Welcome to Harvard Apparatus UK! Login / Register
Search

Search for these keywords
Home Catalogs Online Technical Resources My Account
Advanced Search   
Products by Category

Featured Products
Warner Cell Electrophysiology & Cell Biology Research
Hugo Sachs Elektronic Isolated Organ and Tissue Systems
BTX Electroporation and Electrofusion Products
Panlab Behavior Research Products
Hoefer Electrophoresis Products
Coulbourn Instruments
Clark Glass Products
Navicyte Ussing/Diffusion Chambers
CMA
Harvard Apparatus
 

Home Delivery & Sampling Products Swivels Dual Channel Infusion Swivels


Larger Views

 

Dual Channel Infusion Swivels

Introducing the latest breakthrough in swivel technology, the new 72-0000 Dual Channel Microdialysis Swivel for Mice! The torque required to rotate this remarkable new swivel is even lower than our 56-1324 Single Channel Swivel, making it the first dual channel swivel that can be used with mice. (See chart below.) Furthermore, it has quartz lining on both channels, making it the ultimate microdialysis swivel for mice, rats or any other small animal!
Search for Product in current catalog
Item Listing Full Description Specifications Journal Articles Manuals
Item# Description
610002 Harvard/Instech Stainless Steel Dual Channel Swivel 20 gauge, 0.023 in Center Channel ID, pkg. 1
720000 Harvard/Instech Stainless Steel Dual Channel Swivel 22 gauge, 0.006 in Center Channel ID, pkg. 1
610003 Harvard/Instech Stainless Steel Dual Channel Swivel 22 gauge, 0.016 in Center Channel ID, pkg. 1
610004 Harvard/Instech Stainless Steel Dual Channel Swivel 22 gauge, 0.006 in Center Channel ID, pkg. 1

For local pricing, contact your nearest distributor.



Full Description Back to Top

• New dual channel swivel that is truly suited for microdialysis in mice
• Setting the industry standard for 25 years
• Lifetime warranty on single channel swivels
• Fully autoclavable • A variety of sizes
• Tether included
• Custom swivels available by special order

Introducing the latest breakthrough in swivel technology, the new 72-0000 Dual Channel Microdialysis Swivel for Mice! The torque required to rotate this remarkable new swivel is even lower than our 56-1324 Single Channel Swivel, making it the first dual channel swivel that can be used with mice. (See chart below.) Furthermore, it has quartz lining on both channels, making it the ultimate microdialysis swivel for mice, rats or any other small animal!
The swivel, a device that rotates to keep the cannula from tangling, is a critical part of any continuous animal infusion system. The Harvard/Instech Fluid Swivels have been in laboratory use for more than 30 years and have earned a reputation as the finest in the industry.
Every swivel is precision machined to ensure ease of rotation, durability and reliability. The design minimizes internal dead volume and eliminates stagnant regions along the fluid path. Fluids passing through the swivel touch only stainless steel tubing and special self-adjusting PTFE seals. The 61-0004 Dual Channel 22 Gauge Swivel, designed specifically for microdialysis in rats, has a quartz-lined center channel to reduce dead volume and prevent oxidization of neurotransmitters. These Swivels are fully autoclavable and can be reused hundreds of times. In fact, our single channel swivel is so durable that it comes with a lifetime warranty! Our standard swivels are typically used with rats and mice, but work with rabbits, guinea pigs and, with a strain relief, larger animals as well. Each swivel includes a Universal Swivel-to-Tether Clamp, see page B6, that connects to all of our standard spring tethers. The standard swivels are manufactured in a variety of sizes, a few of which are listed below. For a complete listing of available sizes and custom orders or to select the best swivel for your application please call Harvard Apparatus Customer Service.
Harvard Apparatus also has a variety of complete infusion systems that contain the equipment you need to carry out an infusion study. Please visit our website for details at www.harvardapparatus.com. Custom swivels available by special order. Call for details.


Specifications Back to Top

Specifications610002720000610003610004
ApplicationBlood Pressure Measurements, Rapid Infusions, IV FeedingMicrodialysis for MiceStandard Infusion of RatsMicrodialysis with Rats
MaterialStainless SteelStainless SteelStainless SteelStainless Steel
Inlet & Outlet Tube Gauge20222222
Compatible Tubing Catalog Number598329597023598325597023
Center Channel ID English0.023 in0.006 in0.016 in0.006 in
Center Channel Dead Volume Metric18.0 ?l1.8 ?l8.0 ?l1.4 ?l
Side Channel ID English0.023 in0.006 in0.016 in0.016 in
Side Channel Dead Volume Metric18 ?l2.8 ?l18 ?l18 ?l
Length English2.38 in2.38 in2.38 in2.38 in
OD English0.375 in0.375 in0.375 in0.375 in

