Chamber System Heater Controllers

These heater controllers have been designed to provide quiet, electric power to a variety of perfusion heating devices including Warner Series 20 heater platforms, solution in-line heaters and the DH-35 culture dish heater, see page M92.
We now offer two high temperature modifcation models of this Heater Controller. These model are useful for applications involving the study of the capsaicin receptors.

Search for Product in current catalog
Item Listing Full Description Specifications Journal Articles Manuals
Item# Description
640100 Model TC-324B Heater Controller, Single Channel
640101 Model TC-344B Heater Controller, Dual Channel
641453 Model TC-324BHT Perfusion Heater Controller Single Channel with High Temp Modification, 65C
641454 Model TC-344BHT Perfusion Heater Controller Dual Channel with High Temp Modification, 65C

For local pricing, contact your nearest distributor.



Full Description Back to Top

• Slow ramped DC power for quiet operation
• Temperature set with single control
• Manually controlled DC output
• High Temperature models available

These heater controllers have been designed to provide quiet, electric power to a variety of perfusion heating devices including Warner Series 20 heater platforms, solution in-line heaters and the DH-35 culture dish heater, see page M92.
We now offer two high temperature modifcation models of this Heater Controller. These model are useful for applications involving the study of the capsaicin receptors.
Each channel can supply up to 18 watts into a load of 8 ?. Maintenance of heat setpoint is controlled automatically in AUTO mode via thermistor feedback. A loop-speed selector allows for selection of three feedback speeds to optimize stability for thermal response characteristics of the device being heated. Heat setpoint maintenance may also be manually controlled in MANUAL mode.

Ease of Use
In AUTO mode, the desired temperature is set with a single SET TEMPERATURE control. The connected chamber platform, solution heater or other device is automatically controlled to the set temperature. Accuracy is typically better than 1C and under ideal conditions will approach 0.1C. In MANUAL mode, the controller provides a variable DC output adjustable from zero to +12 volts.

Quiet Operation in Recording Setups
Highly filtered DC supplies and slow-ramped analog switching circuitry deliver power without adding noise to the system.
Thermistor Readouts

Each channel reads two thermistors simultaneously: T1 for the control of the system, and a T2 for any point of interest. These temperatures are read on the meter and also available at front panel outputs for recording devices. Unical thermistors are used and can be replaced without the need for recalibration.


Specifications Back to Top

Specifications640100640101641453641454
ModelTC-324BTC-344BTC-324BHTTC-344BHT
CertificationsCECECECE
Height Metric8.9 cm8.9 cm8.9 cm8.9 cm
Width Metric20.0 cm43.0 cm20.0 cm43.0 cm
Depth Metric25.4 cm25.4 cm25.4 cm25.4 cm
Weight Metric3.6 kg6.8 kg3.6 kg6.8 kg
Max. Ouput Voltage12 V DC12 V DC12 V DC12 V DC
Max. Output Current1.5 Amps1.5 Amps1.5 Amps1.5 Amps
Max. Output Power18 W (8 ? load)18 W (8 ? load)18 W (8 ? load)18 W (8 ? load)
Manual Voltage Range0 to 12 V0 to 12 V0 to 12 V0 to 12 V
Recoder Outputs: Control Temp. OutT1 (Control Thermistor) 100 mV/CT1 (Control Thermistor) 100 mV/CT1 (Control Thermistor) 100 mV/CT1 (Control Thermistor) 100 mV/C
Recoder Outputs: Monitor Temp. OutT2 (Monitor Thermistor) 100 mV/CT2 (Monitor Thermistor) 100 mV/CT2 (Monitor Thermistor) 100 mV/CT2 (Monitor Thermistor) 100 mV/C
Inputs: Rear Panel BNCRear Panel BNC for T2 (TA-29 Thermistor Cable assembly)Rear Panel BNC for T2 (TA-29 Thermistor Cable assembly)Rear Panel BNC for T2 (TA-29 Thermistor Cable assembly)Rear Panel BNC for T2 (TA-29 Thermistor Cable assembly)
Meter3 1/2 digit LED display of:
Set Temperature, 50C max.
T1 (Control Thermistor) temp.
T2 (Monitor Thermistor) temp.
Heater Voltage, 12 V max
3 1/2 digit LED display of:
Set Temperature, 50C max.
T1 (Control Thermistor) temp.
T2 (Monitor Thermistor) temp.
Heater Voltage, 12 V max
3 1/2 digit LED display of:
Set Temperature, 50C max.
T1 (Control Thermistor) temp.
T2 (Monitor Thermistor) temp.
Heater Voltage, 12 V max
3 1/2 digit LED display of:
Set Temperature, 50C max.
T1 (Control Thermistor) temp.
T2 (Monitor Thermistor) temp.
Heater Voltage, 12 V max

