Home Cardiovascular Products Transonic Flow Probes Standard Transonic Flow Probes 2 to 2.5 mm (S-Series - J Reflector with Slide Cover)


Larger Views

 

Standard Transonic Flow Probes 2 to 2.5 mm (S-Series - J Reflector with Slide Cover)

For direct measurement of volume flow for vessels from 1.5 to 2.5 mm diameter. These probes have the transducers positioned at a 60° angle to the vessel, reducing the flow probe body size and reflector width for placement of the probe in applications where space is limited. These Transonic Flow Probes work exclusively with the TTFM Transonic Time Flow Meter (73-0146). The TTFM Flow Meter requires a PLUGSYS Power Supply Case (Type 601, 603, or 609).
Search for Product in current catalog
Item Listing Full Description Specifications Journal Articles Manuals
Item# Description
734068 Standard Transonic Transit Time Flow Probe Type 2PSB, 1.5 to 2.0mm
734069 Standard Transonic Transit Time Flow Probe Type 2PSS, 1.5 to 2.0mm
734070 Standard Transonic Transit Time Flow Probe Type 2.5PSB, 1.8 to 2.5mm
734071 Standard Transonic Transit Time Flow Probe Type 2.5PSS, 1.8 to 2.5mm
734072 Standard Transonic Transit Time Flow Probe Type 2.5PSL, 1.8 to 2.5mm

For local pricing, contact your nearest distributor.



Full Description Back to Top

• Non-constrictive perivascular flowprobes
• For acute and chronic measurement of flow in arteries and veins
• large range of other vessel diameters from 500 m to 36 mm
• Probes for micro-measurements in mice or rats
• Probes with Dual-beam "X"-Pattern for ascending aorta flow measurement
• Inline Flowprobes for extracorporal circuits (Isolated perfused organs)

These Transonic Flow Probes work exclusively with the TTFM Transit Time Flow Meter (73-0146). The TTFM Flow Meter requires a PLUGSYS case (Type 601, 603, or 609). Probes type R and S are available with back cable exit (in a right angle to the vessel) or with side cable exit (parallel to the vessel). Please note Cable Exit specification before ordering to ensure you receive the configuration you require. All are configured for acute use with the TTFM Transit Time Flow Meter and are calibrated for blood at 37°C.

A range of Accessories and special connectors for chronic applications are available, please call for information.


Specifications Back to Top

Specifications734068734069734070734071734072
Vessel OD Acute1.5 - 2.0mm1.5 - 2.0mm1.8 - 2.5mm1.8 - 2.5mm1.8 - 2.5mm
Resolution Metric0.1ml/min0.1ml/min0.1ml/min0.1ml/min0.1ml/min
Range Sc Low Metric25ml/min25ml/min25ml/min25ml/min25ml/min
Range Sc Normal Metric100ml/min100ml/min100ml/min100ml/min100ml/min
Range Sc Maximum Metric500ml/min500ml/min500ml/min500ml/min500ml/min
Probe Length Metric8.7mm8.7mm8.7mm8.7mm8.7mm
Probe Width Metric3.3mm3.3mm3.3mm3.3mm3.3mm
Cable Length Metric1m1m1m1m1m
SeriesS-SeriesS-SeriesS-SeriesS-SeriesS-Series
Probe Type2PSB–HSE2PSS–HSE2.5PSB–HSE2.5PSS–HSE2.5PSL–HSE
Cable ExitBackSideBackSideLateral

Back to Top



Journal Articles Back to Top

Displaying 1 to 10 of 75results for Standard Transonic Flow Probes 2 to 2.5 mm (S-Series - J Reflector with Slide Cover)   Page 1  2  3  4  5  6  7  8 

