Home Physiology Products HSE-HA Data Acquisition Software HAEMODYN® Cardiovascular Data Acquisition Software


Larger Views

 

HAEMODYN® Cardiovascular Data Acquisition Software

The HSE-HA HAEMODYN software can be adapted to virtually any experimental investigation for haemodynamic experiments. Acquisition can cover signals such as left ventricular pressure, aortic pressure, aortic flow, atrial pressure, atrial flow, coronary flow, segment length and wall thickness measurement, pO2, pCO2, pH, temperature, etc. Various parameters can be derived from these signals, e.g. systolic, diastolic, mean and rate (frequency) values for pressures, dp/dt, contractility index CI, minimal, maximal, and mean flows, etc. During data acquisition, all acquired signals and derived parameters are stored on the hard disc and can be displayed on the screen.
Search for Product in current catalog
Item Listing Full Description Specifications Journal Articles Manuals
Item# Description
731690 HSE-HA HAEMODYN W Software for Haemodynamic Studies

For local pricing, contact your nearest distributor.



Full Description Back to Top

• 16-channel data acquisition software for haemodynamic experiments
• For Windows® NT, 2000, and XP
• To measure signals such as left ventricular pressure, aortic pressure, aortic flow, atrial pressure, atrial flow, coronary flow, length measurement, pO2, pCO2, pH, temperature, etc.
• Easy to use, reduced settings by using configuration files
• Storage of raw data with possibility for replay — complete experiments can be replayed
• Indication of the measured signals and parameters online in numerical tabular form or graphical detail and trend windows
• Allows data exchange interface by converting the data into the ASCII delimited format
• Monitors the experimental sequence by placing event markers and concentration information
• Very easy graphical selection of specific data points by cursors for evaluation, data reduction and export
• Export of a raw data sequence into ASCII delimited format

The HSE-HA HAEMODYN software can be adapted to virtually any experimental investigation for haemodynamic experiments. Acquisition can cover signals such as left ventricular pressure, aortic pressure, aortic flow, atrial pressure, atrial flow, coronary flow, segment length and wall thickness measurement, pO2, pCO2, pH, temperature, etc. Various parameters can be derived from these signals, e.g. systolic, diastolic, mean and rate (frequency) values for pressures, dp/dt, contractility index CI, minimal, maximal, and mean flows, etc. During data acquisition, all acquired signals and derived parameters are stored on the hard disc and can be displayed on the screen.

The HSE-HA HAEMODYN software is available in a basic version which includes the minimal necessary algorithms that can be upgraded to a more complex system including all the available algorithms. The configuration of the system is defined in configuration files to reduce the amount of settings necessary and to ensure a stable and secure system. The user only needs to calibrate the signals and fix the graphics scaling. All the hardware definitions and algorithms used are defined in the configuration files. This reduces the amount of information necessary in the SOP's and the possibility of wrong settings. The configuration files can be changed and the software used in combination with a set of different configuration files to match the different experiments.

HAEMODYN is a menu-controlled software and employs special algorithms to calculate the standard haemodynamic parameters.

The HSE-HA HAEMODYN software has a maximum of 16 channels, i.e. up to 16 different raw signals can be handled. The assignment of the signals to the individual channels is determined in the configuration files. The sample rate, the type of signals and the algorithm used for analysis are also defined in the configuration file. The arrangement of the graphic detail (raw signals) and trend (calculated parameters) is defined in the menu. The user has only to set up which of the available signals he wants to acquire and display, which of the possible parameters he wants to evaluate and display, enter the experimental protocol, and finally calibrate before he starts the data acquisition.

The HSE-HA Data Acquisition Hardware for HAEMODYN W software is available in three versions:

• PLUGSYS Version 73-0161

This version consists of the PCI A/D board DT301 and the cable for connecting to a DIM Data Interface Module installed in the PLUGSYS basic system case.

• Stand Alone Version 73-0235

This version consists of the PCI A/D board DT301 and a BNC input box where signals from external amplifiers can be connected.

• Stand Alone USB Version 73-3330

Hardware requirements for HAEMODYN:

Both the PLUGSYS and stand alone versions require the following computer hardware:
Computer Pentium PC at least 500 MHz with one free PCI-slot,
RAM 128 MB of RAM
Operating System Windows 2000/XP or Windows NT
Hard Disk Space With at least 3.2 GB
Floppy Drive 1.44 MB
CD-ROM Drive Required
Monitor 17-19 in
Backup Media MO drive, CD recorder or ZIP drive

Commonly used signals on haemodynamic experiments are:
• LVP - Left Ventricular Pressure
• AP - Arterial Pressure
• VP - Venous Pressure
• CF - Coronary Flow
• AF - Arterial Flow
• WT - Wall Thickness or Left Ventricle Diameter
• ECG - Electrocardiogram
• pO2 - Oxygen Partial Pressure
• pCO2 - Carbon Dioxide Partial Pressure pH

It is also possible to acquire other signals such as temperature.
The maximum number of signals is 16.
The basic version of HAEMODYN calculates the following parameters online:
• From LVP Signal - LVPsys, LVPdia, LVPEDP, dP/dtmin, dP/dtmax, Heart Rate, Mean Pressure
• From All Pressures - Systolic, Diastolic and Mean Pressure, Heart Rate
• From All Flows - Mean, Max. and Min. Flow
• From Distance - Max., Min. and Amplitude (Max-Min)
• From Electrogram - Only the Heart Rate
• From pO2 Signals - Mean Value
• From pCO2 Signals - Mean Value
• From pH Signals - Mean Value

It is also possible to calculate specific values from these parameters by writing a formula (e.g., the ratio of dP/dtmin / dP/dtmax or LVPEDP / heart weight, etc.).

