersPLUGSYSHarvard ApparatusGrassGould 6600ADInstruments Bridge Amp
Operating Pressure–300 to 300 mmHg–300 to 300 mmHg–300 to 300 mmHg–300 to 300 mmHg–300 to 300 mmHg
Excitation Voltage2 — 15 V DC (or AC up to 5 kHz)2 — 15 V DC (or AC up to 5 kHz)2 — 15 V DC (or AC up to 5 kHz)2 — 15 V DC (or AC up to 5 kHz)2 — 15 V DC (or AC up to 5 kHz)
Temperature Coefficient< 1% /°C< 1% /°C< 1% /°C< 1% /°C< 1% /°C
Operating Temperature Metric15 to 40 °C15 to 40 °C15 to 40 °C15 to 40 °C15 to 40 °C
Storage Temperature Metric–25 to 70 °C–25 to 70 °C–25 to 70 °C–25 to 70 °C–25 to 70 °C

Back to Top



Journal Articles Back to Top

Displaying 1 to 10 of 26results for APT300 Pressure Transducers   Page 1  2  3 

Score

Document

Description

100% Login to view HS08 pressure transducer.pdf
[46 KB]
Pressure Transducer use in finding blood pressure and heart rate spectral changes
61% Login to view HS16 In Vivo Pharmacology of the PDE4 Inhibitor Roflumilast.pdf
[325 KB]
Transducer use In Vivo Efficacy in Airway Disease Models of Rofulmilast
56% Login to view HS07EL Oxytocin actions in guinea-pig uterine artery.pdf
[158 KB]
Displacement Transducer use in Characterization of oxycotin actions in guinea-pig isolated uterin artery: The effect of pregnancy
50% Login to view HS19 Soluble Guanylyl Cyclase in Aging and Hypertension.pdf
[238 KB]
hy010000043p
50% Login to view HS01 Opioids and Coronary Vascular Tone.pdf
[138 KB]
Force Transducer influence of opioids on the vascular tone of isolated porcine coronary artery segments
50% Login to view HS18ST Inotropic Effects of Pyruvate.pdf
[96 KB]
Influence of Pyruvate on Contractile Performance
47% Login to view PP94 Aquaporin Deletion in Mice Reduces Intraocular Pressure and Aqueous Fluid Production.pdf
[722 KB]
Aquaporin Deletion in Mice Reduces Intraocular Pressure and Aqueous Fluid Production
45% Login to view VT06 Ventilator use in finding load as an acute determinant of end-diastolic pressure-volume relation.pdf
[200 KB]
h4Ventilator use in finding load as an acute determinant of end-diastolic pressure-volume relation010100051p
41% Login to view HS12P2 Effects of GYK!-16638 in rabbits.pdf
[236 KB]
PII: S0014-2999(00)00591-4
27% Login to view Rapid Intermittent Movement of Axonal Neurofilaments.PDF
[743 KB]
Pressure Injector use in finding Rapid Intermittent Movement of Axonal Neurofilaments Observed by Fluorescene Photobleaching
   

Back to Top



Manuals Back to Top

Displaying 1 to 4 of 4results for APT300 Pressure Transducers  

Score

Document

Description

100% Login to view Nanoleader Pump Series NLS110P Pressure Pump Manual.pdf
[2.2 MB]
705000 NLS110P Pump Manual
98% Login to view Model708 557081.pdf
[43 KB]
Harvard 708 Pressure Controlled Ventilator Manual
89% Login to view 603002 603003.pdf
[77 KB]
Research Grade Blood Pressure Transducer Manual
81% Login to view 724488 724489.pdf
[124 KB]
Research Grade Blood Pressure Transducer Manual
   

Back to Top

FREE 15 Day Trial
SMART 3.0 Advanced Video Tracking System
SMART 3.0 Advanced Video Tracking System

Download Free Trial


User friendly interface with power & flexibility to increase the productivity of your research!
  • Spontaneous tracking
  • Advanced calculations
  • Superior zone editing
  • 2D and 3D mapping
  • Built-in DVR system


Announcing the new
PHD ULTRA™ Syringe Pumps

Click here for more information about PHD ULTRA™ Syringe Pumps and to download a brochure.

  • Patent pending mechanical design provides highest accuracy/precision & smoothest flow
  • Easy operation with advanced touch screen
  • Advanced EZ PRO™ software for PC functions without a PC.


Sign-up for a FREE Full Line Bioresearch Catalog
CLICK HERE!

  • Over 11,000 specialty products to enhance your bioresearch
  • Enhanced solutions for small animal research
  • 100's of pages of specialized information on instrumentation, applications, uses of products

 

Products on this website are for Research Use Only. Not for use in humans unless
proper investigational device regulations have been followed.


Privacy Policy   |   Terms and Conditions   
Copyright© Harvard Apparatus Ltd. - All rights reserved.
(44) 1732-864001
Website-related comments or concerns can be emailed to our webmaster.

Anesthesia Equipment Animal Handling Products Behavior Research Products Biological Measurement Products Cardiovascular Products Cell Biology Products Microincubation / Microinjectors CPK® Atomic Models Delivery & Sampling Products Dialysis / Sample Prep / SPE Electroporation / Transfection Electrophysiology Products General Laboratory Products Homeothermic/Temperature Control Isolated Organ & Isolated Tissue Molecular Biology Products Neuroscience Products Non-Invasive Blood Pressure Physiology Products Respiratory Products Stereotaxic Instruments Surgical Equipment Surgical Instruments Syringe Pumps/Peristaltic Pumps Tubing & Connectors Ventilators