Welcome to Harvard Apparatus UK! Login / Register
Search

Search for these keywords
Home Catalogs Online Technical Resources My Account
Advanced Search   
Products by Category

Featured Products
Warner Cell Electrophysiology & Cell Biology Research
Hugo Sachs Elektronic Isolated Organ and Tissue Systems
BTX Electroporation and Electrofusion Products
Panlab Behavior Research Products
Hoefer Electrophoresis Products
Coulbourn Instruments
Clark Glass Products
Navicyte Ussing/Diffusion Chambers
CMA
Harvard Apparatus
 

Home Meander Fusion Chamber


Larger Views

 

Meander Fusion Chamber

The BTX Meander Fusion Chamber is a novel microslide design which is specifically used for electro cell fusion. The Meander Fusion Chamber generates a divergent field and is used for fusion of mammalian cells, plant, yeast, fungi and microorganisms.
Search for Product in current catalog
Item Listing Full Description Specifications Journal Articles Manuals
Item# Description
450107 Meander Fusion Chamber, 0.2 mm Gap, pkg. of 4 (Model 454) Requires 45-0201 Square Post Cables and 45-0210 Coaxial Banana Plug Cable

For local pricing, contact your nearest distributor.



Full Description Back to Top

Applications:
• Cell Fusion
• Hybridoma Production
• Plant Protoplast Fusion

The BTX Meander Fusion Chamber is a novel microslide design which is specifically used for electro cell fusion. The Meander Fusion Chamber generates a divergent field and is used for fusion of mammalian cells, plant, yeast, fungi and microorganisms.
This specialty electrode is constructed of a conductive metal alloy. It has two primary bars that are connected by many tiny fingerlike projections. These projections are spaced 0.2 mm apart. This electrode is mounted on a glass slide. It is designed for direct viewing of dimmer formation during alignment while under a microscope.


Specifications Back to Top

Specifications450107
Model454
Electrode Shape/MaterialConductive metal alloy
ApplicationsCell Fusion, Hybridoma Production, Plant Protoplast Fusion
Generator CompatibilityECM 2001
Voltage RangeAC 16 V (0 – peak); DC 480 V
Gap Size0.2 mm

Back to Top



Journal Articles Back to Top

Displaying 1 to 10 of 12results for Meander Fusion Chamber   Page 1  2 

Score

Document

Description

100% Login to view PP05 Syringe MS Pump.pdf
[201 KB]
Electrospray Ionization Mass Spectrometric Anlyses of Phospholipids from Rat and Human Pancreatic Islets and Subcellular Membranes with us of Harvard Syringe Pump
67% Login to view OT01 Chambers.pdf
[963 KB]
Primary Uroepithelial Cultures
67% Login to view Primary Uroepithelial Cultures.pdf
[971 KB]
Primary Uroepithelial Cultures
66% Login to view WR16 RC25.pdf
[275 KB]
Recording Chamber use in finding Hypoxic Augmentation of Fast-Inactivating and Persistent Sodium Currents in Rat Caudal Hypothalamic Neurons
60% Login to view Hypoxic Augmentation of Fast-Inactivating and Persistent Sodium.pdf
[281 KB]
Recording Chamber use in finding Hypoxic Augmentation of Fast-Inactivating and Persistent Sodium Currents in Rat Caudal Hypothalamic Neurons
53% Login to view electroprep3.pdf
[375 KB]
Binding of pregnancy-specific glycoprotein 17 to CD9 on macrophages induces secretion of IL-10, IL-6, PGE2,and TGF-B 1
47% Login to view MC01 Impaired Stratum Corneum Hydration in Mice Lacking Epidermal Water Channel Aquaporin-3.pdf
[339 KB]
Metabolic Cages use in finding Impaired Stratum Corneum Hydration in Mice Lacking Epidermal Water Channel Aquaporin-3
33% Login to view electroprep1.pdf
[232 KB]
Isolation and purification of two major serum amyloid A isotypes SAA1 and SAA2 from the acute phase plasma of mice
33% Login to view macro fast dispo dial.pdf
[241 KB]
Cisplatin delivery from poly(acrylic acid-co-methyl methacrylate) microparticles
27% Login to view flow thru dial.pdf
[387 KB]
A Novel Approach for the Extraction and Concentration of Compounds in Biological Fluids via On-Line Dialysis and Enrichment
   

Back to Top



Manuals Back to Top

Displaying 1 to 1 of 1result for Meander Fusion Chamber  

Score

Document

Description

100% Login to view Ussing Chamber Systems.pdf
[1.5 MB]
Guide to Ussing Chamber Systems
   

Back to Top

Breakthrough Products for Regenerative Medicine
2011 Regenerative Medicine Brochure
100's of Innovative products developed with leading scientists & surgeons!
  • Injection & Perfusion
  • Bioreactors
  • Biosensing
  • Total Solutions
  • Total Support


Announcing the new
PHD ULTRA™ Syringe Pumps

Click here for more information about PHD ULTRA™ Syringe Pumps and to download a brochure.

  • Patent pending mechanical design provides highest accuracy/precision & smoothest flow
  • Easy operation with advanced touch screen
  • Advanced EZ PRO™ software for PC functions without a PC.


Sign-up for a FREE Full Line Bioresearch Catalog
CLICK HERE!

  • Over 11,000 specialty products to enhance your bioresearch
  • Enhanced solutions for small animal research
  • 100's of pages of specialized information on instrumentation, applications, uses of products

 

Products on this website are for Research Use Only. Not for use in humans unless
proper investigational device regulations have been followed.


Privacy Policy   |   Terms and Conditions   
Copyright© Harvard Apparatus Ltd. - All rights reserved.
(44) 1223-423723
Website-related comments or concerns can be emailed to our webmaster.

Anesthesia Equipment Animal Handling Products Behavior Research Products Biological Measurement Products Cardiovascular Products Cell Biology Products Microincubation / Microinjectors CPK® Atomic Models Delivery & Sampling Products Dialysis / Sample Prep / SPE Electroporation / Transfection Electrophysiology Products General Laboratory Products Homeothermic/Temperature Control Isolated Organ & Isolated Tissue Molecular Biology Products Neuroscience Products Non-Invasive Blood Pressure Physiology Products Respiratory Products Stereotaxic Instruments Surgical Equipment Surgical Instruments Syringe Pumps/Peristaltic Pumps Tubing & Connectors Ventilators