MultiStim System for Tissue Bath Stimulation
Dual Channel Biphasic Switcher Module
|
|
Larger Views
|
Dual Channel Biphasic Switcher Module
This 2-Channel Bi-Phasic switcher is for use with a D333H or D343 module. The unit provides the switching function required to alternate the polarity of the stimuli to each of two preparations. It provides control of stimulus polarity (Normal, Alternating or Reverse) independently for each channel as well as warning of a stimulus timing rate that is too-fast. The control and timing for the pulses is generated by selecting other modules from the D330 - MultiStim™ range.
Search for Product in current catalog
|
|
|
|
This 2-Channel Bi-Phasic switcher is for use with a D333H or D343 module. The unit provides the switching function required to alternate the polarity of the stimuli to each of two preparations. It provides control of stimulus polarity (Normal, Alternating or Reverse) independently for each channel as well as warning of a stimulus timing rate that is too-fast. The control and timing for the pulses is generated by selecting other modules from the D330 - MultiStim™ range.
It should be noted that the unit works with mechanical relays that require a certain time to switch their polarity. The circuitry is designed so that the changeover command is taken (independently for each channel) from the end of each stimulus timing pulse so that the relay ‘moves’ when no stimulus is being applied.
As with all mechanical devices, relays have a finite life. This is quoted as a minimum of 100,000,000 mechanical operations. If the relay was to ‘move’ whilst a stimulus was presented the contacts would wear-out much quicker than the mechanics. Therefore, the circuit will detect and warn the user if the ‘time-between’ stimuli pulses is less than
5 ms. The user must ensure that this
never happens.
The module connects to the outputs of a D333H or D343 via 2 mm - 2 mm leads (supplied). The D333H/343 has the functions and specifications as defined in its specification part of this manual. Each module is preset for specific channels whose outputs are to be switched. Normally, the unit will be supplied preset for channels 1 and 2 or as required when a full system is purchased. That is, the timing signals of the D333H/343 and the D342 will automatically be the same. The channels set is shown at the top of the module front panel.
|
|
|
 |
|
NEW
Breakthrough Products for Regenerative Medicine
|
|
|
|
| 100's of Innovative products developed with leading scientists & surgeons! |
- Injection & Perfusion
- Bioreactors
- Biosensing
- Total Solutions
- Total Support
|
|
Announcing the new PHD ULTRA Syringe Pumps
|
Sign-up for a FREE Full Line Bioresearch Catalog
CLICK HERE!
- Over 11,000 specialty products to enhance your bioresearch
- Enhanced solutions for small animal research
- 100's of pages of specialized information on instrumentation, applications, uses of products
|
|
|
|