Welcome to Harvard Apparatus UK! Login / Register
Search

Search for these keywords
Home Catalogs Online Technical Resources My Account
Advanced Search   
Products by Category

Featured Products
Warner Cell Electrophysiology & Cell Biology Research
Hugo Sachs Elektronic Isolated Organ and Tissue Systems
BTX Electroporation and Electrofusion Products
Panlab Behavior Research Products
Hoefer Electrophoresis Products
Coulbourn Instruments
Clark Glass Products
Navicyte Ussing/Diffusion Chambers
CMA
Harvard Apparatus
 

Home Syringe Pumps/Peristaltic Pumps Centrifugal Pump


Larger Views

 

Centrifugal Pump

The centrifugal pump is specifically designed for pumping blood and/or erythrocyte suspension solutions in the physiological or pharmacological laboratory. It consists of the pump drive BVP-ZX and a centrifugal pump head which can be replaced without tools. Pump heads are hermetically sealed. The coupling to the motor of the pump drive is carried out via magnetic force; there is no axle.
Search for Product in current catalog
Item Listing Full Description Specifications Journal Articles Manuals
Item# Description
732470 BVP-ZX Centrifugal Pump, 230 VAC
732963 BVP-ZX Centrifugal Pump, 115 VAC

For local pricing, contact your nearest distributor.



Full Description Back to Top

• Low hemolysis
• Flow rates up to 16 L/min
• No or only low pulsation
• Smooth run, producing only low noise
• Pump heads interchangeable without tool
• Speed setting by a digital switch in 0.1% steps
• “Max Speed” button for quick fill or ventilate
• Robust construction for long life time
• Analoge interface for remote control

The centrifugal pump is specifically designed for pumping blood and/or erythrocyte suspension solutions in the physiological or pharmacological laboratory. It consists of the pump drive BVP-ZX and a centrifugal pump head which can be replaced without tools. Pump heads are hermetically sealed. The coupling to the motor of the pump drive is carried out via magnetic force; there is no axle.
The pump speed is set using a 3-digit potentiometer switch (000 to 999) or via an analog interface.
The drive is very robust and suitable for continuous speed selection operation.
The pump drive and pump heads must be purchased separately. The pump heads are interchangeable and do not require tools to change.


Specifications Back to Top

Specifications732470732963
ModelBVP-ZXBVP-ZX
Speed3 to 3000 rpm, adjustable in 0.1% steps3 to 3000 rpm, adjustable in 0.1% steps
Mains Connection20 (50/60 Hz) 115 V (50/60 Hz)20 (50/60 Hz) 115 V (50/60 Hz)
Power Consumption120 W maximum120 W maximum
Analog InterfaceSpeed Controls 0-5 V or 0-10 V or 0-20 mA or 4-20 mA, start/stop (TTL contacts)Speed Controls 0-5 V or 0-10 V or 0-20 mA or 4-20 mA, start/stop (TTL contacts)
Operating Conditions0 - 40 C (normal environment conditions)0 - 40 C (normal environment conditions)
Dimensions (H x W x D) Metric260 x 155 x 260 mm260 x 155 x 260 mm
Dimensions (H x W x D) English10.2 x 6.1 x 10.2 in10.2 x 6.1 x 10.2 in
Weight (without pump head) (kg)7 kg7 kg
Weight (without pump head) (lbs)15.4 lbs15.4 lbs
Protection RatingIP30IP30

Back to Top



Journal Articles Back to Top

Displaying 71 to 80 of 89results for Centrifugal Pump   Page 1  2  3  4  5  6  7  8  9 

