Welcome to Harvard Apparatus UK! Login / Register
Search

Search for these keywords
Home Catalogs Online Technical Resources My Account
Advanced Search   
Products by Category

Featured Products
Warner Cell Electrophysiology & Cell Biology Research
Hugo Sachs Elektronic Isolated Organ and Tissue Systems
BTX Electroporation and Electrofusion Products
Panlab Behavior Research Products
Hoefer Electrophoresis Products
Coulbourn Instruments
Clark Glass Products
Navicyte Ussing/Diffusion Chambers
CMA
Harvard Apparatus
 

Home Panlab Treadmills


Larger Views

 

Panlab Treadmills

Panlab/Harvard Apparatus Treadmills are rolling belts with an adjustable speed and slope, enabling forced exercise training and accurate testing of fatigue in rodents. Different models are available depending on the user's needs from one to five lanes/animals.
Search for Product in current catalog
Item Listing Full Description Specifications
Item# Description
760303 Rat Single Lane Treadmill
760304 Mouse Single Lane Treadmill
760305 Rabbit Single Lane Treadmill
760306 Rat Double Lane Treadmill
760307 Mouse Double Lane Treadmill
760308 Rat 5-Lane Treadmill
760309 Mouse 5-Lane Treadmill

For local pricing, contact your nearest distributor.



Full Description Back to Top

• High performance motor
• Silent operation, even at high regimes
• Accurate control of the intensity of the shock delivered
• Computer interface included
• Negative slope available
• Easy to clean

Panlab/Harvard Apparatus Treadmills are rolling belts with an adjustable speed and slope, enabling forced exercise training and accurate testing of fatigue in rodents. Different models are available depending on the user's needs from one to five lanes/animals.

These Treadmills have an adjustable speed (up to 150 cm/s) and slope (from -25 to +25 degrees) and a control Unit. The rolling belt is built with specially selected materials to guarantee the best performance under conditions of intensive use and the minimum operations of maintenance, as well as simplicity in keeping it clean. The lanes (corridors of activity for the animal) have sufficient width for the subject to correct its errors in coordination, thereby allowing an exact measurement of the fatigue without deficiencies in motor coordination.

The unit controls the speed of the belt, shows measured data in its display, provides current to the shocking grid and allows communication with the PC for data storage, via the RS-232 output and SeDaCom software. Belt velocity can also be controlled by software. Parameters measured in a trial are: belt speed and slope, distance travelled, shock time, and shock intensity.

The electrical shock supplied by the grid is of constant intensity (from 0 to 2 mA), that is, the current which circulates through the animal (and therefore its effect) only depends on the value of the mA chosen and not of the subject (quantity of body mass in contact with the bars, perspiration, etc.)

The apparatus can optionally be provided with an air isolated enclosure for respiratory metabolism studies - single lane versions only.

Citations
Serradj N and Jamon M (2007) Age-related changes in the motricity of the inbred mice strains 129/sv and C57BL/6j. Behavioral Brain research 177(1): 80-89. (mouse, France)
Suelves M et al. (2007) uPA deficiency exacerbates muscular dystrophy in MDX mice. The Journal of Cell Biology 178(6):1039-51. (Mouse, Spain)
Alonso M et al. (2006) Melatonin inhibits the expression of the inducible isoform of nitric oxide synthase and nuclear factor kappa B activation in rat skeletal muscle. J. Pineal Res. In Press Billat V et al. (2005) Inter- and intrastrain variation in mouse critical running speed. J. Apll. Physiol. 98: 1258-1263. (mice, France).
Majczynski H et al. (2005) Serotonin-Related Enhancement of Recovery of Hind Limb Motor Functions in Spinal Rats after Grafting of Embryonic Raphe Nuclei. J. Neurotrauma. 22(5): 590-604. (Rat, Poland)


