Welcome to Harvard Apparatus UK! Login / Register
Search

Search for these keywords
Home Catalogs Online Technical Resources My Account
Advanced Search   
Products by Category

Featured Products
Warner Cell Electrophysiology & Cell Biology Research
Hugo Sachs Elektronic Isolated Organ and Tissue Systems
BTX Electroporation and Electrofusion Products
Panlab Behavior Research Products
Hoefer Electrophoresis Products
Coulbourn Instruments
Clark Glass Products
Navicyte Ussing/Diffusion Chambers
CMA
Harvard Apparatus
 

Home Syringe Pumps/Peristaltic Pumps Shuttle Pump


Larger Views

 

Shuttle Pump

This Shuttle Pump is based on a patented dual-channel shuttle pump mechanism that can deliver flow rates up to 50 ml/min, but is small and incredibly power efficient. This unique pump was designed for cell culture experiments conducted on the Space Shuttle, where weight and power consumption are significant constraints.
Search for Product in current catalog
Item Listing Full Description Specifications Journal Articles Manuals
Item# Description
610128 Harvard Apparatus Shuttle Pump, 120 VAC
720011 Harvard Apparatus Shuttle Pump, 220 VAC

For local pricing, contact your nearest distributor.



Full Description Back to Top

• Battery powered
• Perfect for cell culture work
• Fits in palm of your hand
• Flow rates up to 50 ml/minute
• Extremely energy efficient
• Gentle pulsatile flow
• Extended tubing life

This Shuttle Pump is based on a patented dual-channel shuttle pump mechanism that can deliver flow rates up to 50 ml/min, but is small and incredibly power efficient. This unique pump was designed for cell culture experiments conducted on the Space Shuttle, where weight and power consumption are significant constraints.
Efficient Design
This fluid pump uses two easily removable pumping chambers on either side of an oscillating shuttle. The balanced tube arrangement, high-efficiency motor, and 4 passive check valves result in a pump that is far more efficient than a typical peristaltic pump: 13 times higher flow rates with 60% lower weight and 90% lower power consumption.
Gentle Pumping Action
The oscillating shuttle does not squeeze the tubes to occlusion, making this device ideal for pumping cell suspensions and blood. Fluid can free flow through the pump in the forward direction, simplifying filling and purging, but limiting applications to those where outflow pressure is greater than inflow pressure. Single or dual channel operation. Join the two tubes to form a single input and output and thereby generate twice the flow rate with less pulsation.
Built-In Control Circuitry
Adjust the motor speed over a 20:1 range using the knob on the top of the pump.
OEM
The pump mechanism is also available for OEM applications.
Please call Harvard Apparatus for details


Specifications Back to Top

Specifications610128720011
OD (mm)3.4 mm3.4 mm
OD (inch)0.135 in0.135 in
Dimensions (H x W x D) Metric3.3 x 11.4 x 7.2 cm3.3 x 11.4 x 7.2 cm
Dimensions (H x W x D) English1.3 x 4.5 x 2.8 in1.3 x 4.5 x 2.8 in
Flow Rate Both Tubes Combined2.5 to 50 ml/min (no back pressure)2.5 to 50 ml/min (no back pressure)
Flow Rate Single Tube1.25 to 25 ml/min (no back pressure)1.25 to 25 ml/min (no back pressure)
Flow WaveformPulsatilePulsatile
Pumping Chambers2 per pump2 per pump
Pulses per Minute~ 45 at 6 ml/min (single channel)~ 45 at 6 ml/min (single channel)
Developed Pressure9 PSI (flow = 0), maximum9 PSI (flow = 0), maximum
Tubing Life> 3 months> 3 months
Power Source Provided9 V battery and AC adapter9 V battery and AC adapter
Battery Life50 hrs under continuous operation, 9 V lithium50 hrs under continuous operation, 9 V lithium

Back to Top



Journal Articles Back to Top

Displaying 61 to 70 of 90results for Shuttle Pump   Page 1  2  3  4  5  6  7  8  9 

