Welcome to Harvard Apparatus UK! Login / Register
Search

Search for these keywords
Home Catalogs Online Technical Resources My Account
Advanced Search   
Products by Category

Featured Products
Warner Cell Electrophysiology & Cell Biology Research
Hugo Sachs Elektronic Isolated Organ and Tissue Systems
BTX Electroporation and Electrofusion Products
Panlab Behavior Research Products
Hoefer Electrophoresis Products
Coulbourn Instruments
Clark Glass Products
Navicyte Ussing/Diffusion Chambers
CMA
Harvard Apparatus
 

Home Ussing Chambers


Larger Views

 

Ussing Chambers

U9500 series Ussing chambers are machined from solid clear acrylic rod into two symmetric halves. Each half has locating holes on the outside end for mounting onto the support bracket. One face has sharp stainless-steel pins which mate with holes in the corresponding face for puncturing and positioning the epithelium membrane. Luer-tapered fittings are pre-installed in the vertical and horizontal ports for circulation of buffer solutions and for making electrical I/O connections into the chamber.
Search for Product in current catalog
Item Listing Full Description Specifications Journal Articles Manuals
Item# Description
640504 Ussing Chamber, 3.8 mm diameter
640505 Ussing Chamber, 6.0 mm diameter
640506 Ussing Chamber, 9.0 mm diameter
640507 Ussing Chamber, 12.0 mm diameter
640508 Ussing Chamber, 13.5 mm diameter
640509 Slotted Chamber, 1.5 x 7.0 mm
640510 Slotted Chamber, 2.5 x 7.0 mm
640511 Slotted Chamber, 3.5 x 7.0 mm

For local pricing, contact your nearest distributor.



Full Description Back to Top


U9500 series Ussing chambers are machined from solid clear acrylic rod into two symmetric halves. Each half has locating holes on the outside end for mounting onto the support bracket. One face has sharp stainless-steel pins which mate with holes in the corresponding face for puncturing and positioning the epithelium membrane. Luer-tapered fittings are pre-installed in the vertical and horizontal ports for circulation of buffer solutions and for making electrical I/O connections into the chamber.
U9500 series Ussing chambers are available in five diameters from 3.8 mm to 13.5 mm and three slotted sizes to accommodate a variety of tissue sizes. The choice of chamber depends on the species and epithelia under study. The specified diameter designates the main chamber opening in which the buffer makes contact with the membrane.


Specifications Back to Top

Specifications640504640505640506640507640508640509640510640511
ModelU9504U9506U9509U9512U9513U9504SP-1U9504SP-2U9504SP-3
Diameter3.8 mm6.0 mm9.0 mm12.0 mm13.5 mm   
Dimension     1.5 x 7.0mm2.5 x 7.0 mm3.5 x 7.0 mm
*NoteChambers with drains are available, please call our technical support for more information.Chambers with drains are available, please call our technical support for more information.Chambers with drains are available, please call our technical support for more information.Chambers with drains are available, please call our technical support for more information.Chambers with drains are available, please call our technical support for more information.Chambers with drains are available, please call our technical support for more information.Chambers with drains are available, please call our technical support for more information.Chambers with drains are available, please call our technical support for more information.

Back to Top



Journal Articles Back to Top

Displaying 1 to 10 of 10results for Ussing Chambers  

Score

Document

Description

100% Login to view OT01 Chambers.pdf
[963 KB]
Primary Uroepithelial Cultures
100% Login to view Primary Uroepithelial Cultures.pdf
[971 KB]
Primary Uroepithelial Cultures
68% Login to view PP35 Peristaltic Pump.pdf
[381 KB]
Peristaltic pump use in finding Improvements to parallel plate flow chambers to reduce reagent and cellular requirements
29% Login to view 96well eq dialplate2.pdf
[40 KB]
In Vitro Assessment of Plasma Protein Binding and Metabolic Stability of PTK 0796 (BAY 73-6994)
24% Login to view 96well eq dialplate4.pdf
[1.9 MB]
Kringle 5 of Human Plasminogen Induces Apoptosis of Endothelial and Tumor Cells through Surface-Expressed Glucose-Regulated Protein 78
24% Login to view dispo eq dial1.pdf
[1.4 MB]
Three-dimensional Structure of Guanylyl Cyclase Activating Protein-2, a Calcium-sensitive Modulator of Photore
24% Login to view dispo eq dial3.pdf
[868 KB]
An mRNA structure that controls gene expression by binding S-adenosylmethionine
24% Login to view micro eq dial2.pdf
[1.1 MB]
Control of electrostatic interactions between F-actin and genetically modified lysozyme in aqueous media
24% Login to view 96well eq dialplate5.pdf
[317 KB]
Interspecies differences in plasma protein binding of MS-275, a novel histone deacetylase inhibitor
20% Login to view micro eq dial1.pdf
[354 KB]
Equilibrium Dialyzer for use in finding Differential ATP binding and Intrinsic ATP Hydrolysis
   

Back to Top



Manuals Back to Top

Displaying 1 to 1 of 1result for Ussing Chambers  

Score

Document

Description

100% Login to view Ussing Chamber Systems.pdf
[1.5 MB]
Guide to Ussing Chamber Systems
   

Back to Top

Breakthrough Products for Regenerative Medicine
2011 Regenerative Medicine Brochure
100's of Innovative products developed with leading scientists & surgeons!
  • Injection & Perfusion
  • Bioreactors
  • Biosensing
  • Total Solutions
  • Total Support


Announcing the new
PHD ULTRA™ Syringe Pumps

Click here for more information about PHD ULTRA™ Syringe Pumps and to download a brochure.

  • Patent pending mechanical design provides highest accuracy/precision & smoothest flow
  • Easy operation with advanced touch screen
  • Advanced EZ PRO™ software for PC functions without a PC.


Sign-up for a FREE Full Line Bioresearch Catalog
CLICK HERE!

  • Over 11,000 specialty products to enhance your bioresearch
  • Enhanced solutions for small animal research
  • 100's of pages of specialized information on instrumentation, applications, uses of products

 

Products on this website are for Research Use Only. Not for use in humans unless
proper investigational device regulations have been followed.


Privacy Policy   |   Terms and Conditions   
Copyright© Harvard Apparatus Ltd. - All rights reserved.
(44) 1223-423723
Website-related comments or concerns can be emailed to our webmaster.

Anesthesia Equipment Animal Handling Products Behavior Research Products Biological Measurement Products Cardiovascular Products Cell Biology Products Microincubation / Microinjectors CPK® Atomic Models Delivery & Sampling Products Dialysis / Sample Prep / SPE Electroporation / Transfection Electrophysiology Products General Laboratory Products Homeothermic/Temperature Control Isolated Organ & Isolated Tissue Molecular Biology Products Neuroscience Products Non-Invasive Blood Pressure Physiology Products Respiratory Products Stereotaxic Instruments Surgical Equipment Surgical Instruments Syringe Pumps/Peristaltic Pumps Tubing & Connectors Ventilators