Back to Top



Journal Articles Back to Top

Displaying 1 to 10 of 53results for Dual Channel Infusion Swivels   Page 1  2  3  4  5  6 

Score

Document

Description

100% Login to view PP49 Infusion Pump.pdf
[120 KB]
Infusion Pump use in finding Drug-Protein Binding and Blood Brain Barrier Permeability
100% Login to view PP09 Infusion Pump.pdf
[224 KB]
Infusion Pump use in finding The Anygdala is Essential for the Developement of Neuronal Plasticity
76% Login to view PP54 Infusion Pump.pdf
[116 KB]
Ultrasound Doppler estimates of femoral artery blood flow during dynamic knee extensor exercise in humans
51% Login to view Protein kinase C inhibits Kv1.1 potassium channel function.pdf
[324 KB]
Protein Kinase C inhibits Kv1.1 potassium channel function
50% Login to view PP51 Infusion Pump.pdf
[151 KB]
Inhibition of Poly (ADP-Ribose) Polymerase with use of Infusion Pump
49% Login to view HS13 Cardioselective KATP Channel Blockers.pdf
[165 KB]
Force Transducer use in Cardioselective KATP Channel Blockers Derived from a New Series of Anisamidoethylbenzenesulfonylthioureas
48% Login to view PP67 Infusion Pump.pdf
[291 KB]
Infusion Pump use in finding Muscimol Inactivation of the Dorsal Hippocampus Impairs Contextual Retrieval of Fear Memory
47% Login to view Protein kinase C inhibits Kv1.1 potassium channel function2.pdf
[333 KB]
OC-725B Amolifier use in finding Protein kinase C inhibits Kv1.1 potassium channel function
44% Login to view WR06 OC724 Amplifier.pdf
[223 KB]
Mutational Analysis of CaM-mediated L-type Channel Modulation
41% Login to view PP107 mri pmp5.pdf
[295 KB]
Dual Syringe Pump use in finding Predictability Modulates Human Brain Response to Reward
   

Back to Top



Manuals Back to Top

Displaying 1 to 4 of 4results for Dual Channel Infusion Swivels  

Score

Document

Description

100% Login to view Swivel DualChannel 561431l.pdf
[40 KB]
Swivel Dual Channel Manual
100% Login to view Swivel DualChannel 561282.pdf
[40 KB]
Swivel Dual Channel Manual
100% Login to view Swivel DualChannel 596705.pdf
[40 KB]
Swivel Dual Channel Manual
91% Login to view Swivel DualChannel Repair.pdf
[37 KB]
Swivel Dual Channel Repair Manual
   

Back to Top

Breakthrough Products for Regenerative Medicine
2011 Regenerative Medicine Brochure
100's of Innovative products developed with leading scientists & surgeons!
  • Injection & Perfusion
  • Bioreactors
  • Biosensing
  • Total Solutions
  • Total Support


Announcing the new
PHD ULTRA™ Syringe Pumps

Click here for more information about PHD ULTRA™ Syringe Pumps and to download a brochure.

  • Patent pending mechanical design provides highest accuracy/precision & smoothest flow
  • Easy operation with advanced touch screen
  • Advanced EZ PRO™ software for PC functions without a PC.


Sign-up for a FREE Full Line Bioresearch Catalog
CLICK HERE!

  • Over 11,000 specialty products to enhance your bioresearch
  • Enhanced solutions for small animal research
  • 100's of pages of specialized information on instrumentation, applications, uses of products

 

Products on this website are for Research Use Only. Not for use in humans unless
proper investigational device regulations have been followed.


Privacy Policy   |   Terms and Conditions   
Copyright© Harvard Apparatus Ltd. - All rights reserved.
(44) 1223-423723
Website-related comments or concerns can be emailed to our webmaster.

Anesthesia Equipment Animal Handling Products Behavior Research Products Biological Measurement Products Cardiovascular Products Cell Biology Products Microincubation / Microinjectors CPK® Atomic Models Delivery & Sampling Products Dialysis / Sample Prep / SPE Electroporation / Transfection Electrophysiology Products General Laboratory Products Homeothermic/Temperature Control Isolated Organ & Isolated Tissue Molecular Biology Products Neuroscience Products Non-Invasive Blood Pressure Physiology Products Respiratory Products Stereotaxic Instruments Surgical Equipment Surgical Instruments Syringe Pumps/Peristaltic Pumps Tubing & Connectors Ventilators