Optional/Replacement Headstages for Oocyte Clamp

The OC-725C Oocyte Clamp is designed for two-electrode, whole-cell voltage clamping of Xenopus oocytes. The dedicated design of the OC-725C includes such features as high compliance voltage (±180 V) and unique bath clamp circuitry. These same features also make the OC-725C ideal for clamping other large cells and cell structures such as squid axons. Improvements to this version include an extended current measuring range, decreased noise level and a 4-pole Bessel filter.
Search for Product in current catalog
Item Listing Full Description Journal Articles
Item# Description
640030 7255DI Optional Differential Headstage for Oocyte Clamp
640031 7250V Replacement Voltage Headstage for Oocyte Clamp
640032 7251I Replacement Bath Clamp Headstage for Oocyte Clamp
640033 7259C Replacement Current Electrode Cable for Oocyte Clamp
640029 725MC Model Cell for Oocyte Clamp

For local pricing, contact your nearest distributor.



Full Description Back to Top


The OC-725C Oocyte Clamp is designed for two-electrode, whole-cell voltage clamping of Xenopus oocytes. The dedicated design of the OC-725C includes such features as high compliance voltage (±180 V) and unique bath clamp circuitry. These same features also make the OC-725C ideal for clamping other large cells and cell structures such as squid axons. Improvements to this version include an extended current measuring range, decreased noise level and a 4-pole Bessel filter.

Fast Stable Voltage Clamping
The OC-725C combines high AC and DC gains and a voltage compliance of ±180 volts to insure fast, nonsaturating clamp performance under nearly any condition. The AC clamp gain is variable up to 2000. An additional DC gain of 1 x 106 may be employed for high conductance cells (leaky oocytes).
Two clamp speeds are available: The Slow mode is used for screening oocytes or for applications not requiring fast response times. The Fast mode is used for accurate voltage clamp of fast whole cell currents. Clamp response time in the Fast mode is 350 µsec (10-90% rise time) when applying a 100 mV step to a model cell, see specifications on facing page.

Improved Bath Clamp Headstage
The current measuring range of the OC-725C bath clamp headstage has been extended at both ends by the addition of a 3 position range multiplier. Smaller currents are amplified to usable levels and larger currents up to 1 mA can be recorded without output saturation. The unique design of the bath clamp eliminates the need for series resistance compensation. It provides an accurate measurement of bath current by creating a virtual ground in the bath while simultaneously clamping the bath potential at zero.

Voltage Headstage Probe
The voltage measuring headstage is a single-ended, high-impedance probe. Its small size, convenient mounting rod and 2 meter cable make for easy attachment to a micropositioner. The headstage input is a 2 mm diameter pin. An electrode holder with a 2 mm jack (supplied) mounts directly on the headstage.

Voltage & Current Meters
Independent meters provide simultaneous displays of membrane voltage Vm and membrane current Im. To assure proper impalement of the current electrode, the current meter displays membrane potential Ve from the current electrode before the clamp circuit is turned on.

Clamp Commands
The internal Hold control is a digital push button control with two ranges; ±1 to 99 mV (x1) and ±2 to 198 mV (x2). Hold can be incremented in steps of 1, 2, 10 and 20 mV for I-V studies. External command signals applied to Command IN ÷10 are attenuated to reduce noise from the command source. Hold and external commands are summed.

Additional Features
• Buzz controls (1 kHz square wave) for each electrode aid in penetration of cell membranes with a minimum of leakage.
• Overload alarm (audible and visual) indicate when the compliance voltage is exceeded safeguarding the oocyte and indicating that current records are subject to saturation.
• DC Offsets for both voltage and current electrodes.
• Electrode Test for both electrodes.
• Capacity Compensation for the Vm voltage input.

Electrode Holders
Two vented electrode holders with silver wires are typically required with the clamp; a straight type for use with the voltage headstage and a 45° type with mounting handle for use with current electrodes. Vents have been added to the electrodes to prevent pressure build-up inside the electrode which can damage oocytes.
These holders are available separately. Select the holder based on your glass outer diameter. Unvented holders are available and have a “N” at the end of the model number. Vented holders have a “V” on the end of the model number. A two meter length cable assembly is provided to connect the current electrode holder to the clamp.

