Home Inserts for P2400 Low Volume EasyMount Diffusion Chambers


Larger Views

 

Inserts for P2400 Low Volume EasyMount Diffusion Chambers

The EasyMount series of vertical diffusion chamber systems consists of two individual diffusion (Ussing) chambers, a heating block for temperature control, needle valves for adjustment of gas flow for oxygenation and gas lift stirring and Ag/AgCl voltage and current electrodes for measuring transepithelial voltage and for passing current.
Search for Product in current catalog
Item Listing Full Description Specifications Journal Articles Manuals
Item# Description
690969 Insert for EasyMount Diffusion Chamber - for Mouse Intestine
690970 Insert for EasyMount Diffusion Chamber - for Rat and Larger Animal Intestines
690971 Insert for EasyMount Diffusion Chamber - for Mouse Trachea, Similar Tissues
690972 Insert for EasyMount Diffusion Chamber - for Small Tissues (I.e., Biopsies)
690973 Insert for EasyMount Diffusion Chamber - with Mounting Pins
690974 Insert for EasyMount Diffusion Chamber - with Mounting Pins
690975 Insert for EasyMount Diffusion Chamber - with Mounting Pins
690976 Insert for EasyMount Diffusion Chamber - with Mounting Pins

For local pricing, contact your nearest distributor.



Full Description Back to Top

• Ideal for high-throughput applications
• Dual vertical diffusion chamber configuration
• Tissue and cell culture inserts for all applications
• Built-in temperature control block
• Needle valve gas flow control manifold
• Ag/AgCl voltage and current electrodes
• Series connection for multiple systems

The EasyMount series of vertical diffusion chamber systems consists of two individual diffusion (Ussing) chambers, a heating block for temperature control, needle valves for adjustment of gas flow for oxygenation and gas lift stirring and Ag/AgCl voltage and current electrodes for measuring transepithelial voltage and for passing current.
All EasyMount chambers (series P2250, P2300, P2400 and P2500) use the same stand and electrodes. Each has one or more application specific ‘sliders’ designed to hold a wide variety of tissues and cell culture inserts, see chart below. Tissues are placed in the chamber simply by loosening a thumbscrew, inserting the slider holding the tissue into the space between the chamber halves, and retightening the thumbscrew. The chambers do not need to be removed from the heating block nor are the electrodes disturbed. The easy and rapid replacement of tissue samples makes the EasyMount system an excellent choice for high-throughput applications.
EasyMount systems are versatile and can be readily ganged together in series to allow for higher throughput, multi-chamber applications. They are compatible with any of our line of voltage/current clamps. They can be purchased in a variety of chamber and specific tissue holder configurations to meet most applications. If you require a custom chamber or would like information on selecting the chamber or tissue holder configuration that is most suited to your application, please call our Technical Support Department for assistance.


Specifications Back to Top

Specifications690969690970690971690972690973690974690975690976
ModelP2404P2405P2406P2407P2410P2411P2412P2413
Use with ChamberP2400P2400P2400P2400P2400P2400P2400P2400
Aperture2.8 x 9.2 mm4.5 x 9.2 mm2.8 x 1.5 mm2 mm Diameter5 mm Diameter6.2 mm Diameter8 mm Diameter9.5 mm Diameter
Area0.250.40.040.0310.20.30.50.71

Back to Top



Journal Articles Back to Top

Displaying 1 to 10 of 42results for Inserts for P2400 Low Volume EasyMount Diffusion Chambers   Page 1  2  3  4  5 

Score

Document

Description

100% Login to view AM19.pdf
[972 KB]
Laboratory comparison of polyethylene and dialysis membrane diffusion samplers
100% Login to view HS15 isolated heart app.pdf
[632 KB]
Isolated Heart Apparatus use in Myoglobin facilitating oxygen diffusion
85% Login to view VT06 Ventilator use in finding load as an acute determinant of end-diastolic pressure-volume relation.pdf
[200 KB]
h4Ventilator use in finding load as an acute determinant of end-diastolic pressure-volume relation010100051p
79% Login to view PP185.pdf
[191 KB]
Single-Molecule Tracing on a Fluidic Microchip for Quantitative Detection of Low-Abundance Nucleic Acids
70% Login to view PP35 Peristaltic Pump.pdf
[381 KB]
Peristaltic pump use in finding Improvements to parallel plate flow chambers to reduce reagent and cellular requirements
69% Login to view PP12 Pump 11 Syringe.pdf
[179 KB]
Syringe Pump use in Studies of potential-dependent metallothionein adsorptions using a low-volume electrochemical quartz crystal microbalance flow cell
53% Login to view Independence of extracellular tortuosity.pdf
[331 KB]
Independence of extracellular tortuosity and volume fraction during osmotic challenge in rat neocortex
37% Login to view HB06 homeothermic Blanket.pdf
[427 KB]
Neuroprotection and Neurotoxicity Studies in Rats with AHN649
35% Login to view PDMI07.pdf
[402 KB]
Diffusion of Tricarboxylic Acid Cycle Enzymes in the Mitochondrial Matrix in Vivo
35% Login to view HS15 Myoglobin facilitates oxygen diffusion.pdf
[631 KB]
Isolated Heart Apparatus use in Myoglobin facilitating oxygen diffusion
   

Back to Top



Manuals Back to Top

Displaying 1 to 1 of 1result for Inserts for P2400 Low Volume EasyMount Diffusion Chambers  

Score

Document

Description

100% Login to view Ussing Chamber Systems.pdf
[1.5 MB]
Guide to Ussing Chamber Systems
   

Back to Top

Breakthrough Products for Regenerative Medicine
2011 Regenerative Medicine Brochure
100's of Innovative products developed with leading scientists & surgeons!
  • Injection & Perfusion
  • Bioreactors
  • Biosensing
  • Total Solutions
  • Total Support


Announcing the new
PHD ULTRA™ Syringe Pumps

Click here for more information about PHD ULTRA™ Syringe Pumps and to download a brochure.

  • Patent pending mechanical design provides highest accuracy/precision & smoothest flow
  • Easy operation with advanced touch screen
  • Advanced EZ PRO™ software for PC functions without a PC.


Sign-up for a FREE Full Line Bioresearch Catalog
CLICK HERE!

  • Over 11,000 specialty products to enhance your bioresearch
  • Enhanced solutions for small animal research
  • 100's of pages of specialized information on instrumentation, applications, uses of products

 

Products on this website are for Research Use Only. Not for use in humans unless
proper investigational device regulations have been followed.


Privacy Policy   |   Terms and Conditions   
Copyright© Harvard Apparatus Ltd. - All rights reserved.
(44) 1223-423723
Website-related comments or concerns can be emailed to our webmaster.

Anesthesia Equipment Animal Handling Products Behavior Research Products Biological Measurement Products Cardiovascular Products Cell Biology Products Microincubation / Microinjectors CPK® Atomic Models Delivery & Sampling Products Dialysis / Sample Prep / SPE Electroporation / Transfection Electrophysiology Products General Laboratory Products Homeothermic/Temperature Control Isolated Organ & Isolated Tissue Molecular Biology Products Neuroscience Products Non-Invasive Blood Pressure Physiology Products Respiratory Products Stereotaxic Instruments Surgical Equipment Surgical Instruments Syringe Pumps/Peristaltic Pumps Tubing & Connectors Ventilators