Home Biological Measurement Products pH Meters pH Controllers pH Controllers with Dual Setpoint


Larger Views

 

pH Controllers with Dual Setpoint

pH 500 series of controllers offer exceptional value for your money. They are simple-to-operate, microprocessor-based process meters packed with features for the biological laboratory. For more flexibility and better resolution than chart recorders, any two points between 0 and 14 pH can be chosen to correspond to the analog output spans. Several pH 500 models are equipped with a bi-directional RS232C port. Push button password programming prevents tampering. The microprocessor memory is fully programmable and has 3 months backup power supply. The Fail Safe Alarm system protects the pH 500 against the pitfalls of process control, like power interruption or line failure. With pH 500 quick 1, 2 or 3 point calibration at pH 4.01, 7.01 and 10.01 comes standard. The temperature can be manually or automatically compensated for. Increased automation has made computer compatibility a necessity for process control instrumentation.
Search for Product in current catalog
Item Listing Full Description Specifications Journal Articles Manuals
Item# Description
722011 pH 500 Controller, Dual Setpoint, Analog Output, On/Off Controls, 115 VAC, 60 Hz
722012 pH 500 Controller, Dual Setpoint, Analog Output, On/Off Controls, 230 VAC, 50 Hz
722013 pH 500 Controller, Dual Setpoint, RS232 Output, On/Off Controls, 115 VAC, 60 Hz
722014 pH 500 Controller, Dual Setpoint, RS232 Output, On/Off Controls, 230 VAC, 50 Hz
722015 pH 500 Controller, Dual Setpoint, Analog Output, Proportional Controls, 115 VAC, 60 Hz
722016 pH 500 Controller, Dual Setpoint, Analog Output, Proportional Controls, 230 VAC, 50 Hz
722017 pH 500 Controller, Dual Setpoint, RS232 Output, Proportional Controls, 115 VAC, 60 Hz
722018 pH 500 Controller, Dual Setpoint, RS232 Output, Proportional Controls, 230 VAC, 50 Hz

For local pricing, contact your nearest distributor.



Full Description Back to Top

• Hi-tech pH 500 controller
• The new measure of value
• Simple to operate
• Microprocessor-based

pH 500 series of controllers offer exceptional value for your money. They are simple-to-operate, microprocessor-based process meters packed with features for the biological laboratory. For more flexibility and better resolution for chart recorders, any two points between 0 and 14 pH can be chosen to correspond to the analog output spans. Several pH 500 models are equipped with a bi-directional RS232C port. Push button password programming prevents tampering. The microprocessor memory is fully programmable and has 3 months backup power supply. The Fail Safe Alarm system protects the pH 500 against the pitfalls of process control, like power interruption or line failure. With pH 500 quick 1, 2 or 3 point calibration at pH 4.01, 7.01 and 10.01 comes standard. The temperature can be manually or automatically compensated for. Increased automation has made computer compatibility a necessity for process control instrumentation.
This unit can be adapted to control the pH of biological preparations such as cell cultures by controlling flow of a pH reducing gas such as CO2. The CO2 gas can be regulated by on/off proportional control to save gas.


