Home Specialty Vertical Ussing/Diffusion Chamber Systems


Larger Views

 

Specialty Vertical Ussing/Diffusion Chamber Systems

The vertical diffusion chamber system is used for transport studies on both filter grown cell monolayers and surgically excised tissue sections. The vertical diffusion chamber system consists of six diffusion chambers, a 12-channel gas manifold and a heat block. 14 general types of vertical chambers are currently available: one for use with cells grown on Snapwell™ membrane supports and the others for use with tissue.
Search for Product in current catalog
Item Listing Full Description Specifications Journal Articles Manuals
Item# Description
660001 Specialty Vertical Chamber System with Six 66-0008 - Snapwell™ Chambers

For local pricing, contact your nearest distributor.



Full Description Back to Top

• The standard assay for oral bioavailability
• Applications include:
- Drug delivery
- Toxicology
- Pharmacokinetics
- Metabolic studies
- Transport
• US Patented technology numbers: 5, 183, 760 and 5,591,636
• Available in vertical and horizontal system configurations
• Options for using cultured cells or tissue samples
• Manufactured entirely of acrylic for reduced drug absorption/easy cleaning
• Compact configurations
• Up to 24 chambers can be run simultaneously
• Systems are temperature controlled
• Electrode ports connect optional electrodes for monolayer resistance measurements and electrophysiological determinations • Designed for easy placement of Snapwell™ (grown cells) or tissue sections
• All Snapwell™ and tissue diffusion chamber config-urations are compatible with the vertical system, providing versatility and convenience for correlation studies
• Side-by-side orientation prevents a hydrostatic pressure gradient across cell layer
• Distributes gas (user supplied) to the diffusion chambers where media circulation is generated by gas lift, reducing unstirred fluid layers adjacent to cells
• Individual control valves on gas manifold allow independent adjustment of gas flow into each diffusion chamber half-cell
• Closed perfusion capable

The vertical diffusion chamber system is used for transport studies on both filter grown cell monolayers and surgically excised tissue sections. The vertical diffusion chamber system consists of six diffusion chambers, a 12-channel gas manifold and a heat block. 14 general types of vertical chambers are currently available: one for use with cells grown on Snapwell™ membrane supports and the others for use with tissue.
Gas Manifold
The 12-channel gas manifold distributes gas (user supplied) to the Diffusion Chambers where media circulation is generated by gas lift, reducing unstirred fluid layers adjacent to cells.
Heat Block
The dual heating blocks of the Vertical Chamber System provide efficient and precise heating or cooling of the Diffusion Chamber System. Temperature is controlled by use of a circulating water bath. The Heat Block and Gas Manifold allows six simultaneous tests to be run, improving experimental precision.
Electrode Caps
Electrode caps permit proper positioning of electrodes within the vertical perfusion chambers. They are required for the Snapwell™
BS4 66-0008, 8 x 24 mm Tissue 66-0013 and 9 mm Round
BS4 66-0014 chambers. They are not required for the low volume chambers or the horizontal tissue chambers.
Perfusion Caps
The BS4 66-0019 perfusion cap allow the tissue chambers to be perfused with media using a peristaltic or syringe pump. They are required for use with the Snapwell™ 66-0008, 8 x 24 mm Tissue 66-0013, and 9 mm Round 66-0014 chambers. They are not required for the low volume chambers or the horizontal tissue chambers. We offer 14 different vertical diffusion chambers. We also offer a complete system for each chamber that includes the following components:
Catalog No. Qty. Product
66-0009 1 6-Chamber Heating Block
66-0010 1 Clear Front Panel
66-0048 1 12-Channel Gas Manifold
66-0012 1 Retaining Ring Clamp Tool
Specified 6 Vertical Diffusion Chambers


Specifications Back to Top

Specifications660001
660013_gr_il_150.jpg660013_gr_il_150.jpg
Exposed Tissue Area1.13 cm2
Working Reservoir Volume4 to 6 ml
Chamber TypeSnapwell™

Back to Top



Journal Articles Back to Top

Displaying 11 to 19 of 19results for Specialty Vertical Ussing/Diffusion Chamber Systems   Page 1  2 

