Welcome to Harvard Apparatus UK! Login / Register
Search

Search for these keywords
Home Catalogs Online Technical Resources My Account
Advanced Search   
Products by Category

Featured Products
Warner Cell Electrophysiology & Cell Biology Research
Hugo Sachs Elektronic Isolated Organ and Tissue Systems
BTX Electroporation and Electrofusion Products
Panlab Behavior Research Products
Hoefer Electrophoresis Products
Coulbourn Instruments
Clark Glass Products
Navicyte Ussing/Diffusion Chambers
CMA
Harvard Apparatus
 

Home Microincubation / Microinjectors Microinjection Systems Pressure Injection Systems


Larger Views

 

Pressure Injection Systems

The PM-4 and PM-8 programmable 4 and 8-Channel Pressure Injector systems are designed for one to eight channel intracellular injection and extracellular perfusion. These microinjection and perfusion engines are especially designed for pharmacological drug testing, molecular biological DNA, RNA transferring, intracytoplasmic sperm injection and cell electrophysiological applications.
Search for Product in current catalog
Item Listing Full Description Specifications Journal Articles Manuals
Item# Description
690152 Model PM4 4-Channel Pressure Injection System
690153 Model PM8 8-Channel Pressure Injection System
690164 PP-4 Pulled 4-Barrel Pipette
690163 PP-7 Pulled 7-Barrel Pipette

For local pricing, contact your nearest distributor.



Full Description Back to Top

• Multiple function system for micro-injection and perfusion
• Up to 8 injection/perfusion outputs, one hold cell output and one synchronized drain out channel
• Programmable timers, counters and step sequences which can be stored for reuse
• Manual control or automatic sequential step cycle operation
• Front panel display for pressures and programming information

The PM-4 and PM-8 programmable 4 and 8-Channel Pressure Injector systems are designed for one to eight channel intracellular injection and extracellular perfusion. These microinjection and perfusion engines are especially designed for pharmacological drug testing, molecular biological DNA, RNA transferring, intracytoplasmic sperm injection and cell electrophysiological applications.

Combining an advanced micro-controller with precision pneumatic components, these systems can simultaneously control up to eight injection micropipettes or eight perfusion vials and one cell holding pipette and one drain pipette. The four (PM-4) or eight (PM-8) injection/perfusion output ports can be controlled separately or combined together to perform actions such as injection, capillary action balancing, suction or clear up. The cell holding output port can produce an adjusted gentle suction to hold a cell, eject a pressure to push a cell, or completely clear the holding pipette. Another drain output port can simultaneously produce an adjusted suction to drain and clear out liquid before the next channel micro-perfusion. The PM-4/8 can deliver different quantity agents and drugs from picoliters to continuous perfusion. All output pressures and vacuums can be regulated and can be displayed real-time on the front panel display. Previous pressure readings can also be recovered on the display for setting comparison.

Besides programmable timers and counters, there are 16 programmable and savable injection/perfusion sequences with 32 programmable steps in each sequence. Each sequence can be repeated continuously or triggered manually. The interval time between steps can be programmed for automatic sequential cycle or manual trigger. There are two foot switch connectors for sequential step trigger and injection trigger. A digital remote port can be connected to an optional remote key pad or be controlled by a computer. With exceptional versatility and extremely precise control, either the PM-4 or 8 is an ideal multi-channel injection/perfusion engine. Below are the components supplied with each of the Pressure Injection Systems.

Pressure Injection System 69-0152 or 69-0153
Cat. No. Product
69-0154 IP1 Input Tubing with Connector Qty: 1 or 1
69-0156 OP2 Output Tubing with Connector Only Qty: 6 or 10
69-0157 FSW Foot Switch Qty: 1
69-0164 PP-4 Pulled 4-Barrel Pipette Qty: 1 or 0
69-0166 HOLD4 Holder for 4-Barrel Pipette Qty: 1 or 0
69-0163 PP-7 Pulled 7-Barrel Pipette Qty: 1 or 0
69-0167 HOLD7 Holder for 7-Barrel Pipette Qty: 1 or 0
- Power Cord Qty: 1 or 1
- User’s Manual Qty: 1 or 1


Specifications Back to Top

Specifications690152690153690164690163
ModelPM4PM8PP-4PP-7
CertificationsCECE  
Output ChannelsFour (PM-4) or eight (PM-8) injection / perfusion outputs, one synchronized drain out and one cell hold channelFour (PM-4) or eight (PM-8) injection / perfusion outputs, one synchronized drain out and one cell hold channel  
Input Gas Pressure English30 to 100 p.s.i.30 to 100 p.s.i.*na p.s.i.*na p.s.i.
Clearing Pressure English30 to 100 p.s.i.30 to 100 p.s.i.*na p.s.i.*na p.s.i.
Clear Hold Pressure English0 to 3 p.s.i. (regulated)0 to 3 p.s.i. (regulated)*na p.s.i. (regulated)*na p.s.i. (regulated)
Injection Pressure English0.05 to 60 p.s.i. (regulated)0.05 to 60 p.s.i. (regulated)*na p.s.i. (regulated)*na p.s.i. (regulated)
Balance Pressure English0.05 to 10 p.s.i. (regulated)0.05 to 10 p.s.i. (regulated)*na p.s.i. (regulated)*na p.s.i. (regulated)
Fill Vacuum English0 to 24 inHg (regulated)0 to 24 inHg (regulated)*na inHg (regulated)*na inHg (regulated)
Hold Vacuum Metric0 to 30 in of water (regulated)0 to 30 in of water (regulated)*na in of water (regulated)*na in of water (regulated)
Drain Vacuum0 to 30 in of water (regulated)0 to 30 in of water (regulated)*na in of water (regulated)*na in of water (regulated)
Repeatability±0.02 p.s.i. p.s.i.±0.02 p.s.i. p.s.i.*na p.s.i.*na p.s.i.
Display Accuracy±0.05 p.s.i. for pressure, ±0.2 in for vacuum (< 2 in H2O)±0.05 p.s.i. for pressure, ±0.2 in for vacuum (< 2 in H2O)  
Timer Setting Range10 msec to 327.67 sec (10 msec resolution for whole range)10 msec to 327.67 sec (10 msec resolution for whole range)  
Counter Setting Range1 to 2551 to 255  
Savable Sequences16 sequences16 sequences  
Programmable Steps32 steps for each sequence32 steps for each sequence  
Remote Control PortsDB9 connector for remote key pad, foot switch jack and BNC for negative TTL trigger, jack connector for injection foot switchDB9 connector for remote key pad, foot switch jack and BNC for negative TTL trigger, jack connector for injection foot switch  
Signal Output PortsEight BNCs for injection signal on output port 1 to 4Eight BNCs for injection signal on output port 1 to 4  
Power Consumption100, 120 or 220 VAC, 35 W100, 120 or 220 VAC, 35 W  

