Welcome to Harvard Apparatus Limited! Login / Register
Search

Search for these keywords
Home Catalogs Online Technical Resources My Account
Advanced Search   
Products by Category

Featured Products
Warner Cell Electrophysiology & Cell Biology Research
Hugo Sachs Elektronic Isolated Organ and Tissue Systems
BTX Electroporation and Electrofusion Products
Panlab Behavior Research Products
Hoefer Electrophoresis Products
Coulbourn Instruments
Clark Glass Products
Navicyte Ussing/Diffusion Chambers
CMA
Harvard Apparatus
 

Home Delivery & Sampling Products Vascular Access Ports Small Vascular Access Ports Small Vascular Access Ports with Detachable Catheters


Larger Views

 

Small Vascular Access Ports with Detachable Catheters

The vascular access port has evolved from being an intravascular access port into a multi-purpose access port for use in intestinal, biliary, intraspinal, cranial, ventricular, and other applications. It is available in a variety of configurations for most species and catheter sizes. The catheter may be pre-attached during manufacture or attached intraoperatively by the surgeon. These ports are fabricated from the highest quality biomaterials.
Search for Product in current catalog
Item Listing Full Description Specifications Journal Articles Manuals
Item# Description
724363 Small Vascular Access Port with Detachable Silastic Catheter, 3 Fr, pkg. of 1
724364 Small Vascular Access Port with Detachable Silastic Catheter, 3.5 Fr, pkg. of 1
724365 Small Vascular Access Port with Detachable Silastic Catheter, 5 Fr, pkg. of 1
724366 Small Vascular Access Port with Detachable Silastic Catheter, 7 Fr, pkg. of 1
724367 Small Vascular Access Port with Detachable CBAS-coated PU Catheter, 3 Fr, pkg. of 1
724368 Small Vascular Access Port with Detachable CBAS-coated PU Catheter, 3.5 Fr, pkg. of 1
724369 Small Vascular Access Port with Detachable CBAS-coated PU Catheter, 5 Fr, pkg. of 1
724370 Small Vascular Access Port with Detachable CBAS-coated PU Catheter, 7 Fr, pkg. of 1
724371 Small Vascular Access Port with Detachable Uncoated PU Catheter, 3 Fr, pkg. of 1
724372 Small Vascular Access Port with Detachable Uncoated PU Catheter, 3.5 Fr, pkg. of 1
724373 Small Vascular Access Port with Detachable Uncoated PU Catheter, 5 Fr, pkg. of 1
724374 Small Vascular Access Port with Detachable Uncoated PU Catheter, 7 Fr, pkg. of 1

For local pricing, contact your nearest distributor.



Full Description Back to Top

• Easy to Use
• MRI compatible
• For use with small primates, rodents and other small species

The vascular access port has evolved from being an intravascular access port into a multi-purpose access port for use in intestinal, biliary, intraspinal, cranial, ventricular, and other applications. It is available in a variety of configurations for most species and catheter sizes. The catheter may be pre-attached during manufacture or attached intraoperatively by the surgeon. These ports are fabricated from the highest quality biomaterials.
Ports are entirely implanted catheter devices which do not exit through the animal’s skin. There is little concern about the animal disturbing the port thereby obviating the need for a jacket or other protective apparatus. Because there is no chronic exit site wound, infection risks associated with ports are considerably lower than with external catheters. The use of ports has provided many new research opportunities, and it represents a refined technique which has reduced animal use and minimized stress.
The port was originally intended for intermittent bolus infusions and periodic sampling and access, but it is now widely used in protracted and continuous infusions. The port is also used in a tethered model for longer boluses (one hour, for example) or for intermittent periods of blood pressure monitoring.
Catheter Biomaterials
The field of biomaterials for intravascular catheters has moved relatively slowly over the past three decades. Silicone rubber continues to be the most common material; however, polyurethanes have proven to be more hemocompatible than silicone. And the CBAS™ heparin coated polyurethane has proven to be the most thromboresistant material of all available technologies. This catalog offers a full range of silicone, polyurethane, and CBAS™-coated polyurethane catheters in sizes for all species.
Rounded Tips
Another vital catheter feature is the rounded distal tip. Both data and intuition confirm the benefits. The rounded tip is less traumatic to the intimal lining of blood vessels. Square cut or bevel cut catheters have sharp edges which irritate the blood vessel’s intimal lining thus hastening the host’s thrombogenic response. Rounded tips are available on polyurethane and CBAS™-coated polyurethane catheters.
CBAS™ Long-Term Heparin Coating
The Carmeda BioActive Surface (CBAS™) is the product of Carmeda AB in Stockholm, Sweden. Carmeda has an extensive bibliography of CBAS™ applications, particularly in human-use devices. CBAS™ applications in humans include central venous catheters, coronary stents, ventricular assist devices, extracorporeal blood circuits, blood sampling devices, and vascular grafts. CBAS™ is used to coat devices from J&J, Medtronic, and Gore. In lab animal research, CBAS™-coated catheters are used for arterial and venous access. Also, CBAS™ provides dramatic improvement in catheter patency for chronic lymphatic access.
CBAS™ is a patented process for applying heparin to the surfaces of biomaterials. Unlike TDMAC heparin, the CBAS™ covalent bonds last several months. The "active sequence" of the heparin molecule serves to halt the clotting cascade.
The endothelial lining of blood vessels contains a heparin-like substance which performs like CBAS™. The novel aspect of CBAS™ is that the active sequence remains available over and over to bind with antithrombin. No other coating can achieve this long-term function.
CBAS™ is the most respected thromboresistant coating available in the human-use medical device industry. Unlike hydrogels, CBAS™ is bioactive, not passive. It has been proven repeatedly to minimize the thrombogenecity of intravascular devices.
CBAS™ is not consumed. The heparin "active sequence" repeatedly binds to antithrombin to prevent clotting. As such, half-life is not an issue. CBAS™ is "end-point attached" to the catheter surface and does not elute into the bloodstream.


