Multi-Equilibrium Dialyzer System

Multi-Equilibrium Dialyzer System

Provides highly standardized equilibrium dialysis conditions for up to 20 parallel assays.

The Multi-Equilibrium Dialyzer offers outstanding uniformity of membrane area, sample volume, and degree of agitation. Up to 20 cells can be used simultaneously for rapid equilibrium dialysis under standardized conditions. The dialyzer cells are constructed from inert PTFE allowing for maximum sample recovery.

Item# Description
74-1800 Multi-Equilibrium Dialyzer System, 1 ml, 10 kDa Membrane, 115 V
74-1810 Multi-Equilibrium Dialyzer System, 1 ml, 10 kDa Membrane, 230 V
74-1906 Macro PTFE Dialysis Cells (1 ml) , pkg. of 5
74-1904 Macro PTFE Dialysis Cells (2 ml), pkg. of 5
74-1905 Macro PTFE Dialysis Cells (5 ml), pkg. of 5
74-1907 Micro PTFE Dialysis Cells (0.25 ml), pkg. of 5
74-1909 Macro Spacer, pkg. of 6
74-1908 Micro Spacer, pkg. of 6
74-1911 Macro Cell Carrier, pkg. of 1
74-1910 Micro Cell Carrier, pkg. of 1
74-1913 Filling Clamp, pkg. of 1
74-1914 Black Stoppers, pkg. of 32
74-1919 Tank with Fittings (14.5 x 9.5 x 8.25 in), pkg. of 1
74-1901 Emptying Stoppers, pkg. of 5
74-2102 Membranes for Multi-Equilibrium DIALYZERS and/or Mini Lipoprep, 10000 Dalton MWCO Membrane, Qty. of 200
For local pricing, contact your nearest distributor.

The Multi-Equilibrium Dialyzer provides rapid, highly standardized equilibrium dialysis for up to 20 parallel assays. The instrument offers outstanding uniformity of membrane area, sample volume, and degree of agitation.

The dialyzer cells are constructed from inert PTFE allowing for maximum sample recovery. Cell systems are available in groups of 5, 10, 15, or 20 cells, for sample volumes 0.2, 1.0, 2.0 or 5.0 ml. All cells can be easily filled with the filling clamp and are constructed of inert, leak free PTFE. 

Easy to use:

  • Leak-proof
  • Reproducible
  • Fast dialysis times
  • Available for a range of sample sizes
  • Up to 20 parallel, simultaneous assays
  • Autoclavable
  • Low protein binding
  • High sample recovery
  • Made of Teflon – totally inert

Applications:

  • Protein binding assays
  • Protein-drug binding assays
  • Receptor binding assays
  • Ligand binding assays
  • Protein-protein Interactions 
  • Protein-DNA Interactions

Complete Multi-Equilibrium Dialyzer Systems include:

  • Ready-to-use PTFE macro dialysis cells (1 ml volume) with large surface area and plugs, four sets of five (pkg. of 20)
  • Macro Spacers (pkg. of 240
  • Carriers for 5 Teflon Dialysis Cells (pkg. of 4)
  • Variable Speed Drive Unit (12 x 12 x 7.5 in)
  • AC adapter, 115 VAC (74-1810) or 230 VAC (74-1800)
  • Power Supply Adapter (110 V or 230V)
  • Stand (1)
  • Filling Clamp (1)
  • Emptying Stoppers (pkg. of 2)
  • Dialysis Membranes, MWCO 10 kDa (pkg. of 200)

 

Specifications