Specifications Back to Top

Specifications760303760304760305760306760307760308760309
Model NumberLE8700LE8708LE8715LE8706LE8709LE8710RLE8710M
Computer RequirementsWindows 95, 98, ME, NT, 2000, and XPWindows 95, 98, ME, NT, 2000, and XPWindows 95, 98, ME, NT, 2000, and XPWindows 95, 98, ME, NT, 2000, and XPWindows 95, 98, ME, NT, 2000, and XPWindows 95, 98, ME, NT, 2000, and XPWindows 95, 98, ME, NT, 2000, and XP
Catalog PagesG19-G20G19-G20G19-G20G19-G20G19-G20G19-G20G19-G20
Maximum Number of Stations1 per computer with SeDaCom or up to 10 with Tread-01 Software1 per computer with SeDaCom or up to 10 with Tread-01 Software1 per computer with SeDaCom or up to 10 with Tread-01 Software1 per computer with SeDaCom or up to 10 with Tread-01 Software1 per computer with SeDaCom or up to 10 with Tread-01 Software1 per computer with SeDaCom or up to 10 with Tread-01 Software1 per computer with SeDaCom or up to 10 with Tread-01 Software
Power Requirements110V or 220V, 50/60 Hz110V or 220V, 50/60 Hz110V or 220V, 50/60 Hz110V or 220V, 50/60 Hz110V or 220V, 50/60 Hz110V or 220V, 50/60 Hz110V or 220V, 50/60 Hz
CertificationCECECECECECECE
SeDaCom IncludedYesYesYesYesYesYesYes
Current RangeAdjustable from 0 to 2 mAAdjustable from 0 to 2 mAAdjustable from 0 to 2 mAAdjustable from 0 to 2 mAAdjustable from 0 to 2 mAAdjustable from 0 to 2 mAAdjustable from 0 to 2 mA
Belt SpeedAdjustable from 0 to 0.6 m/secAdjustable from 0 to 0.6 m/secAdjustable from 0 to 0.6 m/secAdjustable from 0 to 0.6 m/secAdjustable from 0 to 0.6 m/secAdjustable from 0 to 0.6 m/secAdjustable from 0 to 0.6 m/sec
Running Surface Length450 mm450 mm450 mm450 mm450 mm450 mm450 mm
Running Surface Width100 mm100 mm100 mm100 mm100 mm100 mm100 mm
Number of Running Lanes1112255
Shock GridYesYesYesYesYesYesYes
Shock Grid Length190 mm190 mm190 mm190 mm190 mm190 mm190 mm
Shock Grid Width100 mm100 mm100 mm100 mm100 mm100 mm100 mm
Slope Adjustment0 to 25ˇ - Negative Slope available upon request0 to 25ˇ - Negative Slope available upon request0 to 25ˇ - Negative Slope available upon request0 to 25ˇ - Negative Slope available upon request0 to 25ˇ - Negative Slope available upon request0 to 25ˇ - Negative Slope available upon request0 to 25ˇ - Negative Slope available upon request
Negative Slope OptionUpon RequestUpon RequestUpon RequestUpon RequestUpon RequestUpon RequestUpon Request
Shock RangeAdjustable from 0 to 2mAAdjustable from 0 to 2mAAdjustable from 0 to 2mAAdjustable from 0 to 2mAAdjustable from 0 to 2mAAdjustable from 0 to 2mAAdjustable from 0 to 2mA
Running Lanes1112255

Back to Top

Breakthrough Products for Regenerative Medicine
2011 Regenerative Medicine Brochure
100's of Innovative products developed with leading scientists & surgeons!
  • Injection & Perfusion
  • Bioreactors
  • Biosensing
  • Total Solutions
  • Total Support


Announcing the new
PHD ULTRA™ Syringe Pumps

Click here for more information about PHD ULTRA™ Syringe Pumps and to download a brochure.

  • Patent pending mechanical design provides highest accuracy/precision & smoothest flow
  • Easy operation with advanced touch screen
  • Advanced EZ PRO™ software for PC functions without a PC.


Sign-up for a FREE Full Line Bioresearch Catalog
CLICK HERE!

  • Over 11,000 specialty products to enhance your bioresearch
  • Enhanced solutions for small animal research
  • 100's of pages of specialized information on instrumentation, applications, uses of products

 

Products on this website are for Research Use Only. Not for use in humans unless
proper investigational device regulations have been followed.


Privacy Policy   |   Terms and Conditions   
Copyright© Harvard Apparatus Ltd. - All rights reserved.
(44) 1223-423723
Website-related comments or concerns can be emailed to our webmaster.

Anesthesia Equipment Animal Handling Products Behavior Research Products Biological Measurement Products Cardiovascular Products Cell Biology Products Microincubation / Microinjectors CPK® Atomic Models Delivery & Sampling Products Dialysis / Sample Prep / SPE Electroporation / Transfection Electrophysiology Products General Laboratory Products Homeothermic/Temperature Control Isolated Organ & Isolated Tissue Molecular Biology Products Neuroscience Products Non-Invasive Blood Pressure Physiology Products Respiratory Products Stereotaxic Instruments Surgical Equipment Surgical Instruments Syringe Pumps/Peristaltic Pumps Tubing & Connectors Ventilators