Plethysmographs for PowerLab
The IR Plethysmographs use an infrared photoelectric sensor to detect changes in tissue blood volume. The MLT1020PPG features a velcro strap, the MLT1060EC has a spring clip suitable for readings from a finger or toe and the MLT1020EC features an ear clip. The IR Plethysmographs can be connected to any Bridge Amp, or directly to a Pod port of a PowerLab.
The IR Plethysmographs use an infrared photoelectric sensor to detect changes in tissue blood volume. The MLT1020PPG features a velcro strap, the MLT1020FC has a spring clip suitable for readings from a finger or toe and the MLT1020EC features an ear clip. The IR Plethysmographs can be connected to the ML110 Bridge Amp, ML112 Quad Bridge Amp, ML142 GP Amp, or directly to a Pod port of a PowerLab.
Operation
The velcro strap and finger clip models use reflected infrared light and work best where the light can reflect from the bone beneath the tissue. They are especially good for the finger or forehead (directly over the centre of the eyebrow is an excellent location). The ear clip, on the other hand, uses infrared light transmitted through the tissue, and so works best on fleshy areas such as the earlobe. The amplitude of the signal depends primarily on the volume of blood in the capillary bed directly beneath the sensor, so it may be necessary to move the sensor around to find the best signal. The clips should attach to fleshy areas with no problems. When using the model with the Velcro strap to attach to a finger or toe, take care that the strap is firm, but not so tight as to restrict blood flow. If you are taking measurements where the Velcro strap is too short to be useful (such as from the leg or head), then you can lightly wrap an elastic bandage around the sensor and body part to hold the sensor in place. Ambient light may affect the output: if it does, a covering of black, opaque material over the sensor and location should remove such interference. Note: The IR Plethysmographs are normally used with AC coupling in the Input Amplifier dialog box (in LabChart software) turned on.
Application
The IR Plethysmographs can be used to record changes in blood volume as the arterial pulse expands and contracts the microvasculature.
Specifications | 77-0293 | 77-0071 | 77-0072 |
---|---|---|---|
Connector | 8-pin DIN | 8-pin DIN | 8-pin DIN |
Excitation | 6 to 9 V DC | 6 to 9 V DC | 6 to 9 V DC |
Model | MLT1060EC | MLT1020FC | MLT1020PPG |
Output Impedance | 1 kΩ nominal | 1 kΩ nominal | 1 kΩ nominal |
Output | 5 to 50 mV (typical finger application at rest) | 5 to 50 mV (typical finger application at rest) | 5 to 50 mV (typical finger application at rest) |
Package | 1 | 1 | 1 |
Product Family | Data Acquisition | Data Acquisition | Data Acquisition |
Sensor Size English | 0.6 x 0.6 x 0.24 in | 0.6 x 0.6 x 0.24 in | 0.6 x 0.6 x 0.24 in |
Sensor Size Metric | 15 x 15 x 6.3 mm | 15 x 15 x 6.3 mm | 15 x 15 x 6.3 mm |
Wavelength | 950 nm | 950 nm | 950 nm |
Weight | 8 g | 8 g | 8 g |