Back to Top



Journal Articles Back to Top

Displaying 1 to 10 of 28results for Pressure Injection Systems   Page 1  2  3 

Score

Document

Description

100% Login to view HS08 pressure transducer.pdf
[46 KB]
Pressure Transducer use in finding blood pressure and heart rate spectral changes
32% Login to view PI15 plihorse.pdf
[278 KB]
Patterns of Intracellular Calcium Oscillations in Horse Oocytes Fertilized by Intracytoplasmic Sperm Injection
30% Login to view WR04PL 1.PDF
[495 KB]
Two Distinct Ca2+ - Dependent Signaling Pathways regulate the Motor Output of Cochlear Outer Hair Cells with Pneumatic Injection System
29% Login to view HB06 Neuroprotein and Neurotoxicity Studies in Rats.pdf
[523 KB]
Intracellular Response Properties of Units in the Dorsal Cochlear Nucleus of Unanesthetized Decerebrate Gerbil
29% Login to view HB03 Leukotriene B4 Promotes Reactive Oxidant Generation and Leukocyte Adherence During Acute Hypoxia.pdf
[198 KB]
Homeothermic Blanket Leukotrience B4 promotes reactive oxidant generation and leukocyte adherence during acute hypoxia
29% Login to view HB09 Two-Photon Imaging of Capillary Blood Flow in Olfactory Bulb Glomeruli.pdf
[989 KB]
Two-photon imaging of capillary blood flow in olfactory bulb golmeruli
29% Login to view HB04 Intracellularly Labeled Fusiform Cells in Dorsal Cochlear Nucleus of hte Gerbil.pdf
[475 KB]
Homeothermic Blanket Intracellularly Labeled Fusiform Cells in Dorsal Cochlear Nucleus of the Gerbil
28% Login to view PP69 PHD 2000 Syringe Pump.pdf
[598 KB]
Passive mixing in a three-dimensional serpentine microchannel - Microelectromechanical Systems, Journal of
28% Login to view BOR Papers in Press. Published on December 3, 2003.pdf
[289 KB]
Patterns of Intracellular Calcium Oscillations in Horse Oocytes Fertilized by Intracytoplasmic Sperm Injection
26% Login to view Action of 2,3-butanedione monoxime on capacitance.PDF
[352 KB]
Pneumatic Injection System use in finding Action of 2,3-butanedione monoxime on capacitance and electromotility of guinea-pig cochlear outer hair cells
   

Back to Top



Manuals Back to Top

Displaying 1 to 1 of 1result for Pressure Injection Systems  

Score

Document

Description

100% Login to view Perfusion Tissue Systems Guide.pdf
[105 KB]
New BS4_K_Isolated Organ.qxd
   

Back to Top

Breakthrough Products for Regenerative Medicine
2011 Regenerative Medicine Brochure
100's of Innovative products developed with leading scientists & surgeons!
  • Injection & Perfusion
  • Bioreactors
  • Biosensing
  • Total Solutions
  • Total Support


Announcing the new
PHD ULTRA™ Syringe Pumps

Click here for more information about PHD ULTRA™ Syringe Pumps and to download a brochure.

  • Patent pending mechanical design provides highest accuracy/precision & smoothest flow
  • Easy operation with advanced touch screen
  • Advanced EZ PRO™ software for PC functions without a PC.


Sign-up for a FREE Full Line Bioresearch Catalog
CLICK HERE!

  • Over 11,000 specialty products to enhance your bioresearch
  • Enhanced solutions for small animal research
  • 100's of pages of specialized information on instrumentation, applications, uses of products

 

Products on this website are for Research Use Only. Not for use in humans unless
proper investigational device regulations have been followed.


Privacy Policy   |   Terms and Conditions   
Copyright© Harvard Apparatus Ltd. - All rights reserved.
(44) 1223-423723
Website-related comments or concerns can be emailed to our webmaster.

Anesthesia Equipment Animal Handling Products Behavior Research Products Biological Measurement Products Cardiovascular Products Cell Biology Products Microincubation / Microinjectors CPK® Atomic Models Delivery & Sampling Products Dialysis / Sample Prep / SPE Electroporation / Transfection Electrophysiology Products General Laboratory Products Homeothermic/Temperature Control Isolated Organ & Isolated Tissue Molecular Biology Products Neuroscience Products Non-Invasive Blood Pressure Physiology Products Respiratory Products Stereotaxic Instruments Surgical Equipment Surgical Instruments Syringe Pumps/Peristaltic Pumps Tubing & Connectors Ventilators