Specifications Back to Top

Specifications722011722012722013722014722015722016722017722018
pH Range0.00 to 14.000.00 to 14.000.00 to 14.000.00 to 14.000.00 to 14.000.00 to 14.000.00 to 14.000.00 to 14.00
mV Range-600.0 t0 600.0-600.0 t0 600.0-600.0 t0 600.0-600.0 t0 600.0-600.0 t0 600.0-600.0 t0 600.0-600.0 t0 600.0-600.0 t0 600.0
Temperature Range (°C)-9.9° to 120.0°-9.9° to 120.0°-9.9° to 120.0°-9.9° to 120.0°-9.9° to 120.0°-9.9° to 120.0°-9.9° to 120.0°-9.9° to 120.0°
pH Resolution0.010.010.010.010.010.010.010.01
mV Resolution0.20.20.20.20.20.20.20.2
Temperature Resolution (°C)0.1°0.1°0.1°0.1°0.1°0.1°0.1°0.1°
Accuracy of pH at 20°C/68°F±0.02±0.02±0.02±0.02±0.02±0.02±0.02±0.02
Accuracy of mV at 20°C/68°F±0.5±0.5±0.5±0.5±0.5±0.5±0.5±0.5
Accuracy of temperature (°C) at 20°C/68°F±0.5°±0.5°±0.5°±0.5°±0.5°±0.5°±0.5°±0.5°
Typical EMC Deviation of pH±0.02±0.02±0.02±0.02±0.02±0.02±0.02±0.02
Typical EMC Deviation of mV±10±10±10±10±10±10±10±10
Typical EMC Deviation of Temperature (°C)±0.5°±0.5°±0.5°±0.5°±0.5°±0.5°±0.5°±0.5°
pH Calibration1, 2 or 3 point with buffers 4.01, 7.01 and 10.011, 2 or 3 point with buffers 4.01, 7.01 and 10.011, 2 or 3 point with buffers 4.01, 7.01 and 10.011, 2 or 3 point with buffers 4.01, 7.01 and 10.011, 2 or 3 point with buffers 4.01, 7.01 and 10.011, 2 or 3 point with buffers 4.01, 7.01 and 10.011, 2 or 3 point with buffers 4.01, 7.01 and 10.011, 2 or 3 point with buffers 4.01, 7.01 and 10.01
LoggingAutomatic (with Pt 100) or manual from -9.9° to 120°Automatic (with Pt 100) or manual from -9.9° to 120°Automatic (with Pt 100) or manual from -9.9° to 120°Automatic (with Pt 100) or manual from -9.9° to 120°Automatic (with Pt 100) or manual from -9.9° to 120°Automatic (with Pt 100) or manual from -9.9° to 120°Automatic (with Pt 100) or manual from -9.9° to 120°Automatic (with Pt 100) or manual from -9.9° to 120°
Readout4° digit dual level LCD with graphic symbols and messages4° digit dual level LCD with graphic symbols and messages4° digit dual level LCD with graphic symbols and messages4° digit dual level LCD with graphic symbols and messages4° digit dual level LCD with graphic symbols and messages4° digit dual level LCD with graphic symbols and messages4° digit dual level LCD with graphic symbols and messages4° digit dual level LCD with graphic symbols and messages
Input Impedance1012?1012?1012?1012?1012?1012?1012?1012?
Setpoint Relays1 or 2; SPST NO contact outputs 5 A-250 VAC, 5 A-30 VDC (resistive load)1 or 2; SPST NO contact outputs 5 A-250 VAC, 5 A-30 VDC (resistive load)1 or 2; SPST NO contact outputs 5 A-250 VAC, 5 A-30 VDC (resistive load)1 or 2; SPST NO contact outputs 5 A-250 VAC, 5 A-30 VDC (resistive load)1 or 2; SPST NO contact outputs 5 A-250 VAC, 5 A-30 VDC (resistive load)1 or 2; SPST NO contact outputs 5 A-250 VAC, 5 A-30 VDC (resistive load)1 or 2; SPST NO contact outputs 5 A-250 VAC, 5 A-30 VDC (resistive load)1 or 2; SPST NO contact outputs 5 A-250 VAC, 5 A-30 VDC (resistive load)
Battery Type115V ±10% VAC; 60 Hz230V ±10% VAC; 50 Hz115V ±10% VAC; 60 Hz230V ±10% VAC; 50 Hz115V ±10% VAC; 60 Hz230V ±10% VAC; 50 Hz115V ±10% VAC; 60 Hz230V ±10% VAC; 50 Hz
Environment (°C)0° to 50°0° to 50°0° to 50°0° to 50°0° to 50°0° to 50°0° to 50°0° to 50°
Environment (°F)32° to 122°32° to 122°32° to 122°32° to 122°32° to 122°32° to 122°32° to 122°32° to 122°
Environment (RH)85% non-condensing85% non-condensing85% non-condensing85% non-condensing85% non-condensing85% non-condensing85% non-condensing85% non-condensing
Digital OutputRS232 bi-directional opto-isolatedRS232 bi-directional opto-isolatedRS232 bi-directional opto-isolatedRS232 bi-directional opto-isolatedRS232 bi-directional opto-isolatedRS232 bi-directional opto-isolatedRS232 bi-directional opto-isolatedRS232 bi-directional opto-isolated
Analog OutputGalvanically isolated 0 to 1mA, 0 to 20mA and 4 to 20mA (max resistive load 1 KW), 0 to 5 VDC, 1 to 5 VDC and 0 to 10 VDC (min resistive load 1 KW)Galvanically isolated 0 to 1mA, 0 to 20mA and 4 to 20mA (max resistive load 1 KW), 0 to 5 VDC, 1 to 5 VDC and 0 to 10 VDC (min resistive load 1 KW)Galvanically isolated 0 to 1mA, 0 to 20mA and 4 to 20mA (max resistive load 1 KW), 0 to 5 VDC, 1 to 5 VDC and 0 to 10 VDC (min resistive load 1 KW)Galvanically isolated 0 to 1mA, 0 to 20mA and 4 to 20mA (max resistive load 1 KW), 0 to 5 VDC, 1 to 5 VDC and 0 to 10 VDC (min resistive load 1 KW)Galvanically isolated 0 to 1mA, 0 to 20mA and 4 to 20mA (max resistive load 1 KW), 0 to 5 VDC, 1 to 5 VDC and 0 to 10 VDC (min resistive load 1 KW)Galvanically isolated 0 to 1mA, 0 to 20mA and 4 to 20mA (max resistive load 1 KW), 0 to 5 VDC, 1 to 5 VDC and 0 to 10 VDC (min resistive load 1 KW)Galvanically isolated 0 to 1mA, 0 to 20mA and 4 to 20mA (max resistive load 1 KW), 0 to 5 VDC, 1 to 5 VDC and 0 to 10 VDC (min resistive load 1 KW)Galvanically isolated 0 to 1mA, 0 to 20mA and 4 to 20mA (max resistive load 1 KW), 0 to 5 VDC, 1 to 5 VDC and 0 to 10 VDC (min resistive load 1 KW)
Panel Output Metric140 x 140 mm140 x 140 mm140 x 140 mm140 x 140 mm140 x 140 mm140 x 140 mm140 x 140 mm140 x 140 mm
Panel Output English5.5 x 5.55.5 x 5.55.5 x 5.55.5 x 5.55.5 x 5.55.5 x 5.55.5 x 5.55.5 x 5.5
Meter Dimensions (H x W x D) Metric170 x 144 x 144170 x 144 x 144170 x 144 x 144170 x 144 x 144170 x 144 x 144170 x 144 x 144170 x 144 x 144170 x 144 x 144
Meter Dimensions (H x W x D) English6.7 x 5.7 x 5.7 in6.7 x 5.7 x 5.7 in6.7 x 5.7 x 5.7 in6.7 x 5.7 x 5.7 in6.7 x 5.7 x 5.7 in6.7 x 5.7 x 5.7 in6.7 x 5.7 x 5.7 in6.7 x 5.7 x 5.7 in
Weight Metric1.6 kg1.6 kg1.6 kg1.6 kg1.6 kg1.6 kg1.6 kg1.6 kg
Weight English3.5 lb3.5 lb3.5 lb3.5 lb3.5 lb3.5 lb3.5 lb3.5 lb

