Welcome to Harvard Apparatus UK! Login / Register
Search

Search for these keywords
Home Catalogs Online Technical Resources My Account
Advanced Search   
Products by Category

Featured Products
Warner Cell Electrophysiology & Cell Biology Research
Hugo Sachs Elektronic Isolated Organ and Tissue Systems
BTX Electroporation and Electrofusion Products
Panlab Behavior Research Products
Hoefer Electrophoresis Products
Coulbourn Instruments
Clark Glass Products
Navicyte Ussing/Diffusion Chambers
CMA
Harvard Apparatus
 

Home Nanoliter Injector Microinjection Systems


Larger Views

 

Nanoliter Injector Microinjection Systems

The Nanoject II is the latest development in the Nanoject family of microinjectors. One of the unique features of the Nanoject II is the use of a higher torque motor than in previous models. This new motor is smoother in operation resulting in substantially reduced tip movement. A new collect configuration holds the micropipette more securely thereby reducing air infiltration and oil leakage. The two-speed fill/inject mode will allow the user to fill and inject at half speed, facilitating the use of smaller micropipettes. The handling of more viscous samples will also be improved. All of the above factors enhance the precise delivery of sample.
Search for Product in current catalog
Item Listing Full Description Specifications Journal Articles Manuals
Item# Description
690130 Nanoject II Nanoliter Injector, 115 V, 60 Hz, US Plug
690131 Nanoject II Nanoliter Injector, 230 V, 50 Hz, European Plug
690132 Nanoject II Nanoliter Injector, 230 V, 50 Hz, UK Plug
690133 Replacement Glass for Nanoliter Injector, 88.9 x 1.14 x 0.053 mm (3.5 x 0.045 x 0.021 in) (L x OD x ID), Vial of 100
690134 Replacement Glass for Nanoliter Injector, 177.8 x 1.14 x 0.053 mm (7 x 0.045 x 0.021 in) (L x OD x ID), Vial of 100
690135 Replacement Flared Glass for Nanoliter Injector, 90 mm (3.5 in), Vial of 100
690138 Replacement Wire Plunger for Nanoliter Injector
690139 Replacement Needle for Nanoliter Injector, 30 ga x 51 mm (2 in)
690140 Footswitch for Nanoliter Injector
690141 Support Base for Nanoliter Injector
690142 Universal Mounting Adapter for Nanoliter Injector

For local pricing, contact your nearest distributor.



Full Description Back to Top

• Lower volume (2.3 nl) capability
• Positive displacement technology
• 2.3 to 69.0 nl range of volumes
• Minimal vibration
• New improved high torque motor
• Membrane key pad
• Improved micropipette holder
• Two speed injection/fill rates
• Auto ‘Home’ capability

The Nanoject II is the latest development in the Nanoject family of microinjectors. One of the unique features of the Nanoject II is the use of a higher torque motor than in previous models. This new motor is smoother in operation resulting in substantially reduced tip movement. A new collect configuration holds the micropipette more securely thereby reducing air infiltration and oil leakage. The two-speed fill/inject mode will allow the user to fill and inject at half speed, facilitating the use of smaller micropipettes. The handling of more viscous samples will also be improved. All of the above factors enhance the precise delivery of sample.

Volumes for the Nanoject II range from 2.3 nl to 69 nl. Although previous models of the Nanoject series are excellent for Xenopus injections, the smaller tips and smaller injection volumes of the Nanoject II allow users to perform injections into other specimens/
applications that previously could not be performed.

Positive displacement technology and the use of precision micropipettes, eliminate the need for tedious calibration when the viscosity of the sample changes. Contaminants in the sample do not hinder or change the injection volume as with some other injectors. An optional universal mounting adapter provides easy mounting of the Nanoject II to a variety of micromanipulators and stereotaxic frames.


Specifications Back to Top

Specifications690130690131690132690133690134690135690138690139690140690141690142
CertificationsCECECE        
Power Consumption115 V, 60 Hz, US Plug230 V, 50 Hz, European Plug230 V, 50 Hz, UK Plug        
Weight Metric99.2 kg99.2 kg99.2 kg*na kg*na kg*na kg*na kg*na kg*na kg*na kg*na kg
Weight English3.5 oz3.5 oz3.5 oz*na oz*na oz*na oz*na oz*na oz*na oz*na oz*na oz
OperationAutomaticAutomaticAutomatic        
Glass PropertiesSoftening point 780°CSoftening point 780°CSoftening point 780°C        
Glass OD Metric1.14 mm1.14 mm1.14 mm1.14 mm1.14 mm*na mm*na mm*na mm*na mm*na mm*na mm
Glass OD English0.045 in0.045 in0.045 in0.045 in0.045 in*na in*na in*na in*na in*na in*na in
Glass ID Metric0.053 mm0.053 mm0.053 mm0.053 mm0.053 mm*na mm*na mm*na mm*na mm*na mm*na mm
Glass ID English0.021 in0.021 in0.021 in0.021 in0.021 in*na in*na in*na in*na in*na in*na in
Injection Speed Fast Metric46 nl/sec46 nl/sec46 nl/sec*na nl/sec*na nl/sec*na nl/sec*na nl/sec*na nl/sec*na nl/sec*na nl/sec*na nl/sec
Injection Speed Slow Metric23 nl/sec23 nl/sec23 nl/sec*na nl/sec*na nl/sec*na nl/sec*na nl/sec*na nl/sec*na nl/sec*na nl/sec*na nl/sec
Fill Speed Fast Metric46 nl/sec46 nl/sec46 nl/sec*na nl/sec*na nl/sec*na nl/sec*na nl/sec*na nl/sec*na nl/sec*na nl/sec*na nl/sec
Fill Speed Slow Metric23 nl/sec23 nl/sec23 nl/sec*na nl/sec*na nl/sec*na nl/sec*na nl/sec*na nl/sec*na nl/sec*na nl/sec*na nl/sec
Empty Speed Metric92 nl/sec92 nl/sec92 nl/sec*na nl/sec*na nl/sec*na nl/sec*na nl/sec*na nl/sec*na nl/sec*na nl/sec*na nl/sec
Volume Range Metric2.3 to 69.0 nl2.3 to 69.0 nl2.3 to 69.0 nl*na nl*na nl*na nl*na nl*na nl*na nl*na nl*na nl
Change VolumeDip switches #1 to #4Dip switches #1 to #4Dip switches #1 to #4        
Change Inject SpeedDip switch #5Dip switch #5Dip switch #5        
Glass Length Metric*na mm*na mm*na mm88.9 mm177.8 mm90 mm*na mm*na mm*na mm*na mm*na mm
Glass Length English*na in*na in*na in3.5 in7 in3.5 in*na in*na in*na in*na in*na in
Diameter Metric*na mm*na mm*na mm*na mm*na mm*na mm*na mm51 mm*na mm*na mm*na mm
Diameter English*na in*na in*na in*na in*na in*na in*na in2 in*na in*na in*na in
Gauge       30   

