Welcome to Harvard Apparatus UK! Login / Register
Search

Search for these keywords
Home Catalogs Online Technical Resources My Account
Advanced Search   
Products by Category

Featured Products
Warner Cell Electrophysiology & Cell Biology Research
Hugo Sachs Elektronic Isolated Organ and Tissue Systems
BTX Electroporation and Electrofusion Products
Panlab Behavior Research Products
Hoefer Electrophoresis Products
Coulbourn Instruments
Clark Glass Products
Navicyte Ussing/Diffusion Chambers
CMA
Harvard Apparatus
 

Home Mayflower Horizontal Tissue Bath System


Larger Views

 

Mayflower Horizontal Tissue Bath System

The Mayflower tissue bath is a horizontal tissue chamber with an integral contraction force measurement. It is completely open at the top and has a small bath volume of 3 - 5 ml. The compact and modular construction provides ideal conditions for investigations on small muscle preparations (urethra, papillary muscle, cavernous body), vascular rings, or tracheal rings.
Search for Product in current catalog
Item Listing Full Description Journal Articles Manuals
Item# Description
739918 Mayflower Horizontal Tissue Bath System

For local pricing, contact your nearest distributor.



Full Description Back to Top

• Horizontal tissue bath for contraction measurements using a force transducer
• Can be used as a flow-through or closed-loop system
• Possibility of electrical stimulation
• Exchangeable holders depending on tissue used (for vascular or tracheal rings, for strips)

The Mayflower tissue bath is a horizontal tissue chamber with an integral contraction force measurement. It is completely open at the top and has a small bath volume of 3 - 5 ml. The compact and modular construction provides ideal conditions for investigations on small muscle preparations (urethra, papillary muscle, cavernous body), vascular rings, or tracheal rings.
The basic equipment consists of:
• Acrylate support with a movable mounting platform for preload adjustment through a micrometer screw. This platform acts as holder for the force transducer HSE-HA F-30 or F-10. The acrylate support also includes a glass heat exchanger for the pre-heating of the perfusate solution.
• The tissue chamber carved out of a rectangular acrylate block and placed on the support stand. This chamber normally includes the tissue holder, the connections for electrical stimulation electrodes, a frit for aeration and a draw-off tube with height adjustment to set the bath volume.
• A multi-channel roller pump for the perfusate circuit permits operation as recirculating or as flow-through system.
• A thermocirculator for keeping the perfusate solution at constant temperature.
The modular concept of this apparatus offers a wide range of
different arrangements to meet individual requirements regarding bath geometry, tissue holders and stimulation electrodes. The
horizontal arrangement of the tissue and the open top provide ideal conditions during preparation and experiment. The tissue bath is available as a complete set-up for 1 up to 8 channels. Two connection sockets for the stimulation electrodes are located on either side of the tissue chamber. Different types of electrodes are available. The solution flows in from a roller pump, the outflow is under suction by the same pump.


Journal Articles Back to Top

Displaying 1 to 10 of 25results for Mayflower Horizontal Tissue Bath System   Page 1  2  3 

Score

Document

Description

100% Login to view HB01 Assessment of Tissue Oxygen Tension.pdf
[270 KB]
Homeothermic Blanket Assessment of tissue oxygen tension
74% Login to view HS03F3 Potassium channal inhibition in coronary arteries.pdf
[536 KB]
Force Displacemen Transducer, 5-hydroxytryptamine is a mediator of 4-aminopyridine induced contractions in porcine and human isolated coronary arteries
62% Login to view HS19 Soluble Guanylyl Cyclase in Aging and Hypertension.pdf
[238 KB]
hy010000043p
62% Login to view HS02IS Evaluation of Skeletonized LITA.pdf
[228 KB]
Isolated Organ Set use in Intraoperative and Laboratory Evaluation of Skeletonized Versus Pedicled Internal Thoracic Artery
62% Login to view HS01 Opioids and Coronary Vascular Tone.pdf
[138 KB]
Force Transducer influence of opioids on the vascular tone of isolated porcine coronary artery segments
50% Login to view HB01 homethermic blanket.pdf
[259 KB]
Homeothermic Blanket Assessment of tissue oxygen tension
46% Login to view HS19 Organ Bath.pdf
[259 KB]
Organ Bath use in Aging and Chronic Hypertension Decrease Expression of Rat Aortic Soluble Guanylyl Cyclase
43% Login to view HS09TY Sarcoplasmic Reticulum Ca2+ Uptake and release.pdf
[1.3 MB]
Sarcoplasmic Reticulim Ca2+ Uptake and Release
35% Login to view WR04PL 1.PDF
[495 KB]
Two Distinct Ca2+ - Dependent Signaling Pathways regulate the Motor Output of Cochlear Outer Hair Cells with Pneumatic Injection System
33% Login to view PP124.pdf
[441 KB]
Imaging cocaine-induced changes in the mesocorticolimbic dopaminergic system of conscious rats
   

Back to Top



Manuals Back to Top

Displaying 1 to 1 of 1result for Mayflower Horizontal Tissue Bath System  

Score

Document

Description

100% Login to view Perfusion Tissue Systems Guide.pdf
[105 KB]
New BS4_K_Isolated Organ.qxd
   

Back to Top

Breakthrough Products for Regenerative Medicine
2011 Regenerative Medicine Brochure
100's of Innovative products developed with leading scientists & surgeons!
  • Injection & Perfusion
  • Bioreactors
  • Biosensing
  • Total Solutions
  • Total Support


Announcing the new
PHD ULTRA™ Syringe Pumps

Click here for more information about PHD ULTRA™ Syringe Pumps and to download a brochure.

  • Patent pending mechanical design provides highest accuracy/precision & smoothest flow
  • Easy operation with advanced touch screen
  • Advanced EZ PRO™ software for PC functions without a PC.


Sign-up for a FREE Full Line Bioresearch Catalog
CLICK HERE!

  • Over 11,000 specialty products to enhance your bioresearch
  • Enhanced solutions for small animal research
  • 100's of pages of specialized information on instrumentation, applications, uses of products

 

Products on this website are for Research Use Only. Not for use in humans unless
proper investigational device regulations have been followed.


Privacy Policy   |   Terms and Conditions   
Copyright© Harvard Apparatus Ltd. - All rights reserved.
(44) 1223-423723
Website-related comments or concerns can be emailed to our webmaster.

Anesthesia Equipment Animal Handling Products Behavior Research Products Biological Measurement Products Cardiovascular Products Cell Biology Products Microincubation / Microinjectors CPK® Atomic Models Delivery & Sampling Products Dialysis / Sample Prep / SPE Electroporation / Transfection Electrophysiology Products General Laboratory Products Homeothermic/Temperature Control Isolated Organ & Isolated Tissue Molecular Biology Products Neuroscience Products Non-Invasive Blood Pressure Physiology Products Respiratory Products Stereotaxic Instruments Surgical Equipment Surgical Instruments Syringe Pumps/Peristaltic Pumps Tubing & Connectors Ventilators