Specifications Back to Top

Specifications724363724364724365724366724367724368724369724370724371724372724373724374
SizeSmallSmallSmallSmallSmallSmallSmallSmallSmallSmallSmallSmall
MaterialTitanium Port, Silastic CatheterTitanium Port, Silastic CatheterTitanium Port, Silastic CatheterTitanium Port, Silastic CatheterTitanium Port, CBAS-coated Polyurethane CatheterTitanium Port, CBAS-coated Polyurethane CatheterTitanium Port, CBAS-coated Polyurethane CatheterTitanium Port, CBAS-coated Polyurethane CatheterTitanium Port, Uncoated Polyurethane CatheterTitanium Port, Uncoated Polyurethane CatheterTitanium Port, Uncoated Polyurethane CatheterTitanium Port, Uncoated Polyurethane Catheter
SterilizationEtO SteamEtO SteamEtO SteamEtO SteamEtOEtOEtOEtOEtOEtOEtOEtO
ConfigurationDetachable catheterDetachable catheterDetachable catheterDetachable catheterDetachable catheterDetachable catheterDetachable catheterDetachable catheterDetachable catheterDetachable catheterDetachable catheterDetachable catheter
Catheter Size3 Fr3.5 Fr5 Fr7 Fr3 Fr3.5 Fr5 Fr7 Fr3 Fr3.5 Fr5 Fr7 Fr
Height English0.257 in0.257 in0.257 in0.257 in0.257 in0.257 in0.257 in0.257 in0.257 in0.257 in0.257 in0.257 in
Height Metric7.0 mm7.0 mm7.0 mm7.0 mm7.0 mm7.0 mm7.0 mm7.0 mm7.0 mm7.0 mm7.0 mm7.0 mm
Weight (Port Body) Metric2.9 g2.9 g2.9 g2.9 g2.9 g2.9 g2.9 g2.9 g2.9 g2.9 g2.9 g2.9 g
Port Volume Metric0.13 ml0.13 ml0.13 ml0.13 ml0.13 ml0.13 ml0.13 ml0.13 ml0.13 ml0.13 ml0.13 ml0.13 ml
Port ModelTitaniumTitaniumTitaniumTitaniumTitaniumTitaniumTitaniumTitaniumTitaniumTitaniumTitaniumTitanium
Top Diameter Metric1.0 cm1.0 cm1.0 cm1.0 cm1.0 cm1.0 cm1.0 cm1.0 cm1.0 cm1.0 cm1.0 cm1.0 cm
Top Diameter English0.4 in0.4 in0.4 in0.4 in0.4 in0.4 in0.4 in0.4 in0.4 in0.4 in0.4 in0.4 in
Base Diameter Metric1.7 cm1.7 cm1.7 cm1.7 cm1.7 cm1.7 cm1.7 cm1.7 cm1.7 cm1.7 cm1.7 cm1.7 cm
Base Diameter English0.7 in0.7 in0.7 in0.7 in0.7 in0.7 in0.7 in0.7 in0.7 in0.7 in0.7 in0.7 in
Punctures with 22 G Huber Point Needle100010001000100010001000100010001000100010001000
Catheter Length Metric60 cm, with 2 retention beads60 cm, with 2 retention beads60 cm, with 2 retention beads60 cm, with 2 retention beads60 cm, with 2 retention beads60 cm, with 2 retention beads60 cm, with 2 retention beads60 cm, with 2 retention beads60 cm, with 2 retention beads60 cm, with 2 retention beads60 cm, with 2 retention beads60 cm, with 2 retention beads
Catheter Length English24 in, with 2 retention beads24 in, with 2 retention beads24 in, with 2 retention beads24 in, with 2 retention beads24 in, with 2 retention beads24 in, with 2 retention beads24 in, with 2 retention beads24 in, with 2 retention beads24 in, with 2 retention beads24 in, with 2 retention beads24 in, with 2 retention beads24 in, with 2 retention beads
ApplicationsFerret, NHP (? 3 kg)Ferret, NHP (? 3 kg)Ferret, NHP (? 3 kg)Ferret, NHP (? 3 kg)Ferret, NHP (? 3 kg)Ferret, NHP (? 3 kg)Ferret, NHP (? 3 kg)Ferret, NHP (? 3 kg)Ferret, NHP (? 3 kg)Ferret, NHP (? 3 kg)Ferret, NHP (? 3 kg)Ferret, NHP (? 3 kg)

