Welcome to Harvard Apparatus UK! Login / Register
Search

Search for these keywords
Home Catalogs Online Technical Resources My Account
Advanced Search   
Products by Category

Featured Products
Warner Cell Electrophysiology & Cell Biology Research
Hugo Sachs Elektronic Isolated Organ and Tissue Systems
BTX Electroporation and Electrofusion Products
Panlab Behavior Research Products
Hoefer Electrophoresis Products
Coulbourn Instruments
Clark Glass Products
Navicyte Ussing/Diffusion Chambers
CMA
Harvard Apparatus
 

Home Anesthesia Equipment Evacuation Systems AES Active Gas Evacuation Systems


Larger Views

 

AES Active Gas Evacuation Systems

The Anesthetic Evacuation System (AES) will safely and actively remove waste gas associated with everyday inhalation anesthesia. It can be mounted on the pole of the CDS-2000, Vaporstick Plus or Vaporstick, see pages F16 to F17. It can also be used as a freestanding unit and simply placed on the benchtop. Two standard 19 mm (0.75 inch) inlets and one exhaust port allows easy hook-up to existing equipment. A 12 foot grounded electrical cord and lightweight tubing, allows for machine maneuverability.
Search for Product in current catalog
Item Listing Full Description Specifications Journal Articles Manuals
Item# Description
723064 AES Active Gas Evacuation, 110 VAC 60 Hz
723065 AES Active Gas Evacuation, 220 VAC 50 Hz
723093 AES Tubing 19 mm (0.75 in) ID , 3 m (10 ft) length
723085 AES Male Adapters 19 mm X 19 mm
723070 AES Ceiling Plate Cover

For local pricing, contact your nearest distributor.



Full Description Back to Top

• Powered unit for safe and effective removal of anesthetic waste gas
• Can be mounted to anesthesia machine pole or used as a free standing unit
• Two inlet ports allow connection to an induction chamber and an anesthesia machine simultaneously

The Anesthetic Evacuation System (AES) will safely and actively remove waste gas associated with everyday inhalation anesthesia. It can be mounted on the pole of the CDS-2000, Vaporstick Plus or Vaporstick. It can also be used as a freestanding unit and simply placed on the benchtop. Two standard 19 mm (0.75 inch) inlets and one exhaust port allows easy hook-up to existing equipment. A 12 foot grounded electrical cord and lightweight tubing, allows for machine maneuverability.

The waste gas from the pop-off valve on most rebreathing anesthesia machines is collected by passive flow to the AES. This allows for safe operation of the anesthesia machine with little or no vacuum exposure. Using a push blower, the AES actively removes the waste gas from the unit. The blower has the capacity of moving 12 cubic feet/minute through up to 150 feet of tubing to an outside vent or fume hood. The on/off switch illuminates a green light when the unit is activated. The ‘on’ light assures the operator that the unit is functioning.

The Anesthetic Evacuation System includes a 3 inch and a 10 foot length of 19 mm ID hose and a 12.5 mm (0.5 inch) PVC Adapter. Additional lengths of tubing may be required and are available as an option along with an adapter to interconnect the 19 mm outlet tubing. An optional outlet line ceiling plate is available when connection to an outside wall is not convenient.


Specifications Back to Top

Specifications723064723065723093723085723070
Power110 VAC 60 Hz220 VAC 50 Hz   
Length English*na ft*na ft10 ft*na ft*na ft
Length Metric*na m*na m3 m*na m*na m
ID Metric*na mm*na mm19 mm19 mm*na mm
ID English*na in*na in0.75 in0.75 in*na in

Back to Top



Journal Articles Back to Top

Displaying 1 to 8 of 8results for AES Active Gas Evacuation Systems  

Score

Document

Description

100% Login to view PP69 PHD 2000 Syringe Pump.pdf
[598 KB]
Passive mixing in a three-dimensional serpentine microchannel - Microelectromechanical Systems, Journal of
46% Login to view HB01 Assessment of Tissue Oxygen Tension.pdf
[270 KB]
Homeothermic Blanket Assessment of tissue oxygen tension
46% Login to view HB03 Leukotriene B4 Promotes Reactive Oxidant Generation and Leukocyte Adherence During Acute Hypoxia.pdf
[198 KB]
Homeothermic Blanket Leukotrience B4 promotes reactive oxidant generation and leukocyte adherence during acute hypoxia
46% Login to view HB04 Intracellularly Labeled Fusiform Cells in Dorsal Cochlear Nucleus of hte Gerbil.pdf
[475 KB]
Homeothermic Blanket Intracellularly Labeled Fusiform Cells in Dorsal Cochlear Nucleus of the Gerbil
46% Login to view HB06 Neuroprotein and Neurotoxicity Studies in Rats.pdf
[523 KB]
Intracellular Response Properties of Units in the Dorsal Cochlear Nucleus of Unanesthetized Decerebrate Gerbil
23% Login to view HB02 Regulation of Transcription by a Protein Methyltransferase.pdf
[264 KB]
23% Login to view HB08 mri bkt 3.pdf
[272 KB]
VEGF antagonism reduces edema formation and tissue damage after ischemia/reperfusion injury in the mouse brain
23% Login to view HB09 Two-Photon Imaging of Capillary Blood Flow in Olfactory Bulb Glomeruli.pdf
[989 KB]
Two-photon imaging of capillary blood flow in olfactory bulb golmeruli
   

Back to Top



Manuals Back to Top

Displaying 1 to 2 of 2results for AES Active Gas Evacuation Systems  

Score

Document

Description

100% Login to view Perfusion Tissue Systems Guide.pdf
[105 KB]
New BS4_K_Isolated Organ.qxd
59% Login to view Ussing Chamber Systems.pdf
[1.5 MB]
Guide to Ussing Chamber Systems
   

Back to Top

Breakthrough Products for Regenerative Medicine
2011 Regenerative Medicine Brochure
100's of Innovative products developed with leading scientists & surgeons!
  • Injection & Perfusion
  • Bioreactors
  • Biosensing
  • Total Solutions
  • Total Support


Announcing the new
PHD ULTRA™ Syringe Pumps

Click here for more information about PHD ULTRA™ Syringe Pumps and to download a brochure.

  • Patent pending mechanical design provides highest accuracy/precision & smoothest flow
  • Easy operation with advanced touch screen
  • Advanced EZ PRO™ software for PC functions without a PC.


Sign-up for a FREE Full Line Bioresearch Catalog
CLICK HERE!

  • Over 11,000 specialty products to enhance your bioresearch
  • Enhanced solutions for small animal research
  • 100's of pages of specialized information on instrumentation, applications, uses of products

 

Products on this website are for Research Use Only. Not for use in humans unless
proper investigational device regulations have been followed.


Privacy Policy   |   Terms and Conditions   
Copyright© Harvard Apparatus Ltd. - All rights reserved.
(44) 1223-423723
Website-related comments or concerns can be emailed to our webmaster.

Anesthesia Equipment Animal Handling Products Behavior Research Products Biological Measurement Products Cardiovascular Products Cell Biology Products Microincubation / Microinjectors CPK® Atomic Models Delivery & Sampling Products Dialysis / Sample Prep / SPE Electroporation / Transfection Electrophysiology Products General Laboratory Products Homeothermic/Temperature Control Isolated Organ & Isolated Tissue Molecular Biology Products Neuroscience Products Non-Invasive Blood Pressure Physiology Products Respiratory Products Stereotaxic Instruments Surgical Equipment Surgical Instruments Syringe Pumps/Peristaltic Pumps Tubing & Connectors Ventilators