Home Rodent Anesthesia Circuit Mask


Larger Views

 

Rodent Anesthesia Circuit Mask

Developed in conjunction with leading research facilities, the Rodent circuit is the most effective, user-friendly, mask for rodents. Available with 3 different size diaphragms, the mask easily fits most rodents. With the use of a C-Pram circuit shown below, the mask is designed to deliver and evacuate the gas through one tube.
Search for Product in current catalog
Item Listing Full Description Specifications Journal Articles Manuals
Item# Description
723026 Circuit Set, Rodent (hose, mask and medium diaphragm)
723027 Mask, Rodent (no diaphragm)
723028 Rodent Mask Diaphragm Small (7/16 in DIA)
723029 Rodent Mask Diaphragm Medium (9/16 in DIA)
723030 Rodent Mask Diaphragm Large (3/4 in) DIA)

For local pricing, contact your nearest distributor.



Full Description Back to Top

• Unique circuit designed specifically for rodent anesthesia
• Best suited for use with Multi-station Research Anesthesia System, see page F19
• Will work with any non-rebreathing anesthesia machine

Developed in conjunction with leading research facilities, the Rodent circuit is the most effective, user-friendly, mask for rodents. Available with 3 different size diaphragms, the mask easily fits most rodents. With the use of a C-Pram circuit shown below, the mask is designed to deliver and evacuate the gas through one tube. Traditionally, the open mask system has caused problems because of the contamination of waste gas to the staff and the patient rebreathing CO2. These problems are avoided with the Rodent circuit and mask design. When combined with in-house suction or the Lab Animal Evacuation System or F/Air canister, see page F19, there is minimal risk of untoward anesthetic agent exposure for the researcher. Inlet tubing: 6.25 mm (0.25 in) ID, silicone tubing. Outlet from rodent circuit is a 22 mm (0.866 in) respiratory fitting. Respiratory Adapters are available to connect the rodent circuit outlet to tubing of various sizes from 6 to 15 mm ID, see page F22.


Specifications Back to Top

Specifications723026723027723028723029723030
Diameter English9/16 in*na in7/16 in9/16 in3/4 in
MaterialSilicone TubingSilicone TubingSilicone TubingSilicone TubingSilicone Tubing
Inlet Tubing ID Metric6.25 mm6.25 mm6.25 mm6.25 mm*na mm
Inlet Tubing ID English0.25 in0.25 in0.25 in0.25 in*na in
Outlet Respiratory Fitting Metric22 mm22 mm22 mm22 mm*na mm
Outlet Respiratory Fitting English0.866 in0.866 in0.866 in0.866 in*na in

Back to Top



Journal Articles Back to Top

Displaying 1 to 10 of 10results for Rodent Anesthesia Circuit Mask  

Score

Document

Description

100% Login to view VT14 Rodent Ventilator.pdf
[440 KB]
PDMI-2 Microincubator use in Airway surface liquid pH in well-differentiated airway epithelial cell cultures and mouse trachea
60% Login to view VT03 Rodent Ventilator use in finding Reduced PO2 and Adenosine Formation Preserve Arteriolar Nitric Oxide.pdf
[283 KB]
Rodent Ventilator use in finding Ventilatory and metabolic responses to hypoxia in the smallest simian primate, the pygmy marmoset
50% Login to view VT22 Rodent Ventilator.pdf
[194 KB]
Rodent Ventilator use in finding arterior wall PO2 and nitric oxide release during sympathetic vasoconstriction in the rat intestine
49% Login to view VT04 683.pdf
[298 KB]
Rodent Ventilator use in finding Ventilatory and metabolic responses to hypoxia in the smallest simian primate, the pygmy marmoset
48% Login to view VT30 Rodent Ventilator use in Antisense Knockdown of the Gial Glutamate Transporter GLT-1.pdf
[366 KB]
Rodent Ventilator use in Antisense Knockdown of the Gial Glutamate Transporter GLT-1
47% Login to view VT12 Small rodent ventilator use in finding chronic measurement of cardiac output in conscious mice.pdf
[184 KB]
Small rodent ventilator use in finding chronic measurement of cardiac output in conscious mice
39% Login to view VT12 mini 2002hs.pdf
[177 KB]
Small rodent ventilator use in finding chronic measurement of cardiac output in conscious mice
37% Login to view VT30 ventilator.pdf
[360 KB]
Rodent Ventilator use in Antisense Knockdown of the Gial Glutamate Transporter GLT-1
33% Login to view VT10 683 atr.pdf
[124 KB]
Rodent Resiprator use in finding Arteriolar reactivity and capillarization in chronically stimulated rat limb skeletal muscle post-MI
30% Login to view VT03 Model 683 Ventilator.pdf
[274 KB]
Rodent Ventilator use in finding Reduced PO2 and Adenosine Formation Preserve Arteriolar Nitric Oxide
   

Back to Top



Manuals Back to Top

Displaying 1 to 1 of 1result for Rodent Anesthesia Circuit Mask  

Score

Document

Description

100% Login to view Anesthesia Selection Guide.pdf
[28 KB]
BS4_F_Respiration.qxd
   

Back to Top

Breakthrough Products for Regenerative Medicine
2011 Regenerative Medicine Brochure
100's of Innovative products developed with leading scientists & surgeons!
  • Injection & Perfusion
  • Bioreactors
  • Biosensing
  • Total Solutions
  • Total Support


Announcing the new
PHD ULTRA™ Syringe Pumps

Click here for more information about PHD ULTRA™ Syringe Pumps and to download a brochure.

  • Patent pending mechanical design provides highest accuracy/precision & smoothest flow
  • Easy operation with advanced touch screen
  • Advanced EZ PRO™ software for PC functions without a PC.


Sign-up for a FREE Full Line Bioresearch Catalog
CLICK HERE!

  • Over 11,000 specialty products to enhance your bioresearch
  • Enhanced solutions for small animal research
  • 100's of pages of specialized information on instrumentation, applications, uses of products

 

Products on this website are for Research Use Only. Not for use in humans unless
proper investigational device regulations have been followed.


Privacy Policy   |   Terms and Conditions   
Copyright© Harvard Apparatus Ltd. - All rights reserved.
(44) 1223-423723
Website-related comments or concerns can be emailed to our webmaster.

Anesthesia Equipment Animal Handling Products Behavior Research Products Biological Measurement Products Cardiovascular Products Cell Biology Products Microincubation / Microinjectors CPK® Atomic Models Delivery & Sampling Products Dialysis / Sample Prep / SPE Electroporation / Transfection Electrophysiology Products General Laboratory Products Homeothermic/Temperature Control Isolated Organ & Isolated Tissue Molecular Biology Products Neuroscience Products Non-Invasive Blood Pressure Physiology Products Respiratory Products Stereotaxic Instruments Surgical Equipment Surgical Instruments Syringe Pumps/Peristaltic Pumps Tubing & Connectors Ventilators