Score

Document

Description

16% Login to view PP02 micdrvpmp.pdf
[212 KB]
Microdrive Pump use in finding Intake of High-Fat Food is Selectively Enhanced by Mu Opioid Receptor Stimulation within the Nucleus Accumbens
16% Login to view PP07 Syringe Pump.pdf
[305 KB]
Syringe Pump use in Mapping the Glycoprotein Ib-binding Site in the von Willebrand Factor A1 Domain
16% Login to view PP116 phd 2.pdf
[90 KB]
PHD 2000 Programmable Syringe Pump used in Analysis of Biomolecular Interactions Using a Miniaturized Surface Plasmon Resonance Sensor
16% Login to view PP111 pmp.pdf
[395 KB]
Volume controlled pump use in finding Development and Response Timing and Direction Selectivity in Cat Visual Thalamus and Cortex
16% Login to view PP67 Muscimol Inactivation of the Dorsal Hippocampus Impairs Contextual Retrieval of Fear Memory.pdf
[296 KB]
Infusion Pump use in finding Muscimol Inactivation of the Dorsal Hippocampus Impairs Contextual Retrieval of Fear Memory
16% Login to view PP01 pumpms.pdf
[215 KB]
Microdrive Pump use in finding Intake of High-Fat Food is Selectively Enhanced by Mu Opioid Receptor Stimulation within the Nucleus Accumbens
16% Login to view PP07 Mapping the Glycoprotein Ib-Binding Site in the Von Willebrand Factor A1 Domain.pdf
[312 KB]
Syringe Pump use in Mapping the Glycoprotein Ib-binding Site in the von Willebrand Factor A1 Domain
16% Login to view PP04 The Analysis of Jojoba Oil by LC-Coordination Ion Spray-MS (LC-CIS-MS).pdf
[206 KB]
Electrospray Ionization Mass Spectrometric Anlyses of Phospholipids from Rat and Human Pancreatic Islets and Subcellular Membranes with us of Harvard Syringe Pump
15% Login to view PP108 mri22.pdf
[116 KB]
Infusion Pump use in finding Effects of Chemotherapy by 1,3-Bis(2-chloroethyl)-1-nitrosourea
15% Login to view PP103 bupmp.pdf
[152 KB]
Syringe Pump use in finding Polynuclear Complexes of Copper and the 2-3(5)-Pyrazolyl)-6-methylpyridine Ligand
   

Back to Top



Manuals Back to Top

Displaying 1 to 4 of 4results for Shuttle Pump  

Score

Document

Description

100% Login to view Pump Selection Guide.pdf
[263 KB]
DC1_A_Pumps.qxd
58% Login to view Harvard Peristaltic Pump Brochure.pdf
[1.6 MB]
Harvard Peristaltic Pump Brochure
56% Login to view 11 Elite Syringe Pump User Manual.pdf
[3.2 MB]
Pump 11 Elite User Manual
51% Login to view Nanoleader Pump Series NLS110P Pressure Pump Manual.pdf
[2.2 MB]
705000 NLS110P Pump Manual
   

Back to Top

Breakthrough Products for Regenerative Medicine
2011 Regenerative Medicine Brochure
100's of Innovative products developed with leading scientists & surgeons!
  • Injection & Perfusion
  • Bioreactors
  • Biosensing
  • Total Solutions
  • Total Support


Announcing the new
PHD ULTRA™ Syringe Pumps

Click here for more information about PHD ULTRA™ Syringe Pumps and to download a brochure.

  • Patent pending mechanical design provides highest accuracy/precision & smoothest flow
  • Easy operation with advanced touch screen
  • Advanced EZ PRO™ software for PC functions without a PC.


Sign-up for a FREE Full Line Bioresearch Catalog
CLICK HERE!

  • Over 11,000 specialty products to enhance your bioresearch
  • Enhanced solutions for small animal research
  • 100's of pages of specialized information on instrumentation, applications, uses of products

 

Products on this website are for Research Use Only. Not for use in humans unless
proper investigational device regulations have been followed.


Privacy Policy   |   Terms and Conditions   
Copyright© Harvard Apparatus Ltd. - All rights reserved.
(44) 1223-423723
Website-related comments or concerns can be emailed to our webmaster.

Anesthesia Equipment Animal Handling Products Behavior Research Products Biological Measurement Products Cardiovascular Products Cell Biology Products Microincubation / Microinjectors CPK® Atomic Models Delivery & Sampling Products Dialysis / Sample Prep / SPE Electroporation / Transfection Electrophysiology Products General Laboratory Products Homeothermic/Temperature Control Isolated Organ & Isolated Tissue Molecular Biology Products Neuroscience Products Non-Invasive Blood Pressure Physiology Products Respiratory Products Stereotaxic Instruments Surgical Equipment Surgical Instruments Syringe Pumps/Peristaltic Pumps Tubing & Connectors Ventilators