Welcome to Harvard Apparatus UK! Login / Register
Search

Search for these keywords
Home Catalogs Online Technical Resources My Account
Advanced Search   
Products by Category

Featured Products
Warner Cell Electrophysiology & Cell Biology Research
Hugo Sachs Elektronic Isolated Organ and Tissue Systems
BTX Electroporation and Electrofusion Products
Panlab Behavior Research Products
Hoefer Electrophoresis Products
Coulbourn Instruments
Clark Glass Products
Navicyte Ussing/Diffusion Chambers
CMA
Harvard Apparatus
 

Home Non-Invasive Blood Pressure NIBP System with Transilluminated LED & Photodiode Sensor Single/Dual Channel Operation Blood Pressure Analysis Systems


Larger Views

 

Single/Dual Channel Operation Blood Pressure Analysis Systems

The SC1000 combines the latest in blood pressure analysis technology with the economy of single channel operation. Measurement results include Pulse Rate, Systolic, Diastolic, and MAP. The system is expandable by easily adding a second specimen platform for use with either mice or rats. All measurement results correlate precisely with intra-arterial methods and the data is automatically saved for exporting to any common spreadsheet. The SC1000 is accurate, efficient and time saving.
Search for Product in current catalog
Item Listing Full Description Specifications Journal Articles Manuals
Item# Description
727073 SC1000 Blood Pressure Analysis System for Mice, 85 to 240 VAC, 50/60 Hz**Note: All units are supplied with USA standard power cords.
727074 SC1000 Blood Pressure Analysis System for Rats, 85 to 240 VAC, 50/60 Hz**Note: All units are supplied with USA standard power cords.
727075 Additional Mouse Platform with Size 1 Mouse Holder and CAT5 Cable
727076 Additional Rat Platform with Size 1 Rat Holder and CAT5 Cable
727078 SC1000 Comm for Windows® Software
727079 SC1000 Palm OS® Version Software
727077 Palm PDA (consult factory for models available)

For local pricing, contact your nearest distributor.



Full Description Back to Top

• Single or Dual Channel Operation (requires additional specimen platform)
• Simultaneous measurements on two animals
• “V-Notch” sensor assembly helps to stabilize the tail
• Interchangeable Specimen Platforms
• Uses standard latex balloons in tail-cuff
• Rugged all metal construction with epoxy coating
• Holders available in four standard sizes
• Custom Algorithms designed specifically for non-invasive measurements
• Fast and Accurate measurements for pulse, diastolic, systolic and MAP
• Precise Correlation with intra-arterial measurements

The SC1000 combines the latest in blood pressure analysis technology with the economy of single channel operation. Measurement results include Pulse Rate, Systolic, Diastolic, and MAP. The system is expandable by easily adding a second specimen platform for use with either mice or rats. All measurement results correlate precisely with intra-arterial methods and the data is automatically saved for exporting to any common spreadsheet. The SC1000 is accurate, efficient and time saving.
The SC1000 incorporates custom algorithms for measuring diastolic blood pressure independently of systolic pressure. Other systems calculate the diastolic pressure based on the systolic measurement. The parameter settings for determining diastolic and systolic BP are adjustable by the user. This feature allows the user to make adjustments to the system settings for correlation with simultaneous intra-arterial measurements.
Measurement data collected by the SC1000 can be retrieved by the user by paging through the measurement results with the keypad and recording them manually as they are displayed on the vacuum fluorescent display. A more automated collection method can by utilized by connecting the SC1000 to a Palm Pilot or other PDA through the onboard RS232 serial port. The PDA Interface works with any Palm OS® based system such as a Palm IIIc® or other handheld device. By using the PDA Interface, measurement data can be automatically stored. The stored data can be imported to a PC for viewing the measurement waveforms. For complete automation, the SC1000 may be connected to a notebook or desktop computer for data collection and control, real-time viewing of the pulse waveform, and storage of all results and waveform data in computer files. The results data and associated waveforms can be retrieved at any time for review and analysis. In addition, the results data can be exported as a .csv file for use in any common spreadsheet.
Pulse Detection is accomplished with a very sensitive solid-state photodiode detector in combination with a high intensity light emitting diode. The specially designed “V” shaped sensor assembly helps stabilize the animals’ tail.
The animal holders are especially designed to minimize the difficulty of securing untrained animals when making blood pressure measurements. Each system is supplied with one size 1 specimen holder. Other size holders are available separately. The control unit can accept a second specimen platform thus making it a dual channel system. The specimen platform is species specific, but the control unit is non-specific. Therefore you may use 2 rat platforms, 2 mice platforms or 1 rat and 1 mouse platform.The SC1000 Blood Pressure Analysis System includes:
• Master Control Unit
• Specimen Platform for either mouse or rat with one size 1 specimen holder
• Airline, power cable and interconnect cable
• Accessory Kit (contains tail-cuff balloons, tool for making end caps, etc.)
• Operator’s Manual
The following is optional equipment or software:
• Additional specimen platform
• Different size specimen holders
• Palm PDA (consult factory for models available)
• SC1000 Palm OS® Version Software
• SC1000 Comm for Windows® Software


