ISOHEART® Isolated Heart Data Acquisition Software

The HSE-HA ISOHEART software for Windows can be adapted to virtually any experimental investigation of isolated hearts (according to Langendorff or Working Heart). Acquisition can cover signals such as perfusion pressure, perfusion flow, left ventricular pressure, aortic pressure, aortic flow, atrial pressure, atrial flow, coronary flow, segment length or wall thickness measurement, pO2, pCO2, pH, temperature, etc. Various parameters can be derived from these signals, (e.g., systolic, diastolic, mean and rate (frequency) values for pressures); dP/dt; contractility index CI; minimal, maximal, and mean flows, etc. During data acquisition all acquired signals and derived parameters are stored on the hard disk and can be displayed on the screen.
Search for Product in current catalog
Item Listing Full Description Specifications Journal Articles Manuals
Item# Description
730162 HSE-HA ISOHEART W Software for Isolated Heart Studies

For local pricing, contact your nearest distributor.



Full Description Back to Top

• 16 channel data acquisition software for isolated heart experiments
• For Windows® NT, 2000, and XP
• To measure signals such as: perfusion pressure, perfusion flow, left ventricular isovolumetric pressure, aortic pressure, aortic flow, atrial pressure, atrial flow, coronary flow, length measurement, pO2, pCO2, pH, temperature, etc.
• Easy to use, reduced settings by using configuration files
• Storage of raw data with possibility for replay. Complete experiments can be replayed
• Indication of the measured signals and parameters online in numerical tabular form or graphical detail and trend windows
• Data exchange interface by converting the data into the ASCII delimited format
• Monitoring of the experimental sequence by placing event markers and concentration information
• Very easy graphical selection of specific data points by cursors for evaluation, data reduction and export
• Export of a raw data sequence into ASCII delimited format

The HSE-HA ISOHEART software for Windows can be adapted to virtually any experimental investigation of isolated hearts (according to Langendorff or Working Heart). Acquisition can cover signals such as perfusion pressure, perfusion flow, left ventricular pressure, aortic pressure, aortic flow, atrial pressure, atrial flow, coronary flow, segment length or wall thickness measurement, pO2, pCO2, pH, temperature, etc. Various parameters can be derived from these signals, (e.g., systolic, diastolic, mean and rate (frequency) values for pressures); dP/dt; contractility index CI; minimal, maximal, and mean flows, etc. During data acquisition all acquired signals and derived parameters are stored on the hard disk and can be displayed on the screen.
The HSE-HA ISOHEART software is available in a basic version which includes the minimal necessary algorithms. It can be upgraded to a more complex system including all the available algorithms. The configuration of the system is defined in configuration files to reduce the amount of settings necessary and to ensure a stable and secure system. The user has only to calibrate the signals and to fix the graphics scaling. All the hardware definitions and the algorithms used are defined in the configuration files. This reduces the amount of information necessary in the SOP's and the possibilities of wrong settings. The configuration files can of course be changed and the software can be used in combination with a set of different configuration files to match the different experiments. ISOHEART is a menu-controlled software and employs special algorithms to calculate the standard parameters.

The HSE-HA ISOHEART W software has a maximum of 16 channels, i.e. up to 16 different raw signals can be handled. The assignment of the signals to the individual channels is determined in the configuration files. The sample rate, the type of signals and the algorithm used for analysis are also defined in the configuration file. The arrangement of the graphic detail (raw signals) and trend (calculated parameters) is defined in the menu. The user has only to set up which of the available signals he wants to acquire and display, which of the possible parameters he wants to evaluate and display; to enter the experimental protocol and finally to calibrate before he starts the data acquisition.
HSE-HA Data Acquisition Hardware for ISOHEART Software is available in three versions:
• PLUGSYS Version BS4 73-0161
This version consists of the PCI A/D board DT301 and the cable for connecting to a DIM Data Interface Module installed in the PLUGSYS basic system case, see page I28.
• Stand Alone Version BS4 73-0235
This version consists of the PCI A/D board DT301 and a BNC input box where signals from external amplifiers can be connected.
• Stand Alone USB Version BS4 73-3330
Hardware Requirements for ISOHEART:
Both the PLUGSYS and Stand Alone Versions require the following computer hardware:
Computer Pentium PC at least 500 MHz with one free PCI-slot,
RAM 128 MB of RAM
Operating System Windows 2000/XP or Windows NT
Hard Disk Space With at least 3.2 GB
Floppy Drive 1.44 MB
CD-ROM Drive Required
Monitor 17-19”
Backup Media MO drive, CD recorder or ZIP drive
Commonly Used Signals for Langendorff Preparation are:
LVP isovolumetric LVP or contraction force
PP perfusion pressure
CF coronary flow
WT wall thickness or left ventricle diameter
EG electrogram
pO2a /e oxygen partial pressure in the affluent / effluent
pH pH in the effluent
Commonly Used Signals for Working Heart Preparation are:
PrP preload pressure
AoP aortic pressure (afterload)
LVP left Ventricular Pressure, measured with tip catheter
AF aortic flow
CO cardiac output (flow into left atrium)
WT wall thickness or left ventricle diameter
EG electrogram
pO2a / e oxygen partial pressure in the affluent / effluent
pH pH in the effluent
It is also possible to acquire other signals (e.g., temperature);
maximum is 16 signals.
Standard ISOHEART Software is able to Calculate Following Parameters Online:
From LVP signal: LVPsys, LVPdia, LVPEDP, dLVP/dtmin, dLVP/dtmax, heart rate, mean pressure
From all pressures: systolic, diastolic and mean pressure
From all flows: mean, maximum and minimum flow
From distance: maximum, minimum and amplitude (max - min)
From electrogram: heart rate
From pO2, pCO2 and pH: mean value
For Specific Applications, Software Modules with More Parameters are available:
Advanced LVP: Tau, Time to Peak, Relaxation Time, Contractility Index CI=dp/dtmax/P, Ejection Time
Advanced flow: End Systolic Flow ESFL, End Diastolic Flow EDFL
MAP module: Max, Min, Plateau, Amp, Rate, ±dv/dt, duration at 10% of monophasic action potentials
Dimension module: end-systolic length ESL, end-diastolic length EDL, +dL/dt, -dL/dt
Software Options for Controlling External Devices:
Control of programmable stimulator PSM
Control of pretention using electrical controlled verniers
Triggering of an external stimulator


