Home Isolated Perfused Rodent Mesenteric Bed System


Larger Views

 

Isolated Perfused Rodent Mesenteric Bed System

The rat hind leg and the rabbit ear are conventional preparations for investigating the tone of blood vessels under the effect of vasoactive substances in the peripheral vascular bed, either at constant perfusion pressure or at constant flow. Both set-ups suffer from the disadvantage that the measurement is affected by early edema formation. In the rat, the mesenteric circulation receives approximately 20% of the cardiac output; its regulation may therefore contribute significantly to the systemic blood pressure and circulating blood volume. The presence of arterioles, i.e. the most important vessels in the regulation of vascular resistance, renders the mesenteric bed an important preparation for the study of vascular physiology, pathophysiology and pharmacology.
Search for Product in current catalog
Item Listing Full Description Journal Articles Manuals
Item# Description
739910 Isolated Rat Mesenteric Bed System

For local pricing, contact your nearest distributor.



Full Description Back to Top

• For investigating the tone of small blood vessels under the effect of vasoactive substances
• Compact arrangement
• Organ is in warm and moist environment during perfusion
• Electrical field stimulation capabilities

The rat hind leg and the rabbit ear are conventional preparations for investigating the tone of blood vessels under the effect of vasoactive substances in the peripheral vascular bed, either at constant perfusion pressure or at constant flow. Both set-ups suffer from the disadvantage that the measurement is affected by early edema formation. In the rat, the mesenteric circulation receives approximately 20% of the cardiac output; its regulation may therefore contribute significantly to the systemic blood pressure and circulating blood volume. The presence of arterioles, i.e. the most important vessels in the regulation of vascular resistance, renders the mesenteric bed an important preparation for the study of vascular physiology, pathophysiology and pharmacology.
The organ bath for the rat mesenteric bed consists of a moist chamber with cover, both water jacketed. The mesenteric tissue is placed into the moist chamber on a stainless steel mesh which also acts as anode during electrical stimulation. The superior mesenteric artery is cannulated (steel cannula) and perfused at constant flow (e.g. 5 ml/min) through a roller pump via a heat exchanger included in the moist chamber. The test drug is introduced through a separate roller pump or a syringe pump directly before the vascular bed preparation. The perfusion pressure is measured in a branch before the stainless steel cannula.
For electrical stimulation, the Mesenteric Bed is placed on a stainless steel grid and a metal clip is attached to the aorta section near the steel cannula.


Journal Articles Back to Top

Displaying 1 to 10 of 22results for Isolated Perfused Rodent Mesenteric Bed System   Page 1  2  3 

Score

Document

Description

100% Login to view VT22 Rodent Ventilator.pdf
[194 KB]
Rodent Ventilator use in finding arterior wall PO2 and nitric oxide release during sympathetic vasoconstriction in the rat intestine
59% Login to view VT01 2,3-Butanedione Monoxime Cardioplegia Advantages Over Hyperkalemia in Blood-Perfused Isolated Hearts.pdf
[199 KB]
2,3-Butanedione Monoxime Cardioplegia: Advantages Over Hyperkalemia in Blood-Perfused Isolated Hearts
56% Login to view HS15 isolated heart app.pdf
[632 KB]
Isolated Heart Apparatus use in Myoglobin facilitating oxygen diffusion
34% Login to view VT14 Rodent Ventilator.pdf
[440 KB]
PDMI-2 Microincubator use in Airway surface liquid pH in well-differentiated airway epithelial cell cultures and mouse trachea
32% Login to view HS14 Hyperventilation and Cytokine Release.pdf
[422 KB]
Ventilator and Amplifier use in Hyperventilation Inducing release of Cytokines from Perfused Mouse Lung
25% Login to view HS14 vent and amp.pdf
[431 KB]
Ventilator and Amplifier use in Hyperventilation Inducing release of Cytokines from Perfused Mouse Lung
24% Login to view VT30 Rodent Ventilator use in Antisense Knockdown of the Gial Glutamate Transporter GLT-1.pdf
[366 KB]
Rodent Ventilator use in Antisense Knockdown of the Gial Glutamate Transporter GLT-1
23% Login to view HS15 Myoglobin facilitates oxygen diffusion.pdf
[631 KB]
Isolated Heart Apparatus use in Myoglobin facilitating oxygen diffusion
21% Login to view PP93.pdf
[1.4 MB]
Gene transfer of dominant-negative RhoA increases outflow facility in perfused human anterior segment cultures
20% Login to view VT03 Model 683 Ventilator.pdf
[274 KB]
Rodent Ventilator use in finding Reduced PO2 and Adenosine Formation Preserve Arteriolar Nitric Oxide
   

Back to Top



Manuals Back to Top

Displaying 1 to 2 of 2results for Isolated Perfused Rodent Mesenteric Bed System  

Score

Document

Description

100% Login to view Isolated Preamplifier.pdf
[126 KB]
Isolated Preamplifier manual
90% Login to view VT0168 1.PDF
[229 KB]
2,3-Butanedione Monoxime Cardioplegia: Advantages Over Hyperkalemia in Blood-Perfused Isolated Hearts
   

Back to Top

Breakthrough Products for Regenerative Medicine
2011 Regenerative Medicine Brochure
100's of Innovative products developed with leading scientists & surgeons!
  • Injection & Perfusion
  • Bioreactors
  • Biosensing
  • Total Solutions
  • Total Support


Announcing the new
PHD ULTRA™ Syringe Pumps

Click here for more information about PHD ULTRA™ Syringe Pumps and to download a brochure.

  • Patent pending mechanical design provides highest accuracy/precision & smoothest flow
  • Easy operation with advanced touch screen
  • Advanced EZ PRO™ software for PC functions without a PC.


Sign-up for a FREE Full Line Bioresearch Catalog
CLICK HERE!

  • Over 11,000 specialty products to enhance your bioresearch
  • Enhanced solutions for small animal research
  • 100's of pages of specialized information on instrumentation, applications, uses of products

 

Products on this website are for Research Use Only. Not for use in humans unless
proper investigational device regulations have been followed.


Privacy Policy   |   Terms and Conditions   
Copyright© Harvard Apparatus Ltd. - All rights reserved.
(44) 1223-423723
Website-related comments or concerns can be emailed to our webmaster.

Anesthesia Equipment Animal Handling Products Behavior Research Products Biological Measurement Products Cardiovascular Products Cell Biology Products Microincubation / Microinjectors CPK® Atomic Models Delivery & Sampling Products Dialysis / Sample Prep / SPE Electroporation / Transfection Electrophysiology Products General Laboratory Products Homeothermic/Temperature Control Isolated Organ & Isolated Tissue Molecular Biology Products Neuroscience Products Non-Invasive Blood Pressure Physiology Products Respiratory Products Stereotaxic Instruments Surgical Equipment Surgical Instruments Syringe Pumps/Peristaltic Pumps Tubing & Connectors Ventilators