Dual Oocyte Studies
Some studies, such as voltage control across gap junctions, require the clamping of two oocytes in a common bath using two voltage clamps. The combined currents from the two oocytes cause problems because the bath clamp headstage cannot separate the individual currents and therefore cannot provide effective clamping.

OC-725C has two features to address these problems:
• An internal switch permits measurements of the current in series with the current electrode instead of in the bath.
• Optional differential voltage headstages (7255 DI): The differential measurement subtracts the voltage drop across the series resistance in the bath, which is normally eliminated by the bath clamp.


Journal Articles Back to Top

Displaying 1 to 6 of 6results for Optional/Replacement Headstages for Oocyte Clamp  

Score

Document

Description

100% Login to view WR11 Oocyte Clamp Amplifier.pdf
[453 KB]
Oocyte Clamp Amplifier use in finding 4-Methylhomoibotenic Acid Activates a Novel Metabotropic Glutamate Receptor Coupled to Phosphoinostide
30% Login to view 4-Methylhomoibotenic Acid Activates a Novel Metabotropic.pdf
[453 KB]
Oocyte Clamp Amplifier use in finding 4-Methylhomoibotenic Acid Activates a Novel Metabotropic Glutamate Receptor Coupled to Phosphoinostide
30% Login to view WR08 OC725 Amplifier.pdf
[192 KB]
Oocyte Clamp use in finding Cation Selectivity of Gastric H,K-ATPase and Na,K-ATPase Chimeras
26% Login to view Cation Selectivity of Gastric H,K-ATPase.pdf
[199 KB]
Oocyte Clamp use in finding Cation Selectivity of Gastric H,K-ATPase and Na,K-ATPase Chimeras
19% Login to view WR20 OC725C.pdf
[168 KB]
Inactivation of Kv2.1 Potassium Channels with use of Voltage-Clamp Amplifier
17% Login to view Inactivation of Kv2.1 Potassium Channels.pdf
[183 KB]
Inactivation of Kv2.1 Potassium Channels with use of Voltage-Clamp Amplifier
   

Back to Top

Breakthrough Products for Regenerative Medicine
2011 Regenerative Medicine Brochure
100's of Innovative products developed with leading scientists & surgeons!
  • Injection & Perfusion
  • Bioreactors
  • Biosensing
  • Total Solutions
  • Total Support


Announcing the new
PHD ULTRA™ Syringe Pumps

Click here for more information about PHD ULTRA™ Syringe Pumps and to download a brochure.

  • Patent pending mechanical design provides highest accuracy/precision & smoothest flow
  • Easy operation with advanced touch screen
  • Advanced EZ PRO™ software for PC functions without a PC.


Sign-up for a FREE Full Line Bioresearch Catalog
CLICK HERE!

  • Over 11,000 specialty products to enhance your bioresearch
  • Enhanced solutions for small animal research
  • 100's of pages of specialized information on instrumentation, applications, uses of products

 

Products on this website are for Research Use Only. Not for use in humans unless
proper investigational device regulations have been followed.


Privacy Policy   |   Terms and Conditions   
Copyright© Harvard Apparatus Ltd. - All rights reserved.
(44) 1223-423723
Website-related comments or concerns can be emailed to our webmaster.

Anesthesia Equipment Animal Handling Products Behavior Research Products Biological Measurement Products Cardiovascular Products Cell Biology Products Microincubation / Microinjectors CPK® Atomic Models Delivery & Sampling Products Dialysis / Sample Prep / SPE Electroporation / Transfection Electrophysiology Products General Laboratory Products Homeothermic/Temperature Control Isolated Organ & Isolated Tissue Molecular Biology Products Neuroscience Products Non-Invasive Blood Pressure Physiology Products Respiratory Products Stereotaxic Instruments Surgical Equipment Surgical Instruments Syringe Pumps/Peristaltic Pumps Tubing & Connectors Ventilators