Optional software modules are available for:
• LVP Advanced - Tau, Time to Peak (Contractility Time), Relaxation Time and Contractility Index CI = dP/dtmax / P
• Flow Advanced - Endsystolic Flow, Enddiastolic Flow
• Respiration Module - Respiratory Rate, Max. Inspiratory Flow, Max. Expiratory Flow, Tidal Volume
• MAP Module - Max, Min, Plateau, Amp, Rate, +dv/dt, duration at 10% of MAP
• Dimensions Module - End-systolic length, end-diastolic length, +dL/dt, - dL/dt

Specific parameters which are not mentioned in this list are available by special order. Please call Harvard Apparatus Technical Service for more details.


Specifications Back to Top

Specifications731690
Channels16
Computer RequirementsPC Pentium, at least 500 MHz with one free PCI-slot
RAM Requirements128 MB or better 256 Mbytes
Operating System RequirementsWindows 2000/XP or Windows NT
Hard Disk Space RequirementsAt least 3.2 GB
Floppy Drive Requirements1.44 MB
CD-ROM DriveRequired
Monitor Requirements17-19 in
Backup Media RequirementsCD recorder (burner)

Back to Top



Journal Articles Back to Top

Displaying 1 to 5 of 5results for HAEMODYN® Cardiovascular Data Acquisition Software  

Score

Document

Description

100% Login to view HS20 Nitric Oxide prevents cardiovascular disease.pdf
[682 KB]
pq210011609p
76% Login to view HS20 Mini Ventilator.pdf
[681 KB]
Mini Ventilator used in Nitric oxide prevention of cardiovascular disease
72% Login to view PP102 blood pumpilliac.pdf
[185 KB]
Cardiovascular Pump use in finding Impact of Unilateral Common lliac Vein Occlusion
60% Login to view PP63 Model 974A Pump.pdf
[169 KB]
Differential Involvement of NMDA, AMPA/Kainate, and Dopamine Receptors
28% Login to view PP102 Impact of Unilateral Common Iliac Vein Occlusion on Trapping Efficacy of the Greenfiled Filter.pdf
[184 KB]
Cardiovascular Pump use in finding Impact of Unilateral Common lliac Vein Occlusion
   

Back to Top



Manuals Back to Top

Displaying 1 to 1 of 1result for HAEMODYN® Cardiovascular Data Acquisition Software  

Score

Document

Description

100% Login to view IH-SR Brochure.pdf
[7 MB]
Isolated Heart Perfusion System for Small Rodents IHSR IH-SR
   

Back to Top

Breakthrough Products for Regenerative Medicine
2011 Regenerative Medicine Brochure
100's of Innovative products developed with leading scientists & surgeons!
  • Injection & Perfusion
  • Bioreactors
  • Biosensing
  • Total Solutions
  • Total Support


Announcing the new
PHD ULTRA™ Syringe Pumps

Click here for more information about PHD ULTRA™ Syringe Pumps and to download a brochure.

  • Patent pending mechanical design provides highest accuracy/precision & smoothest flow
  • Easy operation with advanced touch screen
  • Advanced EZ PRO™ software for PC functions without a PC.


Sign-up for a FREE Full Line Bioresearch Catalog
CLICK HERE!

  • Over 11,000 specialty products to enhance your bioresearch
  • Enhanced solutions for small animal research
  • 100's of pages of specialized information on instrumentation, applications, uses of products

 

Products on this website are for Research Use Only. Not for use in humans unless
proper investigational device regulations have been followed.


Privacy Policy   |   Terms and Conditions   
Copyright© Harvard Apparatus Ltd. - All rights reserved.
(44) 1223-423723
Website-related comments or concerns can be emailed to our webmaster.

Anesthesia Equipment Animal Handling Products Behavior Research Products Biological Measurement Products Cardiovascular Products Cell Biology Products Microincubation / Microinjectors CPK® Atomic Models Delivery & Sampling Products Dialysis / Sample Prep / SPE Electroporation / Transfection Electrophysiology Products General Laboratory Products Homeothermic/Temperature Control Isolated Organ & Isolated Tissue Molecular Biology Products Neuroscience Products Non-Invasive Blood Pressure Physiology Products Respiratory Products Stereotaxic Instruments Surgical Equipment Surgical Instruments Syringe Pumps/Peristaltic Pumps Tubing & Connectors Ventilators