Welcome to Harvard Apparatus UK! Login / Register
Search

Search for these keywords
Home Catalogs Online Technical Resources My Account
Advanced Search   
Products by Category

Featured Products
Warner Cell Electrophysiology & Cell Biology Research
Hugo Sachs Elektronic Isolated Organ and Tissue Systems
BTX Electroporation and Electrofusion Products
Panlab Behavior Research Products
Hoefer Electrophoresis Products
Coulbourn Instruments
Clark Glass Products
Navicyte Ussing/Diffusion Chambers
CMA
Harvard Apparatus
 

Home Cell Biology Products Micromanipulators Micromanipulator DC Microdrive Type 864/1


Larger Views

 

Micromanipulator DC Microdrive Type 864/1

The motorized micrometer drive Type 864/1 is based on the motor X axis of the long-established micromanipulator DC-3K. Together with the HSE-HA Microdrive Controller Type 864 it permits remotely controlled displacement of microelectrodes or capillaries, e.g. in intracellular potential recording, patch clamp experiments or stereotaxic investigations in the brain. It thus represents a complete alternative to hydraulic micro drives which have now become very expensive. The mechanism is based on a conventional micrometer screw with a displacement of 10 mm. The micrometer scale is visible and permits reading to 10 m. The drive is powered by a flange-mounted DC motor with gearbox. The micrometer drive slider moves on a precision crossed-roller guide.
Search for Product in current catalog
Item Listing Full Description Specifications Journal Articles Manuals
Item# Description
730003 DC Microdrive Type 864/1

For local pricing, contact your nearest distributor.



Full Description Back to Top

• Resolution down to 2 m

The motorized micrometer drive Type 864/1 is based on the motor X axis of the long-established micromanipulator DC-3K. Together with the HSE-HA Microdrive Controller Type 864 it permits remotely controlled displacement of microelectrodes or capillaries, e.g. in intracellular potential recording, patch clamp experiments or stereotaxic investigations in the brain. It thus represents a complete alternative to hydraulic micro drives which have now become very expensive. The mechanism is based on a conventional micrometer screw with a displacement of 10 mm. The micrometer scale is visible and permits reading to 10 m. The drive is powered by a flange-mounted DC motor with gearbox. The micrometer drive slider moves on a precision crossed-roller guide.
The excellent rolling properties of the guide ensure absence of sticking and sliding friction, and therefore no stick-slip effect, so that this design is ideally suitable for precision displacement systems. The micrometer drive is mounted at its back through a 7 mm dia. mounting bolt parallel to the working axis. The drive can therefore be mounted e.g. on the non-remote-control micromanipulator MM-3 in place of the microelectrode holder. Sizes without fitted microelectrode holder and mounting bolt


Specifications Back to Top

Specifications730003
Height Metric112 cm
Height English4.4 in
Width Metric25.0 cm
Width English1 in
Depth Metric32 cm
Depth English1.3 in
Weight Metric320 g
Weight English11.3 oz
SpindlePrecision micrometer
Displacement Range Metric10 mm
Resolution Metric2 m
DriveDC motor (12 V, 100 mA nom. current)
GearboxSpur gearing; compensation of gearing backlash is through backlash correction setting of HSE Microdrive Controller Type 864
Connection CableFoil-screened cable with moulded Mini-DIN plug suitable for HSE Microdrive Controller Type 864 (approx. 1.60 m long)
ScaleAccording to displacement, 0 to 10 mm, reading accuracy 10 m
CaseRigid aluminium, black anodized
MountingOn back, offset 7 mm clamping bolt parallel to working axis

Back to Top



Journal Articles Back to Top

Displaying 1 to 10 of 12results for Micromanipulator DC Microdrive Type 864/1   Page 1  2 

