Home Isolated Organ & Isolated Tissue HSE Effluate Monitoring Systems (pH, pO2, pCO2) Universal Flow-thru Fluid Monitoring System (pO2, pCO2, pH)


Larger Views

 

Universal Flow-thru Fluid Monitoring System (pO2, pCO2, pH)

For studies involving isolated or in situ perfused organs (heart, lung, liver, kidney) it is often important to continuously monitor pO2, pCO2 and/or pH of the perfusate. Which parameter is measured depends on the organ used and on the type of experiment conducted.
Search for Product in current catalog
Item Listing Full Description Journal Articles Manuals
Item# Description
739924 Universal Perfusion Solution Monitor (ZABS)

For local pricing, contact your nearest distributor.



Full Description Back to Top

• Compact arrangement, ready to use
• Monitors key parameters in perfusate:
– pO2
– pCO2
– pH
• Flow-through sensors

For studies involving isolated or in situ perfused organs (heart, lung, liver, kidney) it is often important to continuously monitor pO2, pCO2 and/or pH of the perfusate. Which parameter is measured depends on the organ used and on the type of experiment conducted.
The universal perfusion solution monitor permits precise continuous or discontinuous measurement in liquid media of these three key parameters pO2, pCO2 and pH. The electrodes are all side stream flow-through electrodes and require a pulsation-free roller pump to deliver constant flow of perfusate through the electrode at flow rates in the range from 0.5 to 2 ml/min. The solution is split in parallel and pulled through each of the electrodes simultaneously. Therefore the total minute volume is a function of the flow rate and the number of electrodes used.
The pH sensor requires an external reference electrode (both the pO2 and pCO2 contain internal reference electrodes). For pH measurements one of two external reference electrodes are available; either the solid state leak free reference system or a KCl bridge (wet cell) reference system. The solid state leak free reference system is used whenever the perfusate must be recirculated or is required for further analysis. For applications using perfusate containing proteins like albumin it may be necessary to use the KCl bridge reference system for long term signal stability. Because of the high impedance of these sensors, screening or shielding of the measuring circuit is required to guard against electrostatic discharges and other electrical disturbances. The shielding cases also provide a convenient point of attachment to the multi-electrode mounting plate. The electrical signal produced by the electrodes is amplified by one of three PLUGSYS modules OPPM, pHMM or EMM for the O2, pH and CO2 electrodes respectively.


Journal Articles Back to Top

Displaying 1 to 10 of 13results for Universal Flow-thru Fluid Monitoring System (pO2, pCO2, pH)   Page 1  2 

Score

Document

Description

100% Login to view flow thru dial.pdf
[387 KB]
A Novel Approach for the Extraction and Concentration of Compounds in Biological Fluids via On-Line Dialysis and Enrichment
32% Login to view VT43.pdf
[264 KB]
Effects of hyper- and hypoventilation on gastric and sublingual PCO2
21% Login to view Noninvasive measurement of the pH of the endoplasmic reticulum.PDF
[372 KB]
Noninvasive measurement of the pH of the endoplasmic reticulum at rest and during calcium release
19% Login to view OT19.pdf
[70 KB]
PO2 AND CALCULATED OXYGEN SATURATED
17% Login to view PP45 Syringe Pump.pdf
[764 KB]
Precision Alignment Packaging For Microsystems with Multiple Fluid Connections
16% Login to view VT24 Intramucosal-arterial Pco2 gap fails to reflect intestinal dysoxia in hypoxic hypoxia.pdf
[156 KB]
MiniVent use in finding Evidence for Synergy Between Adrenergic and Nonadrenergic Mechanisms in Central Blood Pressure Regulation
15% Login to view PP94 Aquaporin Deletion in Mice Reduces Intraocular Pressure and Aqueous Fluid Production.pdf
[722 KB]
Aquaporin Deletion in Mice Reduces Intraocular Pressure and Aqueous Fluid Production
15% Login to view PP45 Precision Alignment Packaging for Microsystems with Multiple Fluid Connections.pdf
[301 KB]
Union of capillary high-performance liquid chromatography
13% Login to view VT18 PDMI2 Microincubator.pdf
[456 KB]
PDMI-2 Microincubator use in Airway surface liquid pH in well-differentiated airway epithelial cell cultures and mouse trachea
13% Login to view VT24 Pump Ventilator.pdf
[90 KB]
Intramucosal-arterial Pco2 gap fails to reflect intestinal dysoxia in hypoxic hypoxia
   

Back to Top



Manuals Back to Top

Displaying 1 to 1 of 1result for Universal Flow-thru Fluid Monitoring System (pO2, pCO2, pH)  

Score

Document

Description

100% Login to view Flow-Thru DIALYZER.pdf
[102 KB]
Flow-Thru DIALYZER
   

Back to Top

Breakthrough Products for Regenerative Medicine
2011 Regenerative Medicine Brochure
100's of Innovative products developed with leading scientists & surgeons!
  • Injection & Perfusion
  • Bioreactors
  • Biosensing
  • Total Solutions
  • Total Support


Announcing the new
PHD ULTRA™ Syringe Pumps

Click here for more information about PHD ULTRA™ Syringe Pumps and to download a brochure.

  • Patent pending mechanical design provides highest accuracy/precision & smoothest flow
  • Easy operation with advanced touch screen
  • Advanced EZ PRO™ software for PC functions without a PC.


Sign-up for a FREE Full Line Bioresearch Catalog
CLICK HERE!

  • Over 11,000 specialty products to enhance your bioresearch
  • Enhanced solutions for small animal research
  • 100's of pages of specialized information on instrumentation, applications, uses of products

 

Products on this website are for Research Use Only. Not for use in humans unless
proper investigational device regulations have been followed.


Privacy Policy   |   Terms and Conditions   
Copyright© Harvard Apparatus Ltd. - All rights reserved.
(44) 1223-423723
Website-related comments or concerns can be emailed to our webmaster.

Anesthesia Equipment Animal Handling Products Behavior Research Products Biological Measurement Products Cardiovascular Products Cell Biology Products Microincubation / Microinjectors CPK® Atomic Models Delivery & Sampling Products Dialysis / Sample Prep / SPE Electroporation / Transfection Electrophysiology Products General Laboratory Products Homeothermic/Temperature Control Isolated Organ & Isolated Tissue Molecular Biology Products Neuroscience Products Non-Invasive Blood Pressure Physiology Products Respiratory Products Stereotaxic Instruments Surgical Equipment Surgical Instruments Syringe Pumps/Peristaltic Pumps Tubing & Connectors Ventilators