Back to Top



Journal Articles Back to Top

Displaying 1 to 10 of 28results for Small Vascular Access Ports with Detachable Catheters   Page 1  2  3 

Score

Document

Description

100% Login to view VT12 Small rodent ventilator use in finding chronic measurement of cardiac output in conscious mice.pdf
[184 KB]
Small rodent ventilator use in finding chronic measurement of cardiac output in conscious mice
81% Login to view VT11 Effects of Concentrated Ambient Particles in rats and Hamsters with Small Animal Respirator.pdf
[874 KB]
Effects of Concentrated Ambient Particles in rats and Hamsters with Small Animal Respirator
60% Login to view HS01 Opioids and Coronary Vascular Tone.pdf
[138 KB]
Force Transducer influence of opioids on the vascular tone of isolated porcine coronary artery segments
60% Login to view VT12 mini 2002hs.pdf
[177 KB]
Small rodent ventilator use in finding chronic measurement of cardiac output in conscious mice
45% Login to view VT32 Digital Optical Imaging to Track Vascular Gene Expression.pdf
[1,004 KB]
Digital Optical Imaging to Track Vascular Gene Expression
44% Login to view VT23 Inhibition Shapes Frequency Response Areas with Small Animal Ventilator.pdf
[673 KB]
Inhibition Shapes Frequency Response Areas with Small Animal Ventilator
42% Login to view VT11SM 1.PDF
[860 KB]
Effects of Concentrated Ambient Particles in rats and Hamsters with Small Animal Respirator
35% Login to view VT30 Rodent Ventilator use in Antisense Knockdown of the Gial Glutamate Transporter GLT-1.pdf
[366 KB]
Rodent Ventilator use in Antisense Knockdown of the Gial Glutamate Transporter GLT-1
31% Login to view VT32 mri vent.pdf
[1.1 MB]
Digital Optical Imaging to Track Vascular Gene Expression
30% Login to view PP85.pdf
[722 KB]
Portosystemic shunting and persistent fetal vascular structures in aryl hydrocarbon receptor-deficient mice
   

Back to Top



Manuals Back to Top

Displaying 1 to 2 of 2results for Small Vascular Access Ports with Detachable Catheters  

Score

Document

Description

100% Login to view 550000 Ventilator 683 Manual.pdf
[363 KB]
Model 683 Small Animal Ventilator User's Manual
74% Login to view Model680 553438.pdf
[66 KB]
Model 680 Small Animal Ventilator Manual
   

Back to Top

Breakthrough Products for Regenerative Medicine
2011 Regenerative Medicine Brochure
100's of Innovative products developed with leading scientists & surgeons!
  • Injection & Perfusion
  • Bioreactors
  • Biosensing
  • Total Solutions
  • Total Support


Announcing the new
PHD ULTRA™ Syringe Pumps

Click here for more information about PHD ULTRA™ Syringe Pumps and to download a brochure.

  • Patent pending mechanical design provides highest accuracy/precision & smoothest flow
  • Easy operation with advanced touch screen
  • Advanced EZ PRO™ software for PC functions without a PC.


Sign-up for a FREE Full Line Bioresearch Catalog
CLICK HERE!

  • Over 11,000 specialty products to enhance your bioresearch
  • Enhanced solutions for small animal research
  • 100's of pages of specialized information on instrumentation, applications, uses of products

 

Products on this website are for Research Use Only. Not for use in humans unless
proper investigational device regulations have been followed.


Privacy Policy   |   Terms and Conditions   
Copyright© Harvard Apparatus Ltd. - All rights reserved.
(44) 1732-864001
Website-related comments or concerns can be emailed to our webmaster.

Anesthesia Equipment Animal Handling Products Behavior Research Products Biological Measurement Products Cardiovascular Products Cell Biology Products Microincubation / Microinjectors CPK® Atomic Models Delivery & Sampling Products Dialysis / Sample Prep / SPE Electroporation / Transfection Electrophysiology Products General Laboratory Products Homeothermic/Temperature Control Isolated Organ & Isolated Tissue Molecular Biology Products Neuroscience Products Non-Invasive Blood Pressure Physiology Products Respiratory Products Stereotaxic Instruments Surgical Equipment Surgical Instruments Syringe Pumps/Peristaltic Pumps Tubing & Connectors Ventilators