Back to Top



Journal Articles Back to Top

Displaying 11 to 20 of 30results for Nanoliter Injector Microinjection Systems   Page 1  2  3 

Score

Document

Description

32% Login to view Intracellular Calcium Oscillations Signal Apoptosis.pdf
[826 KB]
PicoInjector use in Intracellular Calcium Oscillations Signal Apoptosis
32% Login to view Slow Axonal Transport of Neurofilament Protein.PDF
[1.5 MB]
PLI-100 use in finding Slow Axonal Transport of Neurofilament Protein in Cultured Neurons
32% Login to view PI15 plihorse.pdf
[278 KB]
Patterns of Intracellular Calcium Oscillations in Horse Oocytes Fertilized by Intracytoplasmic Sperm Injection
27% Login to view Rapid Intermittent Movement of Axonal Neurofilaments.PDF
[743 KB]
Pressure Injector use in finding Rapid Intermittent Movement of Axonal Neurofilaments Observed by Fluorescene Photobleaching
26% Login to view PI10 PLI 100.pdf
[364 KB]
Ca2+ Independent Protein Kinase C Apl II Mediates the Serotonin-Induced Facilitation at Depressed Aplysia Sensorimotor Synapses
26% Login to view Isoforms of the Inositol 1,4,5-Trisphosphate Receptor Are Expressed in Bovine Oocytes and Ovaries.pdf
[309 KB]
Isoforms of the Inositol 1,4,5-Triphosphate Receptor Expressed in Bovine Oocytes and Ovaries
25% Login to view PI01PL 1.PDF
[734 KB]
Pressure Injector use in finding Rapid Intermittent Movement of Axonal Neurofilaments Observed by Fluorescene Photobleaching
25% Login to view HB01 Assessment of Tissue Oxygen Tension.pdf
[270 KB]
Homeothermic Blanket Assessment of tissue oxygen tension
25% Login to view HB03 Leukotriene B4 Promotes Reactive Oxidant Generation and Leukocyte Adherence During Acute Hypoxia.pdf
[198 KB]
Homeothermic Blanket Leukotrience B4 promotes reactive oxidant generation and leukocyte adherence during acute hypoxia
25% Login to view HB02 Regulation of Transcription by a Protein Methyltransferase.pdf
[264 KB]
   

Back to Top



Manuals Back to Top

Displaying 1 to 2 of 2results for Nanoliter Injector Microinjection Systems  

Score

Document

Description

100% Login to view PicoInjector PLI90.pdf
[110 KB]
Model PLI-90 Pico Injector Manual
88% Login to view PicoInjector PLI100.pdf
[949 KB]
Model PLI-100 Pico Injector Manual
   

Back to Top

Breakthrough Products for Regenerative Medicine
2011 Regenerative Medicine Brochure
100's of Innovative products developed with leading scientists & surgeons!
  • Injection & Perfusion
  • Bioreactors
  • Biosensing
  • Total Solutions
  • Total Support


Announcing the new
PHD ULTRA™ Syringe Pumps

Click here for more information about PHD ULTRA™ Syringe Pumps and to download a brochure.

  • Patent pending mechanical design provides highest accuracy/precision & smoothest flow
  • Easy operation with advanced touch screen
  • Advanced EZ PRO™ software for PC functions without a PC.


Sign-up for a FREE Full Line Bioresearch Catalog
CLICK HERE!

  • Over 11,000 specialty products to enhance your bioresearch
  • Enhanced solutions for small animal research
  • 100's of pages of specialized information on instrumentation, applications, uses of products

 

Products on this website are for Research Use Only. Not for use in humans unless
proper investigational device regulations have been followed.


Privacy Policy   |   Terms and Conditions   
Copyright© Harvard Apparatus Ltd. - All rights reserved.
(44) 1223-423723
Website-related comments or concerns can be emailed to our webmaster.

Anesthesia Equipment Animal Handling Products Behavior Research Products Biological Measurement Products Cardiovascular Products Cell Biology Products Microincubation / Microinjectors CPK® Atomic Models Delivery & Sampling Products Dialysis / Sample Prep / SPE Electroporation / Transfection Electrophysiology Products General Laboratory Products Homeothermic/Temperature Control Isolated Organ & Isolated Tissue Molecular Biology Products Neuroscience Products Non-Invasive Blood Pressure Physiology Products Respiratory Products Stereotaxic Instruments Surgical Equipment Surgical Instruments Syringe Pumps/Peristaltic Pumps Tubing & Connectors Ventilators