Score

Document

Description

37% Login to view macro fast dispo dial.pdf
[241 KB]
Cisplatin delivery from poly(acrylic acid-co-methyl methacrylate) microparticles
33% Login to view HB01 Assessment of Tissue Oxygen Tension.pdf
[270 KB]
Homeothermic Blanket Assessment of tissue oxygen tension
33% Login to view HB03 Leukotriene B4 Promotes Reactive Oxidant Generation and Leukocyte Adherence During Acute Hypoxia.pdf
[198 KB]
Homeothermic Blanket Leukotrience B4 promotes reactive oxidant generation and leukocyte adherence during acute hypoxia
33% Login to view HB08 mri bkt 3.pdf
[272 KB]
VEGF antagonism reduces edema formation and tissue damage after ischemia/reperfusion injury in the mouse brain
33% Login to view HB09 Two-Photon Imaging of Capillary Blood Flow in Olfactory Bulb Glomeruli.pdf
[989 KB]
Two-photon imaging of capillary blood flow in olfactory bulb golmeruli
30% Login to view Kainate Receptor Activation.pdf
[878 KB]
AMPA Kainate Receptor Activation Mediates Hypoxic Oligodendrocyte Death and Axonal Injury in Cerebral White Matter
30% Login to view electroprep3.pdf
[375 KB]
Binding of pregnancy-specific glycoprotein 17 to CD9 on macrophages induces secretion of IL-10, IL-6, PGE2,and TGF-B 1
26% Login to view MC01 Impaired Stratum Corneum Hydration in Mice Lacking Epidermal Water Channel Aquaporin-3.pdf
[339 KB]
Metabolic Cages use in finding Impaired Stratum Corneum Hydration in Mice Lacking Epidermal Water Channel Aquaporin-3
15% Login to view flow thru dial.pdf
[387 KB]
A Novel Approach for the Extraction and Concentration of Compounds in Biological Fluids via On-Line Dialysis and Enrichment
   

Back to Top



Manuals Back to Top

Displaying 1 to 1 of 1result for Specialty Vertical Ussing/Diffusion Chamber Systems  

Score

Document

Description

100% Login to view Ussing Chamber Systems.pdf
[1.5 MB]
Guide to Ussing Chamber Systems
   

Back to Top

Breakthrough Products for Regenerative Medicine
2011 Regenerative Medicine Brochure
100's of Innovative products developed with leading scientists & surgeons!
  • Injection & Perfusion
  • Bioreactors
  • Biosensing
  • Total Solutions
  • Total Support


Announcing the new
PHD ULTRA™ Syringe Pumps

Click here for more information about PHD ULTRA™ Syringe Pumps and to download a brochure.

  • Patent pending mechanical design provides highest accuracy/precision & smoothest flow
  • Easy operation with advanced touch screen
  • Advanced EZ PRO™ software for PC functions without a PC.


Sign-up for a FREE Full Line Bioresearch Catalog
CLICK HERE!

  • Over 11,000 specialty products to enhance your bioresearch
  • Enhanced solutions for small animal research
  • 100's of pages of specialized information on instrumentation, applications, uses of products

 

Products on this website are for Research Use Only. Not for use in humans unless
proper investigational device regulations have been followed.


Privacy Policy   |   Terms and Conditions   
Copyright© Harvard Apparatus Ltd. - All rights reserved.
(44) 1223-423723
Website-related comments or concerns can be emailed to our webmaster.

Anesthesia Equipment Animal Handling Products Behavior Research Products Biological Measurement Products Cardiovascular Products Cell Biology Products Microincubation / Microinjectors CPK® Atomic Models Delivery & Sampling Products Dialysis / Sample Prep / SPE Electroporation / Transfection Electrophysiology Products General Laboratory Products Homeothermic/Temperature Control Isolated Organ & Isolated Tissue Molecular Biology Products Neuroscience Products Non-Invasive Blood Pressure Physiology Products Respiratory Products Stereotaxic Instruments Surgical Equipment Surgical Instruments Syringe Pumps/Peristaltic Pumps Tubing & Connectors Ventilators