Back to Top



Journal Articles Back to Top

Displaying 21 to 30 of 30results for Chamber System Heater Controllers   Page 1  2  3 

Score

Document

Description

24% Login to view WR04PL 1.PDF
[495 KB]
Two Distinct Ca2+ - Dependent Signaling Pathways regulate the Motor Output of Cochlear Outer Hair Cells with Pneumatic Injection System
22% Login to view HS14 Hyperventilation and Cytokine Release.pdf
[422 KB]
Ventilator and Amplifier use in Hyperventilation Inducing release of Cytokines from Perfused Mouse Lung
22% Login to view Action of 2,3-butanedione monoxime on capacitance.PDF
[352 KB]
Pneumatic Injection System use in finding Action of 2,3-butanedione monoxime on capacitance and electromotility of guinea-pig cochlear outer hair cells
22% Login to view WR03PL 1.PDF
[344 KB]
Pneumatic Injection System use in finding Action of 2,3-butanedione monoxime on capacitance and electromotility of guinea-pig cochlear outer hair cells
22% Login to view Regulate the Motor Output of Cochlear Outer Hair Cells.PDF
[504 KB]
Two Distinct Ca2+ - Dependent Signaling Pathways regulate the Motor Output of Cochlear Outer Hair Cells with Pneumatic Injection System
19% Login to view HS09TY Sarcoplasmic Reticulum Ca2+ Uptake and release.pdf
[1.3 MB]
Sarcoplasmic Reticulim Ca2+ Uptake and Release
17% Login to view HS03F3 Potassium channal inhibition in coronary arteries.pdf
[536 KB]
Force Displacemen Transducer, 5-hydroxytryptamine is a mediator of 4-aminopyridine induced contractions in porcine and human isolated coronary arteries
14% Login to view HS15 Myoglobin facilitates oxygen diffusion.pdf
[631 KB]
Isolated Heart Apparatus use in Myoglobin facilitating oxygen diffusion
14% Login to view HS19 Soluble Guanylyl Cyclase in Aging and Hypertension.pdf
[238 KB]
hy010000043p
14% Login to view HS02IS Evaluation of Skeletonized LITA.pdf
[228 KB]
Isolated Organ Set use in Intraoperative and Laboratory Evaluation of Skeletonized Versus Pedicled Internal Thoracic Artery
   

Back to Top



Manuals Back to Top

Displaying 1 to 1 of 1result for Chamber System Heater Controllers  

Score

Document

Description

100% Login to view Ussing Chamber Systems.pdf
[1.5 MB]
Guide to Ussing Chamber Systems
   

Back to Top

Breakthrough Products for Regenerative Medicine
2011 Regenerative Medicine Brochure
100's of Innovative products developed with leading scientists & surgeons!
  • Injection & Perfusion
  • Bioreactors
  • Biosensing
  • Total Solutions
  • Total Support


Announcing the new
PHD ULTRA™ Syringe Pumps

Click here for more information about PHD ULTRA™ Syringe Pumps and to download a brochure.

  • Patent pending mechanical design provides highest accuracy/precision & smoothest flow
  • Easy operation with advanced touch screen
  • Advanced EZ PRO™ software for PC functions without a PC.


Sign-up for a FREE Full Line Bioresearch Catalog
CLICK HERE!

  • Over 11,000 specialty products to enhance your bioresearch
  • Enhanced solutions for small animal research
  • 100's of pages of specialized information on instrumentation, applications, uses of products

 

Products on this website are for Research Use Only. Not for use in humans unless
proper investigational device regulations have been followed.


Privacy Policy   |   Terms and Conditions   
Copyright© Harvard Apparatus Ltd. - All rights reserved.
(44) 1223-423723
Website-related comments or concerns can be emailed to our webmaster.

Anesthesia Equipment Animal Handling Products Behavior Research Products Biological Measurement Products Cardiovascular Products Cell Biology Products Microincubation / Microinjectors CPK Atomic Models Delivery & Sampling Products Dialysis / Sample Prep / SPE Electroporation / Transfection Electrophysiology Products General Laboratory Products Homeothermic/Temperature Control Isolated Organ & Isolated Tissue Molecular Biology Products Neuroscience Products Non-Invasive Blood Pressure Physiology Products Respiratory Products Stereotaxic Instruments Surgical Equipment Surgical Instruments Syringe Pumps/Peristaltic Pumps Tubing & Connectors Ventilators