Score

Document

Description

100% Login to view PP76 Microdrive Pump.pdf
[99 KB]
Characterization of Hop Acids by Liquid Chromatography with Negative Electrospray Ionization Mass Spectrometry
38% Login to view Ca21-sensitive Inactivation and Facilitation of L-type Ca21 Channels.pdf
[235 KB]
Ca21-sensitive Inactivation and Facilitation of L-type Ca21 Channels Both Depend on Specific Amino Acid Residues in a Consensus Calmodulin-binding Motif in thea1C subunit
34% Login to view HS11 Type 211 Stimulator.pdf
[94 KB]
Stimulator use in finding native tetanus and pertussis toxins effect on electrical and chemical seizures in mice
23% Login to view PP02 micdrvpmp.pdf
[212 KB]
Microdrive Pump use in finding Intake of High-Fat Food is Selectively Enhanced by Mu Opioid Receptor Stimulation within the Nucleus Accumbens
23% Login to view PP40MI 1.PDF
[978 KB]
Microdrive Infusion Pump use in finding Impairment in a Discrimination Reversal Task After D1 Receptor Blockade in the Pigeon "Prefrontal Cortex"
21% Login to view WR06 OC724 Amplifier.pdf
[223 KB]
Mutational Analysis of CaM-mediated L-type Channel Modulation
21% Login to view HS05EL 1.PDF
[91 KB]
Electromechanical transducer and the role of histamine in cardiac muscle function
18% Login to view VT39.pdf
[850 KB]
THE STUDY OF THE EFFECT OF ENOXIMONE A PHOSPHODIESTERASE TYPE III INHIBITOR-VERSUS ADRENALINE IN CASES OF ACUTE MYOCARDIAL INFARCTION IN AN EXPERIMENTAL CAT MODEL
17% Login to view VT09 Lung CD25 CD4 Regulatory T Cells Suppress Type 2 Immune Responses but not Bronchial Hyperreactivity.pdf
[131 KB]
JAP December 87/6
16% Login to view VT09 immun2003.pdf
[458 KB]
Lung CD25 CD4 Regulatory T Cells Suppress Type 2 Immune Responses but not Bronchial Hyperreactivity
   

Back to Top



Manuals Back to Top

Displaying 1 to 1 of 1result for Micromanipulator DC Microdrive Type 864/1  

Score

Document

Description

100% Login to view DC Signal Conditioner.pdf
[166 KB]
DC Signal Conditioner manual
   

Back to Top

Breakthrough Products for Regenerative Medicine
2011 Regenerative Medicine Brochure
100's of Innovative products developed with leading scientists & surgeons!
  • Injection & Perfusion
  • Bioreactors
  • Biosensing
  • Total Solutions
  • Total Support


Announcing the new
PHD ULTRA™ Syringe Pumps

Click here for more information about PHD ULTRA™ Syringe Pumps and to download a brochure.

  • Patent pending mechanical design provides highest accuracy/precision & smoothest flow
  • Easy operation with advanced touch screen
  • Advanced EZ PRO™ software for PC functions without a PC.


Sign-up for a FREE Full Line Bioresearch Catalog
CLICK HERE!

  • Over 11,000 specialty products to enhance your bioresearch
  • Enhanced solutions for small animal research
  • 100's of pages of specialized information on instrumentation, applications, uses of products

 

Products on this website are for Research Use Only. Not for use in humans unless
proper investigational device regulations have been followed.


Privacy Policy   |   Terms and Conditions   
Copyright© Harvard Apparatus Ltd. - All rights reserved.
(44) 1223-423723
Website-related comments or concerns can be emailed to our webmaster.

Anesthesia Equipment Animal Handling Products Behavior Research Products Biological Measurement Products Cardiovascular Products Cell Biology Products Microincubation / Microinjectors CPK Atomic Models Delivery & Sampling Products Dialysis / Sample Prep / SPE Electroporation / Transfection Electrophysiology Products General Laboratory Products Homeothermic/Temperature Control Isolated Organ & Isolated Tissue Molecular Biology Products Neuroscience Products Non-Invasive Blood Pressure Physiology Products Respiratory Products Stereotaxic Instruments Surgical Equipment Surgical Instruments Syringe Pumps/Peristaltic Pumps Tubing & Connectors Ventilators