Score

Document

Description

14% Login to view PP28MO 1.PDF
[424 KB]
Electrospray ionization tandem mass spectrometric study of salt cluster ions with use of Model 11 syringe pump
14% Login to view PP05 Syringe MS Pump.pdf
[201 KB]
Electrospray Ionization Mass Spectrometric Anlyses of Phospholipids from Rat and Human Pancreatic Islets and Subcellular Membranes with us of Harvard Syringe Pump
13% Login to view PP73 Syringe Pump22 infuse.pdf
[646 KB]
Harvard 22 Syringe Pump use in finding set-point model with oscillatory behavior predicts the time course of 8-OH-DPAT-induced hypothermia
13% Login to view PP104 eqpump.pdf
[373 KB]
Syringe Pump use in finding the Binding of the Circumsporozoite Protein to Cell Surface Heparan Sulfate Proteoglycans is Required for Plasmodium Sporozite Attachment to Target Cells
13% Login to view PP61 Temporal Gradients in Shear, but Not Spatial Gradients, Stimulate Endothelial Cell Proliferation.pdf
[514 KB]
Temporal Gradients in Shear, but Not Spatial Gradients, Stimulate Endothelial Cell Proliferation
13% Login to view PP22 DNA-Interacting Proteins in the Spermiogenesis of the Mollusc Murex Brandaris.pdf
[137 KB]
Synthesis, crystal structure and electrospray ionisation mass spectrometry of a novel one-dimensional cyano-bridged Ni(ii)-Au(i) polymer
13% Login to view PP65 Formation and Decomposition of Water Clusters as Observed in a Triple Quadrupole Mass Spectrometer.pdf
[388 KB]
PII: S1044-0305(98)00044-0
13% Login to view PP51 Inhibition of Poly(ADP-Ribose) Polymerase.pdf
[527 KB]
pq079903900p
13% Login to view PP58 Endothelium-Derived Nitric Oxide Regulates Arterial Elasticity in Human Arteries In Vivo.pdf
[76 KB]
AASANAP289
13% Login to view PP42 Branched-Chain Keto Acid Catabolism via the Gene Products of the bkd Operon in Enterococcus faecalis.pdf
[407 KB]
Branched-Chain Keto Acid Catabolism via the Gene Products of the bkd Operon in Enterococcus faecalis
   

Back to Top



Manuals Back to Top

Displaying 1 to 7 of 7results for Centrifugal Pump  

Score

Document

Description

100% Login to view Harvard Peristaltic Pump Brochure.pdf
[1.6 MB]
Harvard Peristaltic Pump Brochure
96% Login to view 11 Elite Syringe Pump User Manual.pdf
[3.2 MB]
Pump 11 Elite User Manual
88% Login to view Nanoleader Pump Series NLS110P Pressure Pump Manual.pdf
[2.2 MB]
705000 NLS110P Pump Manual
87% Login to view Pump Selection Guide.pdf
[263 KB]
DC1_A_Pumps.qxd
64% Login to view CMA Microdialysis Model 402 Syringe Pump Datasheet.pdf
[1.4 MB]
Dual Syringe Pump by CMA - Datasheet
50% Login to view CMA Microdialysis Model 400 Syringe Pump Datasheet.pdf
[1.4 MB]
Not Available
50% Login to view CMA Microdialysis Model 4004 Syringe Pump Datasheet.pdf
[1.2 MB]
Not Available
   

Back to Top

Breakthrough Products for Regenerative Medicine
2011 Regenerative Medicine Brochure
100's of Innovative products developed with leading scientists & surgeons!
  • Injection & Perfusion
  • Bioreactors
  • Biosensing
  • Total Solutions
  • Total Support


Announcing the new
PHD ULTRA™ Syringe Pumps

Click here for more information about PHD ULTRA™ Syringe Pumps and to download a brochure.

  • Patent pending mechanical design provides highest accuracy/precision & smoothest flow
  • Easy operation with advanced touch screen
  • Advanced EZ PRO™ software for PC functions without a PC.


Sign-up for a FREE Full Line Bioresearch Catalog
CLICK HERE!

  • Over 11,000 specialty products to enhance your bioresearch
  • Enhanced solutions for small animal research
  • 100's of pages of specialized information on instrumentation, applications, uses of products

 

Products on this website are for Research Use Only. Not for use in humans unless
proper investigational device regulations have been followed.


Privacy Policy   |   Terms and Conditions   
Copyright© Harvard Apparatus Ltd. - All rights reserved.
(44) 1223-423723
Website-related comments or concerns can be emailed to our webmaster.

Anesthesia Equipment Animal Handling Products Behavior Research Products Biological Measurement Products Cardiovascular Products Cell Biology Products Microincubation / Microinjectors CPK® Atomic Models Delivery & Sampling Products Dialysis / Sample Prep / SPE Electroporation / Transfection Electrophysiology Products General Laboratory Products Homeothermic/Temperature Control Isolated Organ & Isolated Tissue Molecular Biology Products Neuroscience Products Non-Invasive Blood Pressure Physiology Products Respiratory Products Stereotaxic Instruments Surgical Equipment Surgical Instruments Syringe Pumps/Peristaltic Pumps Tubing & Connectors Ventilators