Back to Top



Journal Articles Back to Top

Displaying 1 to 5 of 5results for pH Controllers with Dual Setpoint  

Score

Document

Description

100% Login to view Noninvasive measurement of the pH of the endoplasmic reticulum.PDF
[372 KB]
Noninvasive measurement of the pH of the endoplasmic reticulum at rest and during calcium release
44% Login to view PDMI02 1.PDF
[360 KB]
Noninvasie measurement of the pH of the endoplasmic reticulim at rest and during calcium release
31% Login to view VT18 PDMI2 Microincubator.pdf
[456 KB]
PDMI-2 Microincubator use in Airway surface liquid pH in well-differentiated airway epithelial cell cultures and mouse trachea
26% Login to view PP107 mri pmp5.pdf
[295 KB]
Dual Syringe Pump use in finding Predictability Modulates Human Brain Response to Reward
13% Login to view VT14 Rodent Ventilator.pdf
[440 KB]
PDMI-2 Microincubator use in Airway surface liquid pH in well-differentiated airway epithelial cell cultures and mouse trachea
   

Back to Top



Manuals Back to Top

Displaying 1 to 4 of 4results for pH Controllers with Dual Setpoint  

Score

Document

Description

100% Login to view Swivel DualChannel 561282.pdf
[40 KB]
Swivel Dual Channel Manual
100% Login to view Swivel DualChannel 596705.pdf
[40 KB]
Swivel Dual Channel Manual
100% Login to view Swivel DualChannel 561431l.pdf
[40 KB]
Swivel Dual Channel Manual
91% Login to view Swivel DualChannel Repair.pdf
[37 KB]
Swivel Dual Channel Repair Manual
   

Back to Top

Breakthrough Products for Regenerative Medicine
2011 Regenerative Medicine Brochure
100's of Innovative products developed with leading scientists & surgeons!
  • Injection & Perfusion
  • Bioreactors
  • Biosensing
  • Total Solutions
  • Total Support


Announcing the new
PHD ULTRA™ Syringe Pumps

Click here for more information about PHD ULTRA™ Syringe Pumps and to download a brochure.

  • Patent pending mechanical design provides highest accuracy/precision & smoothest flow
  • Easy operation with advanced touch screen
  • Advanced EZ PRO™ software for PC functions without a PC.


Sign-up for a FREE Full Line Bioresearch Catalog
CLICK HERE!

  • Over 11,000 specialty products to enhance your bioresearch
  • Enhanced solutions for small animal research
  • 100's of pages of specialized information on instrumentation, applications, uses of products

 

Products on this website are for Research Use Only. Not for use in humans unless
proper investigational device regulations have been followed.


Privacy Policy   |   Terms and Conditions   
Copyright© Harvard Apparatus Ltd. - All rights reserved.
(44) 1732-864001
Website-related comments or concerns can be emailed to our webmaster.

Anesthesia Equipment Animal Handling Products Behavior Research Products Biological Measurement Products Cardiovascular Products Cell Biology Products Microincubation / Microinjectors CPK® Atomic Models Delivery & Sampling Products Dialysis / Sample Prep / SPE Electroporation / Transfection Electrophysiology Products General Laboratory Products Homeothermic/Temperature Control Isolated Organ & Isolated Tissue Molecular Biology Products Neuroscience Products Non-Invasive Blood Pressure Physiology Products Respiratory Products Stereotaxic Instruments Surgical Equipment Surgical Instruments Syringe Pumps/Peristaltic Pumps Tubing & Connectors Ventilators