Score

Document

Description

100% Login to view PP19 Pulsatile Flow Pump.pdf
[540 KB]
Pulsatile Flow Pump use in finding Real-Time Color Flow MRI
54% Login to view OT13 csf.pdf
[115 KB]
Dialysis Probes use in Release of Hypocretin (Orexin) during Waking and Sleep States
46% Login to view PP19 Real-Time Color Flow MRI.pdf
[193 KB]
Decreased Antigenicity of Apa Related to Modified Glycosylation
42% Login to view PP83 Design and Implementation of A Rapid-Mixer Flow-Cell For Time-Resolved Infrared Microspectroscopy.pdf
[124 KB]
Design and implementation of a rapid-mixer flow-cell for time-resolved infrared microspectroscopy
42% Login to view HB09 Two-Photon Imaging of Capillary Blood Flow in Olfactory Bulb Glomeruli.pdf
[989 KB]
Two-photon imaging of capillary blood flow in olfactory bulb golmeruli
37% Login to view flow thru dial.pdf
[387 KB]
A Novel Approach for the Extraction and Concentration of Compounds in Biological Fluids via On-Line Dialysis and Enrichment
34% Login to view VT09 Lung CD25 CD4 Regulatory T Cells Suppress Type 2 Immune Responses but not Bronchial Hyperreactivity.pdf
[131 KB]
JAP December 87/6
32% Login to view OT24.pdf
[692 KB]
Membrane transport of camptothecin: facilitation by human P-glycoprotein (ABCB1) and multidrug resistance protein 2 (ABCC2)
30% Login to view PP148.pdf
[91 KB]
Validation Of A Laser Flow Visualization Method To Measure Effective Flow Areas For Bileaflet Mechanical Valves
29% Login to view PP15 Model 22 Syringe Pump.pdf
[225 KB]
Syringe Infusion Pump use for An Investigation of Three-Phase Flow
   

Back to Top



Manuals Back to Top

Displaying 1 to 4 of 4results for Standard Transonic Flow Probes 2 to 2.5 mm (S-Series - J Reflector with Slide Cover)  

Score

Document

Description

100% Login to view PumpingComponent Milliliter.pdf
[1.2 MB]
Milliliter Flow M.P.C Modular Pumping Component Manual
94% Login to view Flow-Thru DIALYZER.pdf
[102 KB]
Flow-Thru DIALYZER
84% Login to view 703005 PHD ULTRA Manual.pdf
[2.4 MB]
PHD Ultra Syringe Pumps Manual - Standard/Remote/Programmable
71% Login to view VT0168 1.PDF
[229 KB]
2,3-Butanedione Monoxime Cardioplegia: Advantages Over Hyperkalemia in Blood-Perfused Isolated Hearts
   

Back to Top

Breakthrough Products for Regenerative Medicine
2011 Regenerative Medicine Brochure
100's of Innovative products developed with leading scientists & surgeons!
  • Injection & Perfusion
  • Bioreactors
  • Biosensing
  • Total Solutions
  • Total Support


Announcing the new
PHD ULTRA™ Syringe Pumps

Click here for more information about PHD ULTRA™ Syringe Pumps and to download a brochure.

  • Patent pending mechanical design provides highest accuracy/precision & smoothest flow
  • Easy operation with advanced touch screen
  • Advanced EZ PRO™ software for PC functions without a PC.


Sign-up for a FREE Full Line Bioresearch Catalog
CLICK HERE!

  • Over 11,000 specialty products to enhance your bioresearch
  • Enhanced solutions for small animal research
  • 100's of pages of specialized information on instrumentation, applications, uses of products

 

Products on this website are for Research Use Only. Not for use in humans unless
proper investigational device regulations have been followed.


Privacy Policy   |   Terms and Conditions   
Copyright© Harvard Apparatus Ltd. - All rights reserved.
(44) 1223-423723
Website-related comments or concerns can be emailed to our webmaster.

Anesthesia Equipment Animal Handling Products Behavior Research Products Biological Measurement Products Cardiovascular Products Cell Biology Products Microincubation / Microinjectors CPK Atomic Models Delivery & Sampling Products Dialysis / Sample Prep / SPE Electroporation / Transfection Electrophysiology Products General Laboratory Products Homeothermic/Temperature Control Isolated Organ & Isolated Tissue Molecular Biology Products Neuroscience Products Non-Invasive Blood Pressure Physiology Products Respiratory Products Stereotaxic Instruments Surgical Equipment Surgical Instruments Syringe Pumps/Peristaltic Pumps Tubing & Connectors Ventilators