Specifications Back to Top

Specifications727073727074727075727076727078727079727077
Power85 to 240 VAC, 50/60 Hz**Note: All units are supplied with USA standard power cords.85 to 240 VAC, 50/60 Hz**Note: All units are supplied with USA standard power cords.     
AnimalMouseRatMouseRat   
Size  11   

Back to Top



Journal Articles Back to Top

Displaying 1 to 10 of 64results for Single/Dual Channel Operation Blood Pressure Analysis Systems   Page 1  2  3  4  5  6  7 

Score

Document

Description

100% Login to view HS08 pressure transducer.pdf
[46 KB]
Pressure Transducer use in finding blood pressure and heart rate spectral changes
55% Login to view HB09 Two-Photon Imaging of Capillary Blood Flow in Olfactory Bulb Glomeruli.pdf
[989 KB]
Two-photon imaging of capillary blood flow in olfactory bulb golmeruli
44% Login to view PP69 PHD 2000 Syringe Pump.pdf
[598 KB]
Passive mixing in a three-dimensional serpentine microchannel - Microelectromechanical Systems, Journal of
43% Login to view Protein kinase C inhibits Kv1.1 potassium channel function.pdf
[324 KB]
Protein Kinase C inhibits Kv1.1 potassium channel function
40% Login to view Protein kinase C inhibits Kv1.1 potassium channel function2.pdf
[333 KB]
OC-725B Amolifier use in finding Protein kinase C inhibits Kv1.1 potassium channel function
38% Login to view VT31 Sickle RBC's and NOS Inhibition decrease rat cerebral blood flow.pdf
[515 KB]
Sickle RBC's and NOS Inhibition decrease rat cerebral blood flow
37% Login to view PP182.pdf
[1.7 MB]
Capillary Electrophoresis. and Microchip.Mass Spectrometry Interfaces and Their Utilization in Bisphosphonate Analysis
37% Login to view PP50 Blood Pump Model 1421.pdf
[141 KB]
Analysis of Slipstream Flow in a Wide-necked Basilar Artery Aneurysm with use of Blood Pump
36% Login to view WR06 OC724 Amplifier.pdf
[223 KB]
Mutational Analysis of CaM-mediated L-type Channel Modulation
34% Login to view PP50 Analysis of Slipstream Flow in a Wide-Necked Basilar Artery Aneurysm.pdf
[136 KB]
Analysis of Slipstream Flow in a Wide-necked Basilar Artery Aneurysm with use of Blood Pump
   

Back to Top



Manuals Back to Top

Displaying 1 to 7 of 7results for Single/Dual Channel Operation Blood Pressure Analysis Systems  

Score

Document

Description

100% Login to view 603002 603003.pdf
[77 KB]
Research Grade Blood Pressure Transducer Manual
98% Login to view Perfusion Tissue Systems Guide.pdf
[105 KB]
New BS4_K_Isolated Organ.qxd
90% Login to view 724488 724489.pdf
[124 KB]
Research Grade Blood Pressure Transducer Manual
79% Login to view Pump11 Plus.pdf
[1.1 MB]
Model 11 Plus Syringe Pump Manual
75% Login to view Model708 557081.pdf
[43 KB]
Harvard 708 Pressure Controlled Ventilator Manual
57% Login to view Nanoleader Pump Series NLS110P Pressure Pump Manual.pdf
[2.2 MB]
705000 NLS110P Pump Manual
55% Login to view VT0168 1.PDF
[229 KB]
2,3-Butanedione Monoxime Cardioplegia: Advantages Over Hyperkalemia in Blood-Perfused Isolated Hearts
   

Back to Top

Breakthrough Products for Regenerative Medicine
2011 Regenerative Medicine Brochure
100's of Innovative products developed with leading scientists & surgeons!
  • Injection & Perfusion
  • Bioreactors
  • Biosensing
  • Total Solutions
  • Total Support


Announcing the new
PHD ULTRA™ Syringe Pumps

Click here for more information about PHD ULTRA™ Syringe Pumps and to download a brochure.

  • Patent pending mechanical design provides highest accuracy/precision & smoothest flow
  • Easy operation with advanced touch screen
  • Advanced EZ PRO™ software for PC functions without a PC.


Sign-up for a FREE Full Line Bioresearch Catalog
CLICK HERE!

  • Over 11,000 specialty products to enhance your bioresearch
  • Enhanced solutions for small animal research
  • 100's of pages of specialized information on instrumentation, applications, uses of products

 

Products on this website are for Research Use Only. Not for use in humans unless
proper investigational device regulations have been followed.


Privacy Policy   |   Terms and Conditions   
Copyright© Harvard Apparatus Ltd. - All rights reserved.
(44) 1223-423723
Website-related comments or concerns can be emailed to our webmaster.

Anesthesia Equipment Animal Handling Products Behavior Research Products Biological Measurement Products Cardiovascular Products Cell Biology Products Microincubation / Microinjectors CPK® Atomic Models Delivery & Sampling Products Dialysis / Sample Prep / SPE Electroporation / Transfection Electrophysiology Products General Laboratory Products Homeothermic/Temperature Control Isolated Organ & Isolated Tissue Molecular Biology Products Neuroscience Products Non-Invasive Blood Pressure Physiology Products Respiratory Products Stereotaxic Instruments Surgical Equipment Surgical Instruments Syringe Pumps/Peristaltic Pumps Tubing & Connectors Ventilators