Specifications Back to Top

Specifications730162
Channels16
Computer RequirementsPC Pentium, at least 500 MHz with one free PCI-slot
RAM Requirements128 MB or better 256 Mbytes
Operating System RequirementsWindows 2000/XP or Windows NT
Hard Disk Space RequirementsAt least 3.2 GB
Floppy Drive Requirements1.44 MB
CD-ROM DriveRequired
Monitor Requirements17-19 in
Backup Media RequirementsCD recorder (burner)

Back to Top



Journal Articles Back to Top

Displaying 1 to 6 of 6results for ISOHEART® Isolated Heart Data Acquisition Software  

Score

Document

Description

100% Login to view HS15 isolated heart app.pdf
[632 KB]
Isolated Heart Apparatus use in Myoglobin facilitating oxygen diffusion
30% Login to view HS15 Myoglobin facilitates oxygen diffusion.pdf
[631 KB]
Isolated Heart Apparatus use in Myoglobin facilitating oxygen diffusion
22% Login to view VT01 2,3-Butanedione Monoxime Cardioplegia Advantages Over Hyperkalemia in Blood-Perfused Isolated Hearts.pdf
[199 KB]
2,3-Butanedione Monoxime Cardioplegia: Advantages Over Hyperkalemia in Blood-Perfused Isolated Hearts
13% Login to view VT35 mri35.pdf
[192 KB]
Animal Respirator use in finding Anesthetic inhibition in ischemic and nonischemic murine heart
10% Login to view HS08 pressure transducer.pdf
[46 KB]
Pressure Transducer use in finding blood pressure and heart rate spectral changes
10% Login to view PP56 Pump.pdf
[138 KB]
Reduced NO enhances the central gain of cardiac sympathetic afferent reflex in dogs with heart failure
   

Back to Top



Manuals Back to Top

Displaying 1 to 2 of 2results for ISOHEART® Isolated Heart Data Acquisition Software  

Score

Document

Description

100% Login to view IH-SR Brochure.pdf
[7 MB]
Isolated Heart Perfusion System for Small Rodents IHSR IH-SR
56% Login to view VT0168 1.PDF
[229 KB]
2,3-Butanedione Monoxime Cardioplegia: Advantages Over Hyperkalemia in Blood-Perfused Isolated Hearts
   

Back to Top

Breakthrough Products for Regenerative Medicine
2011 Regenerative Medicine Brochure
100's of Innovative products developed with leading scientists & surgeons!
  • Injection & Perfusion
  • Bioreactors
  • Biosensing
  • Total Solutions
  • Total Support


Announcing the new
PHD ULTRA™ Syringe Pumps

Click here for more information about PHD ULTRA™ Syringe Pumps and to download a brochure.

  • Patent pending mechanical design provides highest accuracy/precision & smoothest flow
  • Easy operation with advanced touch screen
  • Advanced EZ PRO™ software for PC functions without a PC.


Sign-up for a FREE Full Line Bioresearch Catalog
CLICK HERE!

  • Over 11,000 specialty products to enhance your bioresearch
  • Enhanced solutions for small animal research
  • 100's of pages of specialized information on instrumentation, applications, uses of products

 

Products on this website are for Research Use Only. Not for use in humans unless
proper investigational device regulations have been followed.


Privacy Policy   |   Terms and Conditions   
Copyright© Harvard Apparatus Ltd. - All rights reserved.
(44) 1223-423723
Website-related comments or concerns can be emailed to our webmaster.

Anesthesia Equipment Animal Handling Products Behavior Research Products Biological Measurement Products Cardiovascular Products Cell Biology Products Microincubation / Microinjectors CPK® Atomic Models Delivery & Sampling Products Dialysis / Sample Prep / SPE Electroporation / Transfection Electrophysiology Products General Laboratory Products Homeothermic/Temperature Control Isolated Organ & Isolated Tissue Molecular Biology Products Neuroscience Products Non-Invasive Blood Pressure Physiology Products Respiratory Products Stereotaxic Instruments Surgical Equipment Surgical Instruments Syringe Pumps/Peristaltic